Performance characteristic studies of glucose biosensors modified by (3-mercaptopropyl)trimethoxysilane sol-gel and non-conducting polyaniline

被引:13
作者
Yang, Yang-Li [1 ,2 ]
Tseng, Ta-Feng [1 ,2 ]
Yeh, Jui-Ming [3 ,4 ]
Chen, Chien-An [5 ]
Lou, Shyh-Liang [1 ,2 ]
机构
[1] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli 32023, Taiwan
[2] Chung Yuan Christian Univ, R&D Ctr Biomed Microdevice Technol, Chungli 32023, Taiwan
[3] Chung Yuan Christian Univ, Ctr Nanotechnol, Dept Chem, Chungli 32023, Taiwan
[4] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Chungli 32023, Taiwan
[5] Ind Technol Res Inst, Med Elect & Device Technol Ctr, Sect 4, Hsinchu 31040, Taiwan
关键词
glucose biosensors; (3-mercaptopropyl)trimethoxysilane; polyaniline; permselective membranes;
D O I
10.1016/j.snb.2007.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The materials (3-mercaptopropyl)trimethoxysilane (MPTMS) sol-gel and non-conducting polyaniline (PAn) were prepared for coating on two different amperometric biosensors fabricated by the immobilization of glucose oxidase (GOx) in conducting polyaniline (PA) as permselective membranes. A few performance characteristics of the MPTMS and the PAn-modified glucose sensors are comparable. In detecting 1 mM glucose, the biosensors' response times were 11 and 12 s, respectively, and results from the repeating measurements (N=10) showed that R.S.D. = 2.09 and 1.70%, respectively. The detection linearity of the two biosensors was up to 12.5 mM[ with R = 0.9989 and 0.9969. When they were used to detect 0.5 mM of ascorbic acid (AA), uric acid (UA), and acetaminophen at an anodic potential of 0.4 V, current signals were either insignificant or invisible. The PAn-coated glucose sensor exhibited superior sensitivity at 18.91 mu A/(mM cm(2)), and a maximum current density of 3.70 mA/cm(2). GOx in the MPTMS-modified biosensor presented a stronger affinity to glucose with K-m = 48.87. More importantly, the stability of this biosensor is superior to that of the PAn-modified biosensor and has lasted for almost 5 months. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:533 / 540
页数:8
相关论文
共 31 条
[21]   Comparison of two-typed (3-mercaptopropyl)trimethoxysilane-based networks on Au substrates [J].
Shen, YF ;
Wu, T ;
Zhang, YJ ;
Li, JH .
TALANTA, 2005, 65 (02) :481-488
[22]   Electrical contacting of glucose oxidase by DNA-templated polyaniline wires on surfaces [J].
Shi, LX ;
Xiao, Y ;
Willner, I .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (10) :1057-1060
[23]   Amperometric glucose biosensor based on adsorption of glucose oxidase at platinum nanoparticle-modified carbon nanotube electrode [J].
Tang, H ;
Chen, JH ;
Yao, SZ ;
Nie, LH ;
Deng, GH ;
Kuang, YF .
ANALYTICAL BIOCHEMISTRY, 2004, 331 (01) :89-97
[24]   DESIGN, CONSTRUCTION, AND APPLICATIONS OF A GALACTOSE SELECTIVE ELECTRODE [J].
TAYLOR, PJ ;
KMETEC, E ;
JOHNSON, JM .
ANALYTICAL CHEMISTRY, 1977, 49 (06) :789-794
[25]   Fructose biosensor based on D-fructose dehydrogenase immobilised on a ferrocene-embedded cellulose acetate membrane [J].
Tkác, J ;
Vostiar, I ;
Sturdík, E ;
Gemeiner, P ;
Mastihuba, V ;
Annus, J .
ANALYTICA CHIMICA ACTA, 2001, 439 (01) :39-46
[26]   Non-invasive glucose monitoring: Assessment of technologies and devices according to quantitative criteria [J].
Tura, Andrea ;
Maran, Alberto ;
Pacini, Giovanni .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2007, 77 (01) :16-40
[27]   Sol-gel-derived amperometric biosensor for hydrogen peroxide based on methylene green incorporated in Nafion film [J].
Wang, BQ ;
Dong, SJ .
TALANTA, 2000, 51 (03) :565-572
[28]   Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol-gel film [J].
Wang, QL ;
Lu, GX ;
Yang, BJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (01) :50-57
[29]   Set of luminescence decay time based chemical sensors for clinical applications [J].
Wolfbeis, OS ;
Klimant, I ;
Werner, T ;
Huber, C ;
Kosch, U ;
Krause, C ;
Neurauter, G ;
Dürkop, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) :17-24
[30]   Non-invasive glucose sensing with near-infrared spectroscopy enhanced by optical measurement conditions reproduction technique [J].
Xu, KX ;
Qiu, QJ ;
Jiang, JY ;
Yang, XY .
OPTICS AND LASERS IN ENGINEERING, 2005, 43 (10) :1096-1106