DiaPat urine test for prostate cancer. Predictive value for results of transrectal ultrasound-guided prostate biopsies

被引:0
作者
Oberpenning, F. [2 ]
von Knobloch, R. [3 ]
Sprute, W. [4 ]
Roth, S. [5 ]
Rathert, M. [5 ]
Bierer, S. [1 ]
Gerss, J. [6 ]
Semjonow, A. [1 ]
机构
[1] Univ Klinikum, Prostatazentrum, Klin & Poliklin Urol, D-48129 Munster, Germany
[2] St Agnes Hosp, Klin Urol & Kinderurol, Bocholt, Germany
[3] Franziskus Hosp, Urol Klin, Prostatazentrum, Bielefeld, Germany
[4] Facharzt Urol, Hamm, Germany
[5] HELIOS Klin, Klin Urol & Kinderurol, Wuppertal, Germany
[6] Univ & Univ Klinikum, Inst Med Informat & Biomath, Munster, Germany
来源
UROLOGE | 2008年 / 47卷 / 06期
关键词
capillary electrophoresis; mass spectrometry; prostate cancer; proteomics; urine;
D O I
10.1007/s00120-008-1767-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background. A novel urine test for early detection of prostate cancer (PCA), distributed and marketed by the company DiaPat, is advertised by the statement "correct analysis in 9 of 10 cases." Patients and methods. The test separates urinary polypeptides by means of capillary electrophoresis and characterizes the peptides in a time-of-flight mass spectrometer. The DiaPat test was performed on the urine of 18 men prior to multiple ultrasound-guided prostate biopsies. Results. Sixteen of the 18 samples met the requirements for sample quality as established by the manufacturer. Eight of these 16 urine samples had been collected from patients in whom biopsies consecutively detected PCA; the remaining eight patients had benign biopsy results. Among the eight patients with detected PCA, the urine test yielded a low probability for PCA in three cases and a high probability in five. Within the group of eight patients with benign biopsy results, the urine test predicted a high probability for PCA in five men and a low probability in three. For the given PCA incidence of 50% within the investigated population, the DiaPat test correctly predicted biopsy results in one half of the population, whereas prediction in the remaining half was incorrect. Conclusion. Unless reliable validation of the DiaPat urine test for PCA is available, no clinical consequences should be drawn from the test results.
引用
收藏
页码:735 / 739
页数:5
相关论文
共 8 条
[1]   REFINING BINOMIAL CONFIDENCE-INTERVALS [J].
CASELLA, G .
CANADIAN JOURNAL OF STATISTICS-REVUE CANADIENNE DE STATISTIQUE, 1986, 14 (02) :113-129
[2]  
Clopper CJ, 1934, BIOMETRIKA, V26, P404, DOI 10.2307/2331986
[3]   Introduction to Bayesian methods I: measuring the strength of evidence [J].
Goodman, SN .
CLINICAL TRIALS, 2005, 2 (04) :282-290
[4]  
Semjonow A, 2007, UROLOGE, V46, P1428, DOI 10.1007/s00120-007-1532-1
[5]   Pilot study of capillary electrophoresis coupled to mass spectrometry as a tool to define potential prostate cancer biomarkers in urine [J].
Theodorescu, D ;
Fliser, D ;
Wittke, S ;
Mischak, H ;
Krebs, R ;
Walden, M ;
Ross, M ;
Eltze, E ;
Bettendorf, O ;
Wulfing, C ;
Semjonow, A .
ELECTROPHORESIS, 2005, 26 (14) :2797-2808
[6]   Discovery and validation of urinary biomarkers for propstate cancer [J].
Theodorescu, Dan ;
Schiffer, Eric ;
Bauer, Hartwig W. ;
Douwes, Friedrich ;
Eichhorn, Frank ;
Polley, Reinhard ;
Schmidt, Thomas ;
Schoefer, Wolfgang ;
Zuerbig, Petra ;
Good, David M. ;
Coon, Joshua J. ;
Mischak, Harald .
PROTEOMICS CLINICAL APPLICATIONS, 2008, 2 (04) :556-570
[7]  
Wittekind C., 2002, TNM KLASSIFIKATION M
[8]   Capillary electrophoresis coupled to mass spectrometry for proteome analysis. An innovative diagnostic method for prostate and bladder cancer [J].
Wittke, S. ;
Schiffer, E. ;
Bauer, H. W. .
UROLOGE, 2007, 46 (07) :733-739