A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition

被引:18
作者
Kim, H. [1 ]
Chen, C. -T. [1 ]
Eclov, N. [1 ]
Ronzhin, A. [2 ]
Murat, P. [2 ]
Ramberg, E. [2 ]
Los, S. [2 ]
Wyrwicz, A. M. [3 ]
Li, L. [3 ]
Kao, C. -M. [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[3] NorthShore Univ HealthSyst Res Inst, Evanston, IL 60201 USA
关键词
PET-MRI; Strip-line signal readout; Waveform sampling; TOF-PET DETECTOR; SILICON; PERFORMANCES;
D O I
10.1016/j.nima.2014.12.080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We are developing a time-of-flight Positron Emission Tomography (PET) detector by using silicon photo-multipliers (SiPM) on a strip-line and high speed waveform sampling data acquisition. In this design, multiple SiPMs are connected on a single strip-line and signal waveforms on the strip-line are sampled at two ends of the strip to reduce readout channels while fully exploiting the fast time response of SiPMs. In addition to the deposited energy and time information, the position of the hit SiPM along the strip-line is determined by the arrival time difference of the waveform. Due to the insensitivity of the SiPMs to magnetic fields and the compact front-end electronics, the detector approach is highly attractive for developing a PET insert system for a magnetic resonance imaging (MRI) scanner to provide simultaneous PET/MR imaging. To investigate the feasibility, experimental tests using prototype detector modules have been conducted inside a 9.4 T small animal MRI scanner (Bruker BioSpec 94/30 imaging spectrometer). On the prototype strip-line board, 16 SiPMs (5.2 mm pitch) are installed on two strip-lines and coupled to 2 x 8 LYSO scintillators (5.0 x 5.0 x 10.0 mm(3) with 5.2 mm pitch). The outputs of the strip-line boards are connected to a Domino-Ring-Sampler (DRS4) evaluation board for waveform sampling. Preliminary experimental results show that the effect of interference on the MRI image due to the PET detector is negligible and that PET detector performance is comparable with the results measured outside the MRI scanner. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:557 / 564
页数:8
相关论文
共 14 条
[1]   Status report on silicon photomultiplier development and its applications [J].
Dolgoshein, B. ;
Balagura, V. ;
Buzhan, P. ;
Danilov, M. ;
Filatov, L. ;
Garutti, E. ;
Groll, M. ;
Ilyin, A. ;
Kantserov, V. ;
Kaplin, V. ;
Karakash, A. ;
Kayumov, F. ;
Klemin, S. ;
Korbel, V. ;
Meyer, H. ;
Mizuk, R. ;
Morgunov, V. ;
Novikov, E. ;
Pakhlov, P. ;
Popova, E. ;
Rusinov, V. ;
Sefkow, F. ;
Tarkovsky, E. ;
Tikhomirov, I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (02) :368-376
[2]   The design and implementation of FFTW3 [J].
Frigo, M ;
Johnson, SG .
PROCEEDINGS OF THE IEEE, 2005, 93 (02) :216-231
[3]   A fast preamplifier concept for SiPM-based time-of-flight PET detectors [J].
Huizenga, J. ;
Seifert, S. ;
Schreuder, F. ;
van Dam, H. T. ;
Dendooven, P. ;
Lohner, H. ;
Vinke, R. ;
Schaart, D. R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 :379-384
[4]   A new time calibration method for switched-capacitor-array-based waveform samplers [J].
Kim, H. ;
Chen, C. -T. ;
Eclov, N. ;
Ronzhin, A. ;
Murat, P. ;
Ramberg, E. ;
Los, S. ;
Moses, W. ;
Choong, W. -S. ;
Kao, C. -M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 767 :67-74
[5]   A prototype TOF PET detector module using a micro-channel plate photomultiplier tube with waveform sampling [J].
Kim, H. ;
Chen, C. -T. ;
Frisch, H. ;
Tang, F. ;
Kao, C. -M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 662 (01) :26-32
[6]  
Kim H, 2012, IEEE NUCL SCI CONF R, P2466
[7]  
Kim H, 2013, IEEE S MASS STOR SYS
[8]   Recent developments in PET detector technology [J].
Lewellen, Tom K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :R287-R317
[9]   Electro-Optical Performances of p-on-n and n-on-p Silicon Photomultipliers [J].
Mazzillo, Massimo ;
Ronzhin, Anatoly ;
Los, Sergey ;
Abbisso, Salvatore ;
Sanfilippo, Delfo ;
Valvo, Giusy ;
Carbone, Beatrice ;
Piana, Angelo ;
Fallica, Giorgio ;
Albrow, Michael ;
Ramberg, Erik .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2012, 59 (12) :3419-3425
[10]   Timing Performances of Large Area Silicon Photomultipliers Fabricated at STMicroelectronics [J].
Mazzillo, Massimo ;
Condorelli, Giovanni ;
Sanfilippo, Delfo ;
Valvo, Giuseppina ;
Carbone, Beatrice ;
Piana, Angelo ;
Fallica, Giorgio ;
Ronzhin, Anatoly ;
Demarteau, Marcel ;
Los, Sergey ;
Ramberg, Erik .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) :2273-2279