Performance characteristic studies of glucose biosensors modified by (3-mercaptopropyl)trimethoxysilane sol-gel and non-conducting polyaniline

被引:13
作者
Yang, Yang-Li [1 ,2 ]
Tseng, Ta-Feng [1 ,2 ]
Yeh, Jui-Ming [3 ,4 ]
Chen, Chien-An [5 ]
Lou, Shyh-Liang [1 ,2 ]
机构
[1] Chung Yuan Christian Univ, Dept Biomed Engn, Chungli 32023, Taiwan
[2] Chung Yuan Christian Univ, R&D Ctr Biomed Microdevice Technol, Chungli 32023, Taiwan
[3] Chung Yuan Christian Univ, Ctr Nanotechnol, Dept Chem, Chungli 32023, Taiwan
[4] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Chungli 32023, Taiwan
[5] Ind Technol Res Inst, Med Elect & Device Technol Ctr, Sect 4, Hsinchu 31040, Taiwan
关键词
glucose biosensors; (3-mercaptopropyl)trimethoxysilane; polyaniline; permselective membranes;
D O I
10.1016/j.snb.2007.12.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The materials (3-mercaptopropyl)trimethoxysilane (MPTMS) sol-gel and non-conducting polyaniline (PAn) were prepared for coating on two different amperometric biosensors fabricated by the immobilization of glucose oxidase (GOx) in conducting polyaniline (PA) as permselective membranes. A few performance characteristics of the MPTMS and the PAn-modified glucose sensors are comparable. In detecting 1 mM glucose, the biosensors' response times were 11 and 12 s, respectively, and results from the repeating measurements (N=10) showed that R.S.D. = 2.09 and 1.70%, respectively. The detection linearity of the two biosensors was up to 12.5 mM[ with R = 0.9989 and 0.9969. When they were used to detect 0.5 mM of ascorbic acid (AA), uric acid (UA), and acetaminophen at an anodic potential of 0.4 V, current signals were either insignificant or invisible. The PAn-coated glucose sensor exhibited superior sensitivity at 18.91 mu A/(mM cm(2)), and a maximum current density of 3.70 mA/cm(2). GOx in the MPTMS-modified biosensor presented a stronger affinity to glucose with K-m = 48.87. More importantly, the stability of this biosensor is superior to that of the PAn-modified biosensor and has lasted for almost 5 months. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:533 / 540
页数:8
相关论文
共 31 条
[1]   Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Itzkan, I ;
Feld, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1997, 53 (02) :287-292
[2]   Ruthenium bipyridine complexes for the recognition of glucose [J].
Cary, DR ;
Darrow, CB ;
Lane, SM ;
Peyser, TA ;
Satcher, JH ;
Van Antwerp, WP ;
Nelson, AJ ;
Reynolds, JG .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) :25-32
[3]   ONLINE CHEMILUMINESCENCE ASSAY USING FIA AND FIBER OPTICS FOR URINARY AND BLOOD-GLUCOSE [J].
CATTANEO, MV ;
LUONG, JHT .
ENZYME AND MICROBIAL TECHNOLOGY, 1993, 15 (05) :424-428
[4]   Construction as well as EQCM and SECM characterizations of a novel Nafion/glucose oxidase-glutaraldehyde/poly(thionine)/Au enzyme electrode for glucose sensing [J].
Deng, Chunyan ;
Li, Mingrui ;
Xie, Qingji ;
Liu, Meiling ;
Yang, Qin ;
Xiang, Canhui ;
Yao, Shouzhuo .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :148-157
[5]   Ferrocene and ferrocenyl derivatives in luminescent systems [J].
Fery-Forgues, S ;
Delavaux-Nicot, B .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2000, 132 (03) :137-159
[6]   Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes [J].
Garjonyte, R ;
Malinauskas, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) :445-451
[7]   Amperometric biosensors based on nafion coated screen-printed electrodes for the determination of cholinesterase inhibitors [J].
Gogol, EV ;
Evtugyn, GA ;
Marty, JL ;
Budnikov, HC ;
Winter, VG .
TALANTA, 2000, 53 (02) :379-389
[8]   CHEMICALLY MODIFIED CELLULOSE-ACETATE MEMBRANE FOR BIOSENSOR APPLICATIONS [J].
GUNASINGHAM, H ;
TEO, PYT ;
LAI, YH ;
TAN, SG .
BIOSENSORS, 1989, 4 (06) :349-359
[9]   CHARACTERIZATION OF PERFLUOROSULFONIC ACID POLYMER COATED ENZYME ELECTRODES AND A MINIATURIZED INTEGRATED POTENTIOSTAT FOR GLUCOSE ANALYSIS IN WHOLE-BLOOD [J].
HARRISON, DJ ;
TURNER, RFB ;
BALTES, HP .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2002-2007
[10]   Application of SiO2-poly(dimethylsiloxane) hybrid material in the fabrication of amperometric biosensor [J].
Ho, Wei-Jen ;
Yuan, Chiun-Jye ;
Reiko, Ohara .
ANALYTICA CHIMICA ACTA, 2006, 572 (02) :248-252