Bronchoscopic suctioning may cause lung collapse: a lung model and clinical evaluation

被引:26
作者
Lindgren, S. [1 ]
Odenstedt, H. [1 ]
Erlandsson, K. [1 ]
Grivans, C. [1 ]
Lundin, S. [1 ]
Stenqvist, O. [1 ]
机构
[1] Sahlgrens Univ Hosp, Dept Anaesthesia & Intens Care, SE-41345 Gothenburg, Sweden
关键词
ALI; fiberbronchoscopy; electric impedance tomography; FRC; mechanical ventilation; suctioning;
D O I
10.1111/j.1399-6576.2007.01499.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To assess lung volume changes during and after bronchoscopic suctioning during volume or pressure-controlled ventilation (VCV or PCV). Design: Bench test and patient study. Participants: Ventilator-treated acute lung injury (ALI) patients. Setting: University research laboratory and general adult intensive care unit of a university hospital. Interventions: Bronchoscopic suctioning with a 12 or 16 Fr bronchoscope during VCV or PCV. Measurements: Suction flow at vacuum levels of -20 to -80 kPa was measured with a Timeter (TM) instrument. In a water-filled lung model, airway pressure, functional residual capacity (FRC) and tidal volume were measured during bronchoscopic suctioning. In 13 ICU patients, a 16 Fr bronchoscope was inserted into the left or the right main bronchus during VCV or PCV and suctioning was performed. Ventilation was monitored with electric impedance tomography (EIT) and FRC with a modified N-2 washout/in technique. Airway pressure was measured via a pressure line in the endotracheal tube. Suction flow through the 16 Fr bronchoscope was 5 l/min at a vacuum level of -20 kPa and 17 l/min at -80 kPa. Derecruitment was pronounced during suctioning and FRC decreased with -479 +/- 472 ml, P < 0.001. Conclusions: Suction flow through the bronchoscope at the vacuum levels commonly used is well above minute ventilation in most ALI patients. The ventilator was unable to deliver enough volume in either VCV or PCV to maintain FRC and tracheal pressure decreased below atmospheric pressure.
引用
收藏
页码:209 / 218
页数:10
相关论文
共 27 条
[1]  
*AARC, 1993, RESP CARE
[2]   Monitoring changes in lung air and liquid volumes with electrical impedance tomography [J].
Adler, A ;
Amyot, R ;
Guardo, R ;
Bates, JHT ;
Berthiaume, Y .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1762-1767
[3]  
Arai T, 1989, J Anesth, V3, P183, DOI 10.1007/s0054090030183
[4]   The American-European Consensus Conference on ARDS, Part 2 - Ventilatory, pharmacologic, supportive therapy, study design strategies and issues related to recovery and remodeling [J].
Artigas, A ;
Bernard, GR ;
Carlet, J ;
Dreyfuss, D ;
Gattinoni, L ;
Hudson, L ;
Lamy, M ;
Marini, JJ ;
Matthay, MA ;
Pinsky, MR ;
Spragg, R ;
Suter, PM ;
Marini, JJ ;
Dreyfuss, D ;
Blanch, L ;
Burchardi, H ;
Hedenstierna, G ;
Lemaire, F ;
Roussos, C ;
Mancebo, J ;
Morris, A ;
Pesenti, A ;
Rossi, A ;
Bernard, GR ;
Lamy, M ;
Van Asbeck, BS ;
Brigham, KL ;
Dhainaut, JF ;
Fowler, AA ;
Hyers, TM ;
Morel, D ;
Rodriguez-Roisin, R ;
Schaller, MD ;
Pinsky, MR ;
Suter, PM ;
Hemmer, M ;
Torres, A ;
Villar, J ;
Vincent, JL ;
Matthay, MA ;
Gattinoni, L ;
Leeper, K ;
Meyrick, B ;
Oppenheimer, L ;
Reid, L ;
Artigas, A ;
Carlet, J ;
Hudson, DL ;
Murray, JE ;
Spragg, R .
INTENSIVE CARE MEDICINE, 1998, 24 (04) :378-398
[5]   Endotracheal tube intraluminal diameter narrowing after mechanical ventilation:: use of acoustic reflectometry [J].
Boqué, MC ;
Gualis, B ;
Sandiumenge, A ;
Rello, J .
INTENSIVE CARE MEDICINE, 2004, 30 (12) :2204-2209
[6]   Lung recruitment manoeuvres are effective in regaining lung volume and oxygenation after open endotracheal suctioning in acute respiratory distress syndrome [J].
Dyhr, T ;
Bonde, J ;
Larsson, A .
CRITICAL CARE, 2003, 7 (01) :55-62
[7]   Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery [J].
Erlandsson, K. ;
Odenstedt, H. ;
Lundin, S. ;
Stenqvist, O. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (07) :833-839
[8]   Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure [J].
Frerichs, I ;
Hahn, G ;
Hellige, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :764-773
[9]   Electrical impedance tomography in monitoring experimental lung injury [J].
Frerichs, I ;
Hahn, G ;
Schroder, T ;
Hellige, G .
INTENSIVE CARE MEDICINE, 1998, 24 (08) :829-836
[10]   Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? [J].
Frerichs, I ;
Dargaville, PA ;
Dudykevych, T ;
Rimensberger, PC .
INTENSIVE CARE MEDICINE, 2003, 29 (12) :2312-2316