PSpice modelling diffraction effects in pulse echo ultrasonic system
被引:3
作者:
Aouzale, Noureddine
论文数: 0引用数: 0
h-index: 0
机构:
Fac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, MoroccoFac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, Morocco
Aouzale, Noureddine
[1
]
Chitnalah, Ahmed
论文数: 0引用数: 0
h-index: 0
机构:
Fac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, MoroccoFac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, Morocco
Chitnalah, Ahmed
[1
]
Jakjoud, Hicharn
论文数: 0引用数: 0
h-index: 0
机构:
Fac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, MoroccoFac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, Morocco
Jakjoud, Hicharn
[1
]
Kourtiche, Djilah
论文数: 0引用数: 0
h-index: 0
机构:
Univ Henri Ponicare, Lab Instrumentat Elect Nancy, Vandoeuvre Les Nancy, FranceFac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, Morocco
Kourtiche, Djilah
[2
]
机构:
[1] Fac Sci & Technol, Elect Syst & Telecommun Lab, BP 549, Marrakech, Morocco
[2] Univ Henri Ponicare, Lab Instrumentat Elect Nancy, Vandoeuvre Les Nancy, France
来源:
2007 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-4
|
2007年
关键词:
D O I:
10.1109/ICECS.2007.4510929
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
The ultrasonic wave propagation is affected by absorption and diffraction. The transmission line is used to simulate the propagation media in PSpice model. To take into account diffraction effects we used the model proposed by J. Johansson [11]. A set of Gaussian beam is used to simulate the radiated field allowing us to deduce the exact diffraction loss. The diffraction loss is incorporated into the transmission line model using the attenuation parameter G. Measurements have been performed using a pulse echo system transmitting in water. The measurements show good agreement with the simulation results.