Accuracy of electronic apex locators in comparison to actual length - an in vivo study

被引:52
作者
Haffner, C
Folwaczny, M
Galler, K
Hickel, R
机构
[1] Univ Munich, Dept Restorat Dent, D-80336 Munich, Germany
[2] Univ Regensburg, Dept Restorat Dent, D-93042 Regensburg, Germany
关键词
working length; endodontic; measurement precision; determination; apical foramen;
D O I
10.1016/j.jdent.2004.11.017
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The measurement precision of four electronic apex locators (Root ZX, Morita, Tokyo, Japan; Endy, Loser, Leverkusen, Germany; Justy II, Hager-Werken, Duisburg, Germany; Endox Lysis, Milan, Italy) was examined in the present in vivo study. Methods: The root canal length of 40 single-rooted and multi-rooted teeth was determined with the four devices prior to tooth extraction. To determine the actual root canal length, the apical third was longitudinally sectioned, the root canal instrument was positioned and the apex was examined using a microscope. Results: The average measurement deviation ( +/- SD) in relation to the apical constriction was 0.3mm ( +/- 0.6) for the Root ZX, 0.7mm ( +/- 1.0) for the Endy, 0.2 mm ( +/- 0.7) for the Justy II and 1.3 mm (+/- 1.7) for the Endox. The limit of +/- 0.5 mm from the apical constriction was attained by the Root ZX in 78%, by the Endy in 67%, by the Justy II in 80% and by Endox in 31% of all measurements. Conclusions: The Latest generation of apex locaters provide the clinician with an accurate and useful adjunct for the determination of root canal length. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:619 / 625
页数:7
相关论文
共 29 条
[1]  
[Anonymous], 1998, Essential endodontology
[2]   AN IN-VIVO EVALUATION OF THE ENDEX(ASTERISK) AND RCM MARK-II ELECTRONIC APEX LOCATORS IN ROOT CANALS WITH DIFFERENT CONTENTS [J].
ARORA, RK ;
GULABIVALA, K .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1995, 79 (04) :497-503
[3]   CRITICAL EVALUATION OF SOME METHODS OF DETERMINING TOOTH LENGTH [J].
BRAMANTE, CM ;
BERBERT, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1974, 37 (03) :463-473
[4]   An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals [J].
Dunlap, CA ;
Remeikis, NA ;
BeGole, EA ;
Rauschenberger, CR .
JOURNAL OF ENDODONTICS, 1998, 24 (01) :48-50
[5]   RADIOGRAPHIC REPRODUCTION OF ENDODONTIC WORKING LENGTH COMPARING THE PARALLELING AND THE BISECTING-ANGLE TECHNIQUES [J].
FORSBERG, J .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1987, 64 (03) :353-360
[6]   A CLINICAL-EVALUATION OF 5 ELECTRONIC ROOT-CANAL LENGTH MEASURING-INSTRUMENTS [J].
FOUAD, AF ;
KRELL, KV ;
MCKENDRY, DJ ;
KOORBUSCH, GF ;
OLSON, RA .
JOURNAL OF ENDODONTICS, 1990, 16 (09) :446-449
[7]   AN INVITRO COMPARISON OF 5 ROOT-CANAL LENGTH MEASURING-INSTRUMENTS [J].
FOUAD, AF ;
KRELL, KV .
JOURNAL OF ENDODONTICS, 1989, 15 (12) :573-577
[8]   ENDODONTIC SUCCESS - WHOS READING RADIOGRAPH [J].
GOLDMAN, M ;
DARZENTA, N ;
PEARSON, AH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1972, 33 (03) :432-&
[9]  
Gutmann J L, 1995, Compend Contin Educ Dent, V16, P293