Direct-determination of high-concentration sulfate by serial differential spectrophotometry with multiple optical pathlengths

被引:21
作者
Cheng, Wen [1 ]
Zhang, Xuefei [2 ]
Duan, Ning [1 ,2 ]
Jiang, Linhua [1 ,2 ]
Xu, Yanli [1 ]
Chen, Ying [1 ]
Liu, Yong [2 ]
Fan, Peng [1 ]
机构
[1] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resources Reuse, Shanghai 200092, Peoples R China
[2] Anhui Univ Sci & Technol, Sch Mat Sci & Engn, Huainan 232001, Anhui, Peoples R China
关键词
High concentration sulfate; Adaptation method; Sensitivity; Spectrophotometry; Environmental monitoring; HEAVY-METAL; UV; SPECTROSCOPY; QUANTIFICATION; SEAWATER; REMOVAL;
D O I
10.1016/j.scitotenv.2021.152121
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Direct-determination is a fast and free of contamination method for analysis of substances in water samples. However, direct-determination of SO4- with high concentration in environmental systems is still challenging due to deviation from Beer-Lambert law is generally observed when a substance with high concentration is directly determined, resulting in poor accuracy, sensitivity, and narrow linear range. In this study, a simple and rapid method for the directdetermination of SO4- with high concentration was proposed. Serial high-absorbance differential spectrophotometry was applied to incrementally widen the determination range under different optical pathlengths. In this process, the effects of optical pathlength and reference concentration on sensitivity were further investigated. The results showed that SO4- could be accurately quantified within a concentration range of 0-4.10 g/L, and the determination range by this method was 10-fold and 19.5-fold wider than those by conventional differential spectrophotometry and conventional spectrophotometry, respectively. And the applicable ranges of sensitivity were obtained at various optical pathlengths by adjusting the reference solution concentration. This approach exhibited several advantages over conventional methods, including high accuracy, excellent precision, low cost, less time consumption, and easy operation. This method is promising and can provide accurate and reliable data support for environmental monitoring and pollution control.
引用
收藏
页数:10
相关论文
共 44 条
[41]  
Yang CH, 2012, J CHEM SOC PAKISTAN, V34, P72
[42]   Colorimetric detection of neomycin sulfate in tilapia based on plasmonic core-shell Au@PVP nanoparticles [J].
Zhang, Qin ;
He, Luying ;
Rani, Karuppasamy Kohila ;
Wu, Deyin ;
Han, Jiaojiao ;
Chen, Yanhong ;
Su, Wenjin .
FOOD CHEMISTRY, 2021, 356
[43]   "Guide Star" Assisted Noninvasive Photoacoustic Measurement of Glucose [J].
Zhang, Ruochong ;
Gao, Fei ;
Feng, Xiaohua ;
Jin, Haoran ;
Zhang, Shaohua ;
Liu, Siyu ;
Luo, Yunqi ;
Xing, Bengang ;
Zheng, Yuanjin .
ACS SENSORS, 2018, 3 (12) :2550-2557
[44]   A spectrophotometric method for simultaneous determination of trace ions of copper, cobalt, and nickel in the zinc sulfate solution by ultraviolet-visible spectrometry [J].
Zhou, Fengbo ;
Li, Changgeng ;
Yang, Chunhua ;
Zhu, Hongqiu ;
Li, Yonggang .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 223