Liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry based method for target analysis and suspect screening of non-ionic surfactants in textiles

被引:17
作者
Luo, Xin [1 ]
Zhang, Li [2 ]
Niu, Zengyuan [1 ]
Ye, Xiwen [1 ]
Tang, Zhixu [1 ]
Xia, Shuwei [2 ]
机构
[1] Inspect & Quarantine Tech Ctr, Shandong Entry Exit Inspect & Quarantine Bur, Qingdao 266002, Peoples R China
[2] Ocean Univ China, Coll Chem & Chem Engn, Qingdao 266100, Peoples R China
基金
国家重点研发计划;
关键词
Alkylphenol polyethoxylates (APEO5); Alcohol polyethoxylates (AEOs); Orbitrap; High resolution mass spectrometry; Liquid chromatography; Textiles; ALKYLPHENOL ETHOXYLATES; WASTE-WATER; ALCOHOL ETHOXYLATES; ION-TRAP; NONYLPHENOL POLYETHOXYLATES; METABOLITES; OCTYLPHENOL; SEDIMENTS; PRODUCTS; CARBOXYLATES;
D O I
10.1016/j.chroma.2017.11.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we describe a high-throughput and sensitive method for textiles analysis, using liquid chromatography coupled to quadrupole-Orbitrap high resolution mass spectrometry (LC-Q-Orbitrap HRMS), for the simultaneously quantitative analysis of 40 target alkylphenol polyethoxylates (APED) oligomers with reference standards and screening of 160 alcohol polyethoxylates (AEO) oligomers without standards in textiles. The APEOs contain nonylphenol ethoxylates (NPEOs) and octylphenol ethoxylates (OPEOs) with an EO number of ethylene oxide of 1-20, while AEOs focus on C-11 EOs-C18EOs with an EO number of 1-20. After ultrasonic extraction in methanol, the extract was directly separated using a core-shell CORTECS C-18(+) column and analyzed by Full MS/dd-MS2 (data dependent acquisition) scan in ESI positive mode. Two best sensitivity experimental conditions for APEOs with short EO chains (AP(EO)(1-2)) and long EO chains (AP(EO)(3-20)) were investigated, respectively. Most APED oligomers had wide concentration ranges and the correlation coefficients (R-2) were higher than 0.999. The limit of quantitation (LOQ) values for NP(EO)(3-20) oligomers ranges from 16.00 to 52.80 mu g/kg and for OP(EO)(3-20) oligomers is from 2.40 to 8.00 mu g/kg. LOQ for NP(EO)(1) and NP(EO)(2), OP(EO)(1) and OP(EO)(2) was 2.40 mg/kg and 0.24 mg/kg, 1.20 mg/kg and 0.16 mg/kg, respectively. The average recovery for each APED oligomer in cotton and polyester matrix was between 78% and 110% at three spiked levels and the relative standard deviation (RSD%) was below 10%. As to AEOs suspects, a HRMS compound database containing 160 AEO oligomers was built and several parameters such as exact m/z, isotopic patterns, predicted product ions and predicted retention time were used for screening and confirmation. The established method was successfully applied for analysis of 40 commercial textile samples. Compared with OPEOs, NPEOs, especially NP(EO)(3-15) oligomers, were widely detected in samples and the total concentration ranged from 1.56 to 1376.31 mg/kg. AEOs were also found in most samples, among which C12-14, C-16 and C-18 compounds appeared more frequently and the EO\ chains mainly ranged from 3 to 15. (C) 2017 Published by Elsevier B.V.
引用
收藏
页码:80 / 89
页数:10
相关论文
共 47 条
[1]   Advances in liquid chromatography-high-resolution mass spectrometry for quantitative and qualitative environmental analysis [J].
Acena, Jaume ;
Stampachiacchiere, Serena ;
Perez, Sandra ;
Barcelo, Damia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (21) :6289-6299
[2]  
[Anonymous], 2016, RESULTS PROFICIENCY
[3]  
[Anonymous], 2017, 100 OEK
[4]  
[Anonymous], 2009, Human Environmental Risk Assessment on ingredients of European household cleaning products: Alcohol Ethoxylates
[5]  
ASTM International Standard, D774211 ASTM INT
[6]   Optimization and Simultaneous Determination of Alkyl Phenol Ethoxylates and Brominated Flame Retardants in Water after SPE and Heptafluorobutyric Anhydride Derivatization followed by GC/MS [J].
Chokwe, Tlou B. ;
Okonkwo, Jonathan O. ;
Sibali, Linda L. ;
Ncube, Esper J. .
CHROMATOGRAPHIA, 2012, 75 (19-20) :1165-1176
[7]   Routine analysis of alcohol and nonylphenol polyethoxylates in wastewater and sludge using liquid chromatography-electro spray mass spectrometry [J].
Cohen, A ;
Klint, K ;
Bowadt, S ;
Persson, P ;
Jönsson, JÅ .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :103-110
[8]   Analysis of emerging contaminants in water and solid samples using high resolution mass spectrometry with a Q Exactive orbital ion trap and estrogenic activity with YES-assay [J].
Comtois-Marotte, Simon ;
Chappuis, Thomas ;
Sung Vo Duy ;
Gilbert, Nicolas ;
Lajeunesse, Andre ;
Taktek, Salma ;
Desrosiers, Melanie ;
Veilleux, Eloise ;
Sauve, Sebastien .
CHEMOSPHERE, 2017, 166 :400-411
[9]   Rapid liquid chromatography-tandem mass spectrometry-based method for the analysis of alcohol ethoxylates and alkylphenol ethoxylates in environmental samples [J].
DeArmond, Patrick D. ;
DiGoregorio, Amanda L. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1305 :154-163
[10]   Determination of lipophilic marine toxins in mussels. Quantification and confirmation criteria using high resolution mass spectrometry [J].
Domenech, Albert ;
Cortes-Francisco, Nuria ;
Palacios, Oscar ;
Franco, Jose M. ;
Riobo, Pilar ;
Llerena, Jose J. ;
Vichi, Stefania ;
Caixach, Josep .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1328 :16-25