Rapid in vivo musculoskeletal MR with parallel imaging at 7T

被引:35
作者
Banerjee, Suchandrima [1 ,2 ]
Krug, Roland [1 ]
Carballido-Gamio, Julio [1 ]
Kelley, Douglas A. C.
Xu, Duan [1 ]
Vigneron, Daniel B. [1 ,2 ]
Majumdar, Sharmila [1 ,2 ]
机构
[1] Univ Calif San Francisco, San Francisco, CA 94158 USA
[2] Univ Calif Berkeley, Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
关键词
7; Tesla; GRAPPA; trabecular bone micro-architecture; cartilage;
D O I
10.1002/mrm.21455
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work was to implement autocalibrating GRAPPA-based parallel imaging (PI) for in vivo high-resolution (HR) MRI of cartilage and trabecular bone micro-architecture at 7T and to evaluate its performance based on comparison of MR-derived morphology metrics between accelerated and conventional images and comparison of geometry factor measures between 3T and 7T. Using an eight channel coil array for trabecular MRI at the ankle, a higher maximum feasible acceleration (R) = 6 and lower geometry factor values than that at 3T were observed. The advantages of two-dimensional acceleration were also demonstrated. In knee cartilage and bone acquisitions, feasibility of PI with a dual-channel quadrature coil was investigated. Robust quantification of bone and cartilage metrics could be derived from accelerated ankle and knee acquisitions. PI can enhance the clinical feasibility of in vivo bone and cartilage HR-MRI for osteoporosis and osteoarthritis at 7T.
引用
收藏
页码:655 / 660
页数:6
相关论文
共 24 条
[1]   Transmit and receive transmission line arrays for 7 tesla parallel imaging [J].
Adriany, G ;
Van de Moortele, PF ;
Wiesinger, F ;
Moeller, S ;
Strupp, JP ;
Andersen, P ;
Snyder, C ;
Zhang, XL ;
Chen, W ;
Pruessmann, KP ;
Boesiger, P ;
Vaughan, T ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) :434-445
[2]   Autocalibrating parallel imaging of in vivo trabecular bone micro architecture at 3 Tesla [J].
Banerjee, S. ;
Choudhury, S. ;
Han, E. T. ;
Brau, A. C. S. ;
Morze, C. V. ;
Vigneron, D. B. ;
Majumdar, S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (05) :1075-1084
[3]   Application of refocused steady-state free-precession methods at 1.5 and 3 T to in vivo high-resolution MRI of trabecular bone: Simulations and experiments [J].
Banerjee, S ;
Han, ET ;
Krug, R ;
Newitt, DC ;
Majumdar, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (06) :818-825
[4]  
BANERJEE S, 2007, P 15 ANN M ISMRM BER
[5]  
BANERJEE S, 2007, IN PRESS MAGN RESON
[6]  
BANERJEE S, 2007, P 15 ANN M ISMRM
[7]   Analysis of multiple-acquisition SSFP [J].
Bangerter, NK ;
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Gold, GE ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1038-1047
[8]  
CARBALLIDOGAMIO J, 2005, IEEE EMBS SHANGHAI, P3043
[9]  
CARBALLIDOGAMIO J, 2005, ISMRM, P1988
[10]  
CASSELMAN JW, 1993, AM J NEURORADIOL, V14, P47