Extracting source parameters from beam monitors on a chopper spectrometer

被引:9
|
作者
Abernathy, D. L. [1 ]
Niedziela, J. L. [2 ]
Stone, M. B. [1 ]
机构
[1] Oak Ridge Natl Lab, Quantum Condensed Matter Div, Oak Ridge, TN 37831 USA
[2] Oak Ridge Natl Lab, Instrument & Source Div, Oak Ridge, TN 37831 USA
来源
QENS/WINS 2014 - 11TH INTERNATIONAL CONFERENCE ON QUASIELASTIC NEUTRON SCATTERING AND 6TH INTERNATIONAL WORKSHOP ON INELASTIC NEUTRON SPECTROMETERS | 2015年 / 83卷
关键词
D O I
10.1051/epjconf/20158303001
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] A Simple Raman Spectrometer with Laser Beam Source.
    Meier, W.
    Schrader, B.
    Pisarcik, M.
    Messtechnik, 1972, 80 (05): : 119 - 126
  • [22] Electrodes for Beam Position Monitors for Fourth Generation Synchrotron Radiation Source
    D. A. Liakin
    S. V. Barabin
    A. Yu. Orlov
    M. S. Saratovskikh
    T. V. Kulevoy
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2019, 13 : 511 - 514
  • [23] Sensitivity and offset calibration for the beam position monitors at the advanced photon source
    Chung, Y
    Barr, D
    Decker, G
    Evans, K
    Kahana, E
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 2452 - 2454
  • [24] Electrodes for Beam Position Monitors for Fourth Generation Synchrotron Radiation Source
    Liakin, D. A.
    Barabin, S. V.
    Orlov, A. Yu.
    Saratovskikh, M. S.
    Kulevoy, T. V.
    JOURNAL OF SURFACE INVESTIGATION, 2019, 13 (03): : 511 - 514
  • [25] Extracting OSNR from low-resolution optical channel monitors
    Li, Mei
    Pendock, Graeme J.
    Evans, Rob J.
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2007, 19 (5-8) : 303 - 305
  • [26] CHOPPER SPECTROMETER FOR INELASTIC NEUTRON-SCATTERING AT THE ZING-P' PULSED NEUTRON SOURCE AT ARGONNE
    PELIZZARI, CA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (03): : 365 - 365
  • [27] The cold neutron chopper spectrometer at the Spallation Neutron Source-A review of the first 8 years of operation
    Ehlers, G.
    Podlesnyak, A. A.
    Kolesnikov, A. I.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (09):
  • [28] Development of a fast traveling-wave beam chopper for the National Spallation Neutron Source
    Kurennoy, SS
    Jason, AJ
    Krawczyk, FL
    Power, J
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 3731 - 3733
  • [29] Development of a fast traveling-wave beam chopper for the National Spallation Neutron Source
    Los Alamos Natl Lab, Los Alamos, United States
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 3 : 3731 - 3733
  • [30] MODULATED MOLECULAR-BEAM SOURCE-MASS SPECTROMETER
    VASILE, MJ
    STEVIE, FA
    FALCONER, WE
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1975, 17 (02): : 195 - 207