Use of Multispectral MRI to Monitor Aneurysm Sac Contents After Endovascular Abdominal Aortic Aneurysm Repair

被引:8
作者
Cornelissen, Sandra A. [1 ]
van der Laan, Maarten J. [2 ]
Vincken, Koen L. [1 ]
Vonken, Evert-Jan P. A. [1 ]
Viergever, Max A. [1 ]
Bakker, Chris J. [1 ]
Moll, Frans L. [3 ]
Bartels, Lambertus W. [1 ]
机构
[1] UMC Utrecht, Dept Radiol, Image Sci Inst, Utrecht, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Surg, NL-1105 AZ Amsterdam, Netherlands
[3] UMC Utrecht, Dept Vasc Surg, Utrecht, Netherlands
关键词
endovascular aneurysm repair; aortic aneurysm; magnetic resonance imaging; aneurysm sac; surveillance; repeatability; POOL CONTRAST AGENT; COMPUTED-TOMOGRAPHY; ENDOLEAK DETECTION; STENT-GRAFTS; FOLLOW-UP; ANGIOGRAPHY; SURVEILLANCE; CT;
D O I
10.1583/10-3271.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To validate a newly developed semi-automatic multispectral magnetic resonance imaging (MRI) tool for quantitatively monitoring aneurysm sac contents in patients after endovascular aneurysm repair (EVAR). Methods: MRI studies from 24 EVAR patients were retrospectively analyzed. The precontrast T(1)-weighted and T(2)-weighted and the postcontrast T1-weighted images were displayed simultaneously. Two independent observers classified the aneurysm sac voxels into categories for endoleak, unorganized thrombus, or organized thrombus by interactively thresholding the multispectral images relative to the signal intensity of fat. Voxel classification was visualized as a color overlay on the MR images; when the observer changed the thresholds, the color overlay was updated immediately. The volumes of the voxels in each category were calculated and expressed in milliliters. The intra-and interobserver variability for measuring the volumes of endoleak and unorganized and organized thrombus were calculated; a Bland and Altman analysis was applied to determine the mean differences and the repeatability coefficient (RC). Results: Mean aneurysm sac volume was 78 +/- 42 mL. The intraobserver mean difference for the endoleak volume was 0.5 +/- 1.9 mL with an RC of 3.7 mL; the interobserver mean difference was -0.8 +/- 3.6 mL (RC 7.1 mL). The intraobserver mean difference for unorganized thrombus volume was -1.2 +/- 4.4 mL (RC 8.6 mL); the interobserver mean difference was 0.3 +/- 6.3 mL with an RC of 12.3 mL. The intraobserver mean difference for organized thrombus volume was 0.8 +/- 5.0 mL (RC 9.7 mL); the interobserver mean difference was 0.4 +/- 6.3 mL (RC 12.4 mL). Conclusion: Reproducible monitoring of aneurysm sac contents in EVAR patients is feasible with multispectral MRI in combination with our semi-automatic post-processing tool. J Endovasc Ther. 2011; 18: 274-279
引用
收藏
页码:274 / 279
页数:6
相关论文
共 24 条
[1]   Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms [J].
Alerci, Mario ;
Oberson, Michel ;
Fogliata, Antonella ;
Gallino, Augusto ;
Vock, Peter ;
Wyttenbach, Rolf .
EUROPEAN RADIOLOGY, 2009, 19 (05) :1223-1231
[2]   MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses [J].
Ayuso, JR ;
de Caralt, TM ;
Pages, M ;
Riambau, V ;
Ayuso, C ;
Sanchez, M ;
Real, MI ;
Montaña, X .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :803-810
[3]  
Bakken Andrew M, 2010, Perspect Vasc Surg Endovasc Ther, V22, P145, DOI 10.1177/1531003510382664
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   MURAL THROMBI IN ABDOMINAL AORTIC-ANEURYSMS - MR-IMAGING CHARACTERIZATION-USEFUL BEFORE ENDOVASCULAR TREATMENT [J].
CASTRUCCI, M ;
MELLONE, R ;
VANZULLI, A ;
DEGASPARI, A ;
CASTELLANO, R ;
ASTORE, D ;
CHIESA, R ;
GROSSI, A ;
DELMASCHIO, A .
RADIOLOGY, 1995, 197 (01) :135-139
[6]   MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms [J].
Cejna, M ;
Loewe, C ;
Schoder, M ;
Dirisamer, A ;
Hölzenbein, T ;
Kretschmer, G ;
Lammer, J ;
Thurnher, S .
EUROPEAN RADIOLOGY, 2002, 12 (10) :2443-2450
[7]   Visualizing type IV endoleak using magnetic resonance imaging with a blood pool contrast agent [J].
Cornelissen, Sandra A. ;
Verhagen, Hence J. ;
Prokop, Mathias ;
Moll, Frans L. ;
Bartels, Lambertus W. .
JOURNAL OF VASCULAR SURGERY, 2008, 47 (04) :861-864
[8]   Detection of Occult Endoleaks After Endovascular Treatment of Abdominal Aortic Aneurysm Using Magnetic Resonance Imaging With a Blood Pool Contrast Agent Preliminary Observations [J].
Cornelissen, Sandra A. P. ;
Prokop, Mathias ;
Verhagen, Hence J. ;
Adriaensen, Miraude E. ;
Moll, Frans L. ;
Bartels, Lambertus W. .
INVESTIGATIVE RADIOLOGY, 2010, 45 (09) :548-553
[9]   Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms [J].
Engellau, L ;
Larsson, EM ;
Albrechtsson, U ;
Jonung, T ;
Ribbe, E ;
Thorne, J ;
Zdanowski, Z ;
Norgren, L .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) :212-219
[10]   Original report - Blood pool MR angiography of aortic stent-graft endoleak [J].
Ersoy, H ;
Jacobs, P ;
Kent, CK ;
Prince, MR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) :1181-1186