PERFORMANCE EVALUATION OF DRY EYE DETECTION SYSTEM USING HIGHER-ORDER SPECTRA FEATURES FOR DIFFERENT NOISE LEVELS IN IR THERMAL IMAGES

被引:7
作者
Sudarshan, Vidya K. [1 ,2 ]
Koh, Joel E. W. [3 ]
Tan, Jen Hong [3 ]
Hagiwara, Yuki [3 ]
Chua, Kuang Chua [3 ]
Ng, Eddie Y. K. [4 ]
Tong, Louis [5 ,6 ,7 ,8 ]
机构
[1] Singapore Univ Social Sci, Sch Sci & Technol, Dept Biomed Engn, Singapore 599491, Singapore
[2] Univ Newcastle, Sch Elect & Comp Engn, Singapore 038986, Singapore
[3] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[4] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[5] Singapore Eye Res Inst, Singapore 168751, Singapore
[6] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[7] Duke NUS Grad Med Sch, Singapore 169857, Singapore
[8] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117597, Singapore
关键词
Dry eye; HOS; bispectrum; cumulants; IR thermal images; INFRARED THERMOGRAPHY IMAGES; DISCRETE WAVELET TRANSFORM; OCULAR SURFACE-TEMPERATURE; RATE-VARIABILITY SIGNALS; FATTY LIVER-DISEASE; HEART-RATE SIGNALS; AUTOMATED DETECTION; NONLINEAR FEATURES; INTEGRATED INDEX; DIAGNOSIS;
D O I
10.1142/S0219519417400103
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The enhanced tear film evaporation and diminished tear production causes a dry eye (DE) condition. A non-invasive infrared (IR) thermography is most commonly used as a diagnostic tool for diagnosis of DE. However, the availability of high-quality IR thermal camera at low cost is difficult. Hence, an efficient DE detection system which can perform efficiently by using low-cost and low-quality images instead of conventional IR images would be a significant contribution. Therefore, in this work, we have evaluated the performance of automated noninvasive DE detection system using low-quality images obtained by adding different levels of noise to high-quality IR images. In this work, the performances of two non-linear higher-order spectra (HOS) cumulants and bispectrum features are compared. These features are extracted from the IR images with different levels of Gaussian noise. Principal component analysis (PCA) is performed on these extracted features and they are ranked using t-value and later fed to different classifiers. We have achieved the accuracies, sensitivities and specificities of: (i) 86.90%, 85.71% and 88.10%, with noise level 0 using 24 bispectrum features, and (ii) 80.95%, 85.71% and 76.19%, with noise level 10 using 15 bispectrum features for right eye IR images. This study exhibits that even in the presence of high levels of noise, the detection of DE is possible and our proposed method performs efficiently using HOS bispectrum features. Thus, our proposed method can be used to detect DE using low-quality and inexpensive cameras instead of high-cost IR camera.
引用
收藏
页数:24
相关论文
共 64 条
[1]   Symptomatic vs. Asymptomatic Plaque Classification in Carotid Ultrasound [J].
Acharya, Rajendra U. ;
Faust, Oliver ;
Alvin, A. P. C. ;
Sree, S. Vinitha ;
Molinari, Filippo ;
Saba, Luca ;
Nicolaides, Andrew ;
Suri, Jasjit S. .
JOURNAL OF MEDICAL SYSTEMS, 2012, 36 (03) :1861-1871
[2]   Study of heart rate variability signals at sitting and lying postures [J].
Acharya, Rajendra U. ;
Kannathal, N. ;
Hua, Lee Mei ;
Yi, Leong Mei .
JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2005, 9 (02) :134-141
[3]   Cost-Effective and Non-Invasive Automated Benign & Malignant Thyroid Lesion Classification in 3D Contrast-Enhanced Ultrasound Using Combination of Wavelets and Textures: A Class of ThyroScan™ Algorithms [J].
Acharya, U. R. ;
Faust, O. ;
Sree, S. V. ;
Molinari, F. ;
Garberoglio, R. ;
Suri, J. S. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (04) :371-380
[4]   A novel algorithm to detect glaucoma risk using texton and local configuration pattern features extracted from fundus images [J].
Acharya, U. Rajendra ;
Bhat, Shreya ;
Koh, Joel E. W. ;
Bhandary, Sulatha V. ;
Adeli, Hojjat .
COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 88 :72-83
[5]   Automated detection of arrhythmias using different intervals of tachycardia ECG segments with convolutional neural network [J].
Acharya, U. Rajendra ;
Fujita, Hamido ;
Lih, Oh Shu ;
Hagiwara, Yuki ;
Tan, Jen Hong ;
Adam, Muhammad .
INFORMATION SCIENCES, 2017, 405 :81-90
[6]   Automated diabetic macular edema (DME) grading system using DWT, DCT Features and maculopathy index [J].
Acharya, U. Rajendra ;
Mookiah, Muthu Rama Krishnan ;
Koh, Joel E. W. ;
Tan, Jen Hong ;
Bhandary, Sulatha V. ;
Rao, A. Krishna ;
Hagiwara, Yuki ;
Chua, Chua Kuang ;
Laude, Augustinus .
COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 84 :59-68
[7]   Automated characterization of fatty liver disease and cirrhosis using curvelet transform and entropy features extracted from ultrasound images [J].
Acharya, U. Rajendra ;
Raghavendra, U. ;
Fujita, Hamido ;
Hagiwara, Yuki ;
Koh, Joel E. W. ;
HongTan, Jen ;
Sudarshan, Vidya K. ;
Vijayananthan, Anushya ;
Yeong, Chai Hong ;
Gudigar, Anjan ;
Ng, Kwan Hoong .
COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 79 :250-258
[8]   Automated screening system for retinal health using bi-dimensional empirical mode decomposition and integrated index [J].
Acharya, U. Rajendra ;
Mookiah, Muthu Rama Krishnan ;
Koh, Joel E. W. ;
Tan, Jen Hong ;
Bhandary, Sulatha V. ;
Rao, A. Krishna ;
Fujita, Hamido ;
Hagiwara, Yuki ;
Chua, Chua Kuang ;
Laude, Augustinus .
COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 75 :54-62
[9]   Novel risk index for the identification of age-related macular degeneration using radon transform and DWT features [J].
Acharya, U. Rajendra ;
Mookiah, Muthu Rama Krishnan ;
Koh, Joel E. W. ;
Tan, Jen Hong ;
Noronha, Kevin ;
Bhandary, Sulatha V. ;
Rao, A. Krishna ;
Hagiwara, Yuki ;
Chua, Chua Kuang ;
Laude, Augustinus .
COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 73 :131-140
[10]   A Novel Depression Diagnosis Index Using Nonlinear Features in EEG Signals [J].
Acharya, U. Rajendra ;
Sudarshan, Vidya K. ;
Adeli, Hojjat ;
Santhosh, Jayasree ;
Koh, Joel E. W. ;
Puthankatti, Subha D. ;
Adeli, Amir .
EUROPEAN NEUROLOGY, 2015, 74 (1-2) :79-83