Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

被引:45
作者
Mattera, Lucia [1 ,2 ,3 ]
Bhuckory, Shashi [4 ]
Wegner, K. David [4 ,7 ]
Qiu, Xue [4 ]
Agnese, Fabio [1 ,5 ]
Lincheneau, Christophe [1 ,2 ,3 ]
Senden, Tim [1 ,2 ,3 ]
Djurado, David [1 ,2 ,3 ]
Charbonniere, Loic J. [6 ]
Hildebrandt, Niko [4 ]
Reiss, Peter [1 ,2 ,3 ]
机构
[1] Univ Grenoble Alpes, INAC SyMMES, F-38054 Grenoble 9, France
[2] CEA Grenoble, INAC SyMMES, Lab STEP, 17 Rue Martyrs, F-38054 Grenoble 9, France
[3] CNRS, SPrAM, F-38054 Grenoble 9, France
[4] Univ Paris Saclay, Univ Paris Sud, CNRS, NanoBioPhoton Nanofret Com,Inst Elect Fondamental, F-91405 Orsay, France
[5] CEA Grenoble, INAC MEM, LEMMA, 17 Rue Martyrs, F-38054 Grenoble 9, France
[6] UdS, CNRS, ECPM, IPHC,UMR 7178,LIMAA, 25 Rue Becquerel, F-67087 Strasbourg 2, France
[7] CEA Grenoble, INAC SyMMES, 17 Rue Martyrs, F-38054 Grenoble 9, France
关键词
RESONANCE ENERGY-TRANSFER; INP/ZNS NANOCRYSTALS; FLUORESCENCE; LANTHANIDES; DIAGNOSTICS; ACCEPTORS; DONORS;
D O I
10.1039/c6nr03261c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter <13 nm, PL quantum yield up to 66% at 705 nm, and colloidal stability of several months in various buffers. They were applied as FRET acceptors in homogeneous, time-gated immunoassays using Tb-antibodies as FRET donors, both coupled by an immunological sandwich complex between the two antibodies and a PSA (prostate specific antigen) biomarker. The advantages of the compact surface coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL(-1) obtained in 50 mu L serum samples are below the clinical cutoff level of PSA (4 ng mL(-1)) and demonstrate their direct applicability in clinical diagnostics.
引用
收藏
页码:11275 / 11283
页数:9
相关论文
共 47 条
[11]   Quantum-dot-based homogeneous time-resolved fluoroimmunoassay of alpha-fetoprotein [J].
Chen, Mei-Jun ;
Wu, Ying-Song ;
Lin, Guan-Feng ;
Hou, Jing-Yuan ;
Li, Ming ;
Liu, Tian-Cai .
ANALYTICA CHIMICA ACTA, 2012, 741 :100-105
[12]   A Novel Homogeneous Time-Resolved Fluoroimmunoassay for Carcinoembryonic Antigen Based on Water-Soluble Quantum Dots [J].
Chen, Zhen-Hua ;
Wu, Ying-Song ;
Chen, Mei-Jun ;
Hou, Jing-Yuan ;
Ren, Zhi-Qi ;
Sun, Da ;
Liu, Tian-Cai .
JOURNAL OF FLUORESCENCE, 2013, 23 (04) :649-657
[13]   Complex Logic Functions Implemented with Quantum Dot Bionanophotonic Circuits [J].
Claussen, Jonathan C. ;
Hildebrandt, Niko ;
Susumu, Kimihiro ;
Ancona, Mario G. ;
Medintz, Igor L. .
ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (06) :3771-3778
[14]   Applications of quantum dots as probes in immunosensing of small-sized analytes [J].
Esteve-Turrillas, Francesc A. ;
Abad-Fuentes, Antonio .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :12-29
[15]   A disposable immunosensor device for point-of-care test of tumor marker based on copper-mediated amplification [J].
Ge, Shenguang ;
Ge, Lei ;
Yan, Mei ;
Song, Xianrang ;
Yu, Jinghua ;
Liu, Shanshan .
BIOSENSORS & BIOELECTRONICS, 2013, 43 :425-431
[16]   Lanthanides and Quantum Dots as Forster Resonance Energy Transfer Agents for Diagnostics and Cellular Imaging [J].
Geissler, Daniel ;
Linden, Stina ;
Liermann, Konstanze ;
Wegner, K. David ;
Charbonniere, Loic J. ;
Hildebrandt, Niko .
INORGANIC CHEMISTRY, 2014, 53 (04) :1824-1838
[17]   Six-Color Time-Resolved Forster Resonance Energy Transfer for Ultrasensitive Multiplexed Biosensing [J].
Geissler, Daniel ;
Stufler, Stefan ;
Loehmannsroeben, Hans-Gerd ;
Hildebrandt, Niko .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (03) :1102-1109
[18]   Quantum Dot Biosensors for Ultrasensitive Multiplexed Diagnostics [J].
Geissler, Daniel ;
Charbonniere, Loic J. ;
Ziessel, Raymond F. ;
Butlin, Nathaniel G. ;
Loehmannsroeben, Hans-Gerd ;
Hildebrandt, Niko .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (08) :1396-1401
[19]   Prostate Specific Antigen Best Practice Statement: 2009 Update [J].
Greene, Kirsten L. ;
Albertsen, Peter C. ;
Babaian, Richard J. ;
Carter, H. Ballentine ;
Gann, Peter H. ;
Han, Misop ;
Kuban, Deborah Ann ;
Sartor, A. Oliver ;
Stanford, Janet L. ;
Zietman, Anthony ;
Carroll, Peter .
JOURNAL OF UROLOGY, 2013, 189 (01) :S2-S11
[20]   Luminescent energy transfer between cadmium telluride nanoparticle and lanthanide(III) chelate in competitive bioaffinity assays of biotin and estradiol [J].
Harma, Harri ;
Soukka, Tero ;
Shavel, Alexey ;
Gaponik, Nikolai ;
Weller, Horst .
ANALYTICA CHIMICA ACTA, 2007, 604 (02) :177-183