A comparison of plusoptiX A12 measurements with cycloplegic refraction

被引:22
作者
Fogel-Levin, Miri [1 ,2 ]
Doron, Ravid [1 ,2 ]
Wygnanski-Jaffe, Tamara [1 ,2 ]
Ancri, Ofer [1 ,2 ]
Ben Zion, Itay [1 ,2 ]
机构
[1] Tel Aviv Univ, Goldschleger Eye Inst, Sheba Med Ctr, Tel Aviv, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv, Israel
来源
JOURNAL OF AAPOS | 2016年 / 20卷 / 04期
关键词
RISK-FACTORS; STATISTICAL-METHODS; VISION SCREENER; CHILDREN; AMBLYOPIA; PHOTOSCREENER; RETINOSCOPY; GUIDELINES; AGREEMENT; ACCURACY;
D O I
10.1016/j.jaapos.2016.04.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To test the accuracy and reliability of the plusoptiX A12 in detecting amblyogenic risk factors. METHODS We prospectively collected data on children undergoing screening with the plusoptiX A12, cycloplegic refraction, and complete ophthalmic examination. American Association for Pediatric Ophthalmology and Strabismus (AAPOS) 2013 guidelines for the detection of amblyogenic risk factors were used for plusoptiX A12 screening and comparison of the results of both examination modes. RESULTS Data on 402 eyes of 201 children (mean age, 7.63 +/- 3.41 years) was collected. Mean (with standard deviation) cycloplegic refraction results were as follows: sphere, 0.88 +/- 1.5 D; cylinder, -0.61 +/- 0.74 D; axis, 71.17 +/- 71.04; and spherical equivalent, 0.68 +/- 2.63. The plusoptiX A12 measurements were as follows: sphere, 0.58 +/- 1.4 D; cylinder, -0.66 +/- 0.77 D; axis, 77.3 +/- 68.9; and spherical equivalent, 0.25 +/- 1.3. We found a strong correlation (Pearson) for sphere (r = 0.91), cylinder (r = 0.81), and axis (r = 0.7). The mean difference of the myopic spherical component between the plusoptiX and cycloplegic refraction was -0.048 +/- 0.55 (95% LoA, +1.04 to -1.14 D); for the hyperopic spherical component, 0.37 +/- 0.93 (LoA, +2.20 to -1.45 D); and for the cylindrical component, 0.05 +/- 0.32 (LoA, +0.68 to -0.57D). The sensitivity, specificity, positive and negative predictive values for myopia were, respectively, 86%, 93%, 82%, and 94%; for astigmatism, 85%, 98%, 88% and 98%; and for hyperopia, 40%, 100%, 100%, and 98%. CONCLUSIONS The plusoptiX A12 accuracy is high in all subgroups but better in the myopic, astigmatic, and anisometropic subgroups. Reliability was lower in the hyperopic eyes, possibly resulting in underestimation of hyperopic refractive error.
引用
收藏
页码:310 / 314
页数:5
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   The accuracy of the plusoptiX A08 photoscreener in detecting risk factors for amblyopia in central Iowa [J].
Bloomberg, Justin D. ;
Suh, Donny W. .
JOURNAL OF AAPOS, 2013, 17 (03) :301-304
[3]   Vision screening in children by Plusoptix Vision Screener compared with gold-standard orthoptic assessment [J].
Dahlmann-Noor, A. H. ;
Vrotsou, K. ;
Kostakis, V. ;
Brown, J. ;
Heath, J. ;
Iron, A. ;
McGill, S. ;
Vivian, A. J. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (03) :342-345
[4]   Comparison of photorefraction, autorefractometry and retinoscopy in children [J].
Demirci, Goktug ;
Arslan, Banu ;
Ozsutcu, Mustafa ;
Eliacik, Mustafa ;
Gulkilik, Gokhan .
INTERNATIONAL OPHTHALMOLOGY, 2014, 34 (04) :739-746
[5]   Guidelines for automated preschool vision screening: A 10-year, evidence-based update [J].
Donahue, Sean P. ;
Arthur, Brian ;
Neely, Daniel E. ;
Arnold, Robert W. ;
Silbert, David ;
Ruben, James B. .
JOURNAL OF AAPOS, 2013, 17 (01) :4-8
[6]   Preschool vision screening: What should we be detecting and how should we report it? Uniforn guidelines for reporting results of preschool vision screening studies [J].
Donahue, SP ;
Arnold, RW ;
Ruben, JB .
JOURNAL OF AAPOS, 2003, 7 (05) :314-316
[7]   Early screening for amblyogenic risk factors lowers the prevalence and severity of amblyopia [J].
Eibschitz-Tsimhoni, M ;
Friedman, T ;
Naor, J ;
Eibschitz, N ;
Friedman, Z .
JOURNAL OF AAPOS, 2000, 4 (04) :194-199
[8]   Visual screening of Swedish children:: An ophthalmological evaluation [J].
Kvarnström, G ;
Jakobsson, P ;
Lennerstrand, G .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (03) :240-244
[9]   Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in children [J].
Matta, Noelle S. ;
Singman, Eric L. ;
Silbert, David I. .
JOURNAL OF AAPOS, 2008, 12 (05) :490-492
[10]   Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology [J].
McAlinden, Colm ;
Khadka, Jyoti ;
Pesudovs, Konrad .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (04) :330-338