Windings Monitoring of Wound Rotor Induction Machines under Fluctuating Load Conditions

被引:0
作者
Kia, Shahin Hedayati [1 ]
Henao, Humberto [1 ]
Capolino, Gerard-Andre [1 ]
机构
[1] Univ Picardie Jules Verne, Dept Elect Engn, F-80000 Amiens, France
来源
IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY | 2011年
关键词
AC motor protection; amplitude modulation; asynchronous rotating machines; envelope detection; fault diagnosis; Hilbert transforms; induction motors; monitoring; signal processing; wavelet transforms; SIGNATURE ANALYSIS; FAULT-DIAGNOSIS; BROKEN-BAR; CIRCUIT; MOTORS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper deals with a time-scale method for stator winding asymmetry fault and rotor winding asymmetry fault detections in wound rotor induction machines. An initial study of the rotor asymmetry in induction machines has been based on the energy evaluation of a known low frequency bandwidth with time-scale analysis. It has been shown that both the stator current space vector magnitude and the instantaneous magnitude of stator current are both good candidates to be used as an indicator for this typical fault detection in steady-state condition. In this paper, a new frequency bandwidth associated with the stator winding asymmetry fault in the rotor current signature has been introduced leading to a general form of load independent winding asymmetry detection in wound-rotor induction machines. Furthermore, the previous technique has been improved in order to detect any winding asymmetry in any fluctuating load condition for wound rotor induction machines. The proposed technique has been validated with experimental tests on a 90W wound rotor induction machine.
引用
收藏
页数:7
相关论文
共 25 条
  • [1] Online stator fault diagnosis in induction motors
    Arkan, M
    Perovic, DK
    Unsworth, P
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2001, 148 (06): : 537 - 547
  • [2] Advances in Diagnostic Techniques for Induction Machines
    Bellini, Alberto
    Filippetti, Fiorenzo
    Tassoni, Carta
    Capolino, Gerard-Andre
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4109 - 4126
  • [3] Mechanical load fault detection in induction motors by stator current time-frequency analysis
    Blodt, Martin
    Chabert, Marie
    Regnier, Jeremi
    Faucher, Jean
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2006, 42 (06) : 1454 - 1463
  • [4] Induction machine broken bar and stator short-circuit fault diagnostics based on three-phase stator current envelopes
    da Silva, Aderiano M.
    Povinelli, Richard J.
    Demerdash, Nabeel A. O.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (03) : 1310 - 1318
  • [5] Analysis of airgap flux, current, and vibration signals as a function of the combination of static and dynamic airgap eccentricity in 3-phase induction motors
    Dorrell, DG
    Thomson, WT
    Roach, S
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) : 24 - 34
  • [6] Douglas H, 2005, IEEE IND APPLIC SOC, P1097
  • [7] A new algorithm for transient motor current signature analysis using wavelets
    Douglas, H
    Pillay, P
    Ziarani, AK
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (05) : 1361 - 1368
  • [8] An equivalent internal circuit of the induction machine for advanced spectral analysis
    Henao, H
    Martis, C
    Capolino, GA
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (03) : 726 - 734
  • [9] A frequency-domain detection of stator winding faults in induction machines using an external flux sensor
    Henao, H
    Demian, C
    Capolino, GA
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (05) : 1272 - 1279
  • [10] Jaksch I, 2003, IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES, PROCEEDINGS, P289