Detection of low molecular weight toxins using an optical phase method of ellipsometry

被引:33
作者
Nabok, A. [1 ]
Tsargorodskaya, A.
Mustafa, M. K.
Szekacs, I. [2 ,3 ]
Starodub, N. F. [4 ]
Szekacs, A. [2 ]
机构
[1] Sheffield Hallam Univ, Dept Engn & Math, Mat & Engn Res Inst, Sheffield S1 2NU, S Yorkshire, England
[2] Hungarian Acad Sci, Inst Plant Protect, H-1525 Budapest, Hungary
[3] Hungarian Acad Sci, Inst Expt Med, H-1083 Budapest, Hungary
[4] Natl Univ Life & Environm Sci Ukraine, UA-03041 Kiev, Ukraine
关键词
Spectroscopic ellipsometry; Total Internal Reflection Ellipsometry; Direct immunoassay; Competitive immunoassay; Kinetics of immune reaction; INTERNAL-REFLECTION ELLIPSOMETRY; SURFACE; BIOSENSOR; INTERFEROMETER; SENSITIVITIES; REGISTRATION; PRINCIPLES; MYCOTOXIN; SENSORS;
D O I
10.1016/j.snb.2010.02.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The method of total internal reflection ellipsometry (TIRE), which records simultaneously two parameters Delta and psi related to the amplitudes and phases of p- and s-components of polarised light, respectively, was exploited here for detection of mycotoxins (T-2 and zearalenone). The above mycotoxins in sub-ppb concentrations were detected using TIRE in both direct and competitive immunoassay. The study of immune reaction kinetics allowed the evaluation of adsorption/desorption rates and the association constant for zearalenone. The investigation of grain products samples revealed the presence of high concentrations of T-2 (>600 ng/ml) in mould products. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 42 条
[21]  
Nabok A V, 2003, IEE Proc Nanobiotechnol, V150, P25, DOI 10.1049/ip-nbt:20030571
[22]   The method of total internal reflection ellipsometry for thin film characterisation and sensing [J].
Nabok, Alexei ;
Tsargorodskaya, Anna .
THIN SOLID FILMS, 2008, 516 (24) :8993-9001
[23]   Specific binding of large aggregates of amphiphilic molecules to the respective antibodies [J].
Nabok, Alexei ;
Tsargorodskaya, Anna ;
Holloway, Alan ;
Starodub, Nikolay F. ;
Demchenko, Anna .
LANGMUIR, 2007, 23 (16) :8485-8490
[24]   Total internal reflection ellipsometry and SPR detection of low molecular weight environmental toxins [J].
Nabok, AV ;
Tsargorodskaya, A ;
Hassan, AK ;
Starodub, NF .
APPLIED SURFACE SCIENCE, 2005, 246 (04) :381-386
[25]   Phase detection of surface plasmon resonance using rotating analyzer method [J].
Naraoka, R ;
Kajikawa, K .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02) :952-956
[26]  
Park C.W., 2009, CBRNE T 2 MYCOTOXINS
[27]   In situ monitoring of metal surfaces exposed to milk using total internal reflection ellipsometry [J].
Poksinski, M ;
Arwin, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 94 (03) :247-252
[28]   Comparison between sensitivities of phase and intensity detection in surface plasmon resonance [J].
Ran, B. ;
Lipson, S. G. .
OPTICS EXPRESS, 2006, 14 (12) :5641-5650
[29]   Phase interrogation of an integrated optical SPR sensor [J].
Sheridan, AK ;
Harris, RD ;
Bartlett, PN ;
Wilkinson, JS .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (01) :114-121
[30]   Analysis of the response of planar polarization interferometer to molecular layer formation: fibrinogen adsorption on silicon nitride surface [J].
Shirshov, YM ;
Snopok, BA ;
Samoylov, AV ;
Kiyanovskij, AP ;
Venger, EF ;
Nabok, AV ;
Ray, AK .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (06) :381-390