High Cecal Intubation Rates With a New Computer-Assisted Colonoscope: A Feasibility Study

被引:43
作者
Groth, Stefan [1 ]
Rex, Douglas K. [2 ]
Roesch, Thomas [1 ]
Hoepffner, Nicolas [3 ]
机构
[1] Univ Hosp Hamburg Eppendorf, Dept Interdisciplinary Endoscopy, D-20246 Hamburg, Germany
[2] Indiana Univ Hosp, Dept Gastroenterol, Indianapolis, IN 46202 USA
[3] Gastroenterol Practice Bethanien Hosp, Frankfurt, Germany
关键词
RANDOMIZED CONTROLLED-TRIAL; COLORECTAL-CANCER; GASTROINTESTINAL ENDOSCOPY; CARBON-DIOXIDE; WHITE-LIGHT; NARROW-BAND; PREVENTION; SEDATION; SOCIETY; POLYPS;
D O I
10.1038/ajg.2011.52
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: The acceptability of colonoscopy as a screening test is limited by several factors including patient discomfort. A new self-propelled colonoscope, the Invendo SC20 (Invendo Medical GmbH), may be helpful in reducing sedation. It consists of a sheathed endoscope contained within an "inverted sleeve," and having an instrument channel and an electrohydraulic bendable tip; it is steered using a handheld device and propelled by a motorized drive unit. This study assessed the safety and efficacy of this new endoscope in volunteers undergoing colorectal cancer (CRC) screening. METHODS: Paid healthy volunteers aged 50-70 years and eligible for screening colonoscopy were included. Total colonoscopy using carbon dioxide insufflation or water instillation on demand was attempted, with all procedures being started without sedation. The main outcome parameters were safety and the cecal intubation rate. RESULTS: A total of 61 volunteers participated (34 men and 27 women; mean age 57.5 years). The cecum was reached in 60 volunteers (cecal intubation rate of 98.4%). The median time to reach the cecum was 15 min (range 7-53.5). Sedation was given in three individuals (4.9%). On withdrawal (median time 15 min), the material for histological evaluation was obtained from 33 polyps (mean size 4.8 mm) in 23 people by biopsy forceps or snare. No device-related complications were encountered. CONCLUSIONS: A new computer-assisted colonoscope, controlled using a handheld device, showed excellent cecal intubation rates during screening examinations, with sedation required in only similar to 5% of screenees. Further clinical and comparative studies are warranted.
引用
收藏
页码:1075 / 1080
页数:6
相关论文
共 18 条
  • [1] Narrow-Band Versus White-Light High Definition Television Endoscopic Imaging for Screening Colonoscopy: A Prospective Randomized Trial
    Adler, Andreas
    Aschenbeck, Jens
    Yenerim, Timur
    Mayr, Michael
    Aminalai, Alireza
    Drossel, Rolf
    Schroeder, Andreas
    Scheel, Matthias
    Wiedenmann, Bertram
    Roesch, Thomas
    [J]. GASTROENTEROLOGY, 2009, 136 (02) : 410 - 416
  • [2] Sedation for gastrointestinal endoscopy: New practices, new economics
    Aisenberg, J
    Brill, JV
    Ladabaum, U
    Cohen, LB
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (05) : 996 - 1000
  • [3] NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy
    Bretthauer, M
    Thiis-Evensen, E
    Huppertz-Hauss, G
    Gisselsson, L
    Grotmol, T
    Skovlund, E
    Hoff, G
    [J]. GUT, 2002, 50 (05) : 604 - 607
  • [4] Digestive endoscopy is not a major risk factor for transmitting hepatitis C virus
    Ciancio, A
    Manzini, P
    Castagno, F
    D'Antico, S
    Reynaudo, P
    Coucourde, L
    Ciccone, G
    Del Piano, M
    Ballarè, M
    Peyre, S
    Rizzi, R
    Barletti, C
    Bruno, M
    Caronna, S
    Carucci, P
    Venon, WD
    De Angelis, C
    Morgando, A
    Musso, A
    Repici, A
    Rizzetto, M
    Saracco, G
    [J]. ANNALS OF INTERNAL MEDICINE, 2005, 142 (11) : 903 - 909
  • [5] Computer-assisted colonoscopy (The NeoGuide Endoscopy System): Results of the first human clinical trial ("PACE study")
    Eickhoff, Axel
    Van Dam, Jacques
    Jakobs, Ralf
    Kudis, Valerie
    Hartmann, Dirk
    Damian, Ulrich
    Weickert, Uwe
    Schilling, Dieter
    Riemann, Juergen F.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (02) : 261 - 266
  • [6] Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy
    Eliakim, R.
    Yassin, K.
    Niv, Y.
    Metzger, Y.
    Lachter, J.
    Gal, E.
    Sapoznikov, B.
    Konikoff, F.
    Leichtmann, G.
    Fireman, Z.
    Kopelman, Y.
    Adler, S. N.
    [J]. ENDOSCOPY, 2009, 41 (12) : 1026 - 1031
  • [7] Use of sedation for routine diagnostic upper gastrointestinal endoscopy:: A European Society of Gastrointestinal Endoscopy survey of National Endoscopy Society members
    Ladas, S. D.
    Aabakken, L.
    Rey, J. -F.
    Nowak, A.
    Zakaria, S.
    Adamonis, K.
    Amrani, N.
    Bergman, J. J. G. H. M.
    Valverde, J. Boix
    Boyacioglu, S.
    Cremers, I.
    Crowe, J.
    Deprez, P.
    Dite, P.
    Eisen, M.
    Eliakim, R.
    Fedorov, E. D.
    Galkova, Z.
    Gyokeres, T.
    Heuss, L. T.
    Husic-Selimovic, A.
    Khediri, F.
    Kuznetsov, K.
    Marek, T.
    Munoz-Navas, M.
    Napoleon, B.
    Niemela, S.
    Pascu, O.
    Perisic, N.
    Pulanic, R.
    Ricci, E.
    Schreiber, F.
    Svendsen, L. B.
    Sweidan, W.
    Sylvan, A.
    Teague, R.
    Tryfonos, M.
    Urbain, D.
    Weber, J.
    Zavoral, M.
    [J]. DIGESTION, 2006, 74 (02) : 69 - 77
  • [8] Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology
    Levin, Bernard
    Lieberman, David A.
    McFarland, Beth
    Andrews, Kimberly S.
    Brooks, Durado
    Bond, John
    Dash, Chiranjeev
    Giardiello, Francis M.
    Glick, Seth
    Johnson, David
    Johnson, C. Daniel
    Levin, Theodore R.
    Pickhardt, Perry J.
    Rex, Douglas K.
    Smith, Robert A.
    Thorson, Alan
    Winawer, Sidney J.
    [J]. GASTROENTEROLOGY, 2008, 134 (05) : 1570 - 1595
  • [9] Recent advances in epidemiology and prevention of gastrointestinal endoscopy related infections
    Nelson, DB
    [J]. CURRENT OPINION IN INFECTIOUS DISEASES, 2005, 18 (04) : 326 - 330
  • [10] Usefulness of Warm Water and Oil Assistance in Colonoscopy by Trainees
    Park, Sung Chul
    Keum, Bora
    Kim, Eun Sun
    Jung, Eun Suk
    Lee, Sehe Dong
    Park, Sanghoon
    Seo, Yeon Seok
    Kim, Yong Sik
    Jeen, Yoon Tae
    Chun, Hoon Jai
    Um, Soon Ho
    Kim, Chang Duck
    Ryu, Ho Sang
    [J]. DIGESTIVE DISEASES AND SCIENCES, 2010, 55 (10) : 2940 - 2944