Ultra-compact micro-photoacoustic tomography for brain imaging in vivo

被引:2
作者
Deng, Lijun [1 ,2 ]
He, Xingdao [3 ]
Zhang, Jian [4 ]
Liu, Guodong [2 ]
Han, Song [5 ]
Lou, Yimin [6 ]
Zeng, Lvming [1 ,2 ]
Ji, Xuanrong [1 ]
机构
[1] Guangdong Univ Technol, State Key Lab Precis Elect Mfg Technol & Equipmen, Guangzhou 510663, Peoples R China
[2] Jiangxi Sci & Technol Normal Univ, Key Lab Opt Elect & Commun, Nanchang 3300382, Jiangxi, Peoples R China
[3] Nanchang Hangkong Univ, Natl Engn Lab Destruct Testing & Optoelect Sensin, Nanchang 330063, Jiangxi, Peoples R China
[4] Guangzhou Med Univ, Sch Basic Med Sci, Guangzhou 511436, Peoples R China
[5] Doppler Elect Technol Inc Co, Guangzhou 510530, Peoples R China
[6] Zhejiang Sci Tech Univ, Key Lab Opt Field Manipulat Zhejiang Prov, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金;
关键词
COMPUTED-TOMOGRAPHY; MOUSE-BRAIN;
D O I
10.1063/5.0076948
中图分类号
O59 [应用物理学];
学科分类号
摘要
In vivo wide-field brain microscopy has remained a non-trivial challenge in life science research, which would provide indispensable preclinical insight into the whole-brain metabolism and hemodynamic. Here, we developed an ultra-compact micro-photoacoustic tomography (mu PAT) system for fast brain imaging equipped with a 10 MHz 256-element full-ring ultrasound transducer array and 100 MS/s/ch multi-channel parallel data acquisition. The system design and calibration are presented in detail, along with the 62 mu m in-plane resolution comparable to the level of acoustic-resolution photoacoustic microscopy. The mu PAT system provided the ability to noninvasively use high-resolution mapping of the microvascular network of the full-view brain at different depths, cerebral ischemia, and intracerebral foreign-body. Ultra-compact mu PAT holds great potential to take the technology out of the lab for preclinical imaging and clinical translation.
引用
收藏
页数:6
相关论文
共 30 条
[1]   Fluorine microimaging and quantification using nuclear reaction analysis: A tool for validating tissue distribution of positron emission tomography tracers [J].
Deves, G. ;
Roudeau, S. ;
Carmona, A. ;
Lavielle, S. ;
Gionnet, K. ;
Deleris, G. ;
Ortega, R. .
APPLIED PHYSICS LETTERS, 2009, 95 (02)
[2]   Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging [J].
Fox, Michael D. ;
Raichle, Marcus E. .
NATURE REVIEWS NEUROSCIENCE, 2007, 8 (09) :700-711
[3]   Curved array photoacoustic tomographic system for small animal imaging [J].
Gamelin, John ;
Aguirre, Andres ;
Maurudis, Anastasios ;
Huang, Fei ;
Castillo, Diego ;
Wang, Lihong V. ;
Zhu, Quing .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
[4]   Effective x-ray attenuation coefficient measurements from two full field digital mammography systems for data calibration applications [J].
Heine, John J. ;
Thomas, Jerry A. .
BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
[5]   Spatiotemporal Antialiasing in Photoacoustic Computed Tomography [J].
Hu, Peng ;
Li, Lei ;
Lin, Li ;
Wang, Lihong V. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (11) :3535-3547
[6]   Curved-Array-Based Multispectral Photoacoustic Imaging of Human Finger Joints [J].
Huang, Na ;
He, Ming ;
Shi, Haosheng ;
Zhao, Yuan ;
Lu, Man ;
Zou, Xianbing ;
Yao, Lei ;
Jiang, Huabei ;
Xi, Lei .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (07) :1452-1459
[7]  
Jensen J. A., 1996, Medical & Biological Engineering & Computing, V34, P351
[8]   Interpolated model-matrix optoacoustic tomography of the mouse brain [J].
Jetzfellner, Thomas ;
Rosenthal, Amir ;
Englmeier, K. -H. ;
Dima, Alexander .
APPLIED PHYSICS LETTERS, 2011, 98 (16)
[9]   Compressed Sensing-Based Super-Resolution Ultrasound Imaging for Faster Acquisition and High Quality Images [J].
Kim, Jihun ;
Wang, Qingfei ;
Zhang, Siyuan ;
Yoon, Sangpil .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (11) :3317-3326
[10]  
Laser Institute of America, 2000, Z1361 LAS I AM ANSI