The Effect of Corneal Wavefront Aberrations on Corneal Pseudoaccommodation

被引:18
作者
Yeu, Elizabeth [1 ]
Wang, Li [1 ]
Koch, Douglas D. [1 ]
机构
[1] Baylor Coll Med, Dept Ophthalmol, Cullen Eye Inst, Houston, TX 77030 USA
关键词
CHAMBER INTRAOCULAR LENSES; DEPTH-OF-FIELD; APPARENT ACCOMMODATION; PSEUDOPHAKIC EYES; VISUAL-ACUITY; IMPLANTATION; PRESBYOPIA; MYOPIA; FOCUS; ERROR;
D O I
10.1016/j.ajo.2011.10.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine the effect on corneal pseudoaccommodation of anterior corneal wavefront aberrations in normal corneas and corneas with prior myopic or hyperopic photorefractive keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK). DESIGN: Theoretical study. METHODS: In 220 normal eyes, 102 myopic-PRK eyes, and 106 hyperopic-LASIK/PRK eyes, anterior corneal higher-order aberrations (HOAs, third to sixth order, 6- and 4-mm pupils) were computed from the Atlas corneal elevation data using the VOL-CT program. Using the ZernikeTool, corneal optical image quality was evaluated by the polychromatic modulation transfer function with Stiles-Crawford effect. Defocus from -3.0 diopters (D) to +3.0 D was added to corneal HOAs, and depth of focus was defined as the ranges over which the polychromatic modulation transfer function maintains 80% of the peak value (DOF80) and 50% of the peak value (DOF50). The depth of focus values between groups were compared, stepwise multiple regression was used to assess if any Zernike terms significantly contributed to the depth of focus, and correlation analysis was performed to evaluate the correlation between depth of focus and corneal HOAs. RESULTS: The depth of focus varied widely between corneas, especially in corneas with prior hyperopic-LASIK/PRK. For 6-mm pupil, mean depth of focus values in myopic-PRK and hyperopic-LASIK/PRK corneas were significantly greater than those for normal corneas, and for 4-mm pupil, depth of focus values in hyperopic-LASIK/PRK corneas were greater than those in normal and myopic-PRK corneas. Zernike terms significantly contributing to both DOF80 and DOF50 were fourth- and sixth-order spherical aberration and fourth- and sixth-order astigmatism in normal corneas, third-order vertical coma and fourth-order tetrafoil in myopic-PRK corneas, and third-order vertical coma and fourth-order astigmatism in hyperopic-LASIK/PRK corneas. Depth of focus had weak to moderate positive correlation with HOAs (Pearson correlation coefficient r ranged from 0.300 to 0.583). CONCLUSION: These theoretical calculations suggest that certain corneal wavefront aberrations affect corneal pseudoaccommodation. To predict corneal pseudoaccommodation, the most important Zernike term is spherical aberration in normal eyes and coma in eyes with prior laser corneal surgery. (Am J Ophthalmol 2012;153: 972-981. (C) 2012 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:972 / 981
页数:10
相关论文
共 15 条
  • [1] Visual acuity as a function of Zernike mode and level of root mean square error
    Applegate, RA
    Ballentine, C
    Gross, H
    Sarver, EJ
    Sarver, CA
    [J]. OPTOMETRY AND VISION SCIENCE, 2003, 80 (02) : 97 - 105
  • [2] Evidence for delayed presbyopia after photorefractive keratectomy for myopia
    Artola, A
    Patel, S
    Schimchak, P
    Ayala, MJ
    Ruiz-Moreno, JM
    Alió, JL
    [J]. OPHTHALMOLOGY, 2006, 113 (05) : 735 - 741
  • [3] Optical surface optimization for the correction of presbyopia
    Dai, Guang-Ming
    [J]. APPLIED OPTICS, 2006, 45 (17) : 4184 - 4195
  • [4] Relationship between apparent accommodation and corneal multifocality in pseudophakic eyes
    Fukuyama, M
    Oshika, T
    Amano, S
    Yoshitomi, F
    [J]. OPHTHALMOLOGY, 1999, 106 (06) : 1178 - 1181
  • [5] Huber C, 1981, J Am Intraocul Implant Soc, V7, P244
  • [6] TOLERANCE TO VISUAL DEFOCUS
    LEGGE, GE
    MULLEN, KT
    WOO, GC
    CAMPBELL, FW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05) : 851 - 863
  • [7] Marcos S, 2005, J REFRACT SURG, V21, P223
  • [8] The depth-of-field of the human eye from objective and subjective measurements
    Marcos, S
    Moreno, E
    Navarro, R
    [J]. VISION RESEARCH, 1999, 39 (12) : 2039 - 2049
  • [9] APPARENT ACCOMMODATION IN PSEUDOPHAKIC EYES AFTER IMPLANTATION OF POSTERIOR CHAMBER INTRAOCULAR LENSES
    NAKAZAWA, M
    OHTSUKI, K
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 96 (04) : 435 - 438
  • [10] NAKAZAWA M, 1984, INVEST OPHTH VIS SCI, V25, P1458