Development of an acoustic leak monitoring system

被引:4
作者
Morozov, S. A.
Kovtun, S. N.
Budarin, A. A.
Dvornikov, P. A.
Kudryaev, A. A.
Kondratovich, F. V.
Shutov, P. S.
Shvetsov, D. M.
Konoplev, N. P.
机构
[1] State Science Center, Russian Federation
关键词
Nuclear Power Plant; Acoustic Sensor; Acoustic System; VVER Reactor; Primary Transducer;
D O I
10.1007/s10512-007-0149-1
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The purpose, structure, and basic characteristics of an acoustic system for monitoring coolant leaks in the first loop of a VVER reactor are presented. The principle of operation of the diagnostics algorithm is described. The system has been checked on a special stand. The system satisfies all sensitivity and temporal requirements. In 2005, SAKT was put into experimental operation in the No. 3 unit of the Kalinin nuclear power plant.