A Molecularly Imprinted Polymer (MIP)-Coated Microbeam MEMS Sensor for Chemical Detection

被引:5
作者
Holthoff, Ellen L. [1 ]
Li, Lily [2 ]
Hiller, Tobias [2 ]
Turner, Kimberly L. [2 ]
机构
[1] US Army, Res Lab, RDRL SEE E, Adelphi, MD 20783 USA
[2] Univ Calif Santa Barbara, Dept Mech Engn, Santa Barbara, CA 93106 USA
来源
CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XVI | 2015年 / 9455卷
关键词
Molecular imprinting; microcantilever; xerogel; chemical sensor; explosives detection; PARAMETRIC RESONANCE; SELECTIVE DETECTION; TNT; FREQUENCY;
D O I
10.1117/12.2179694
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, microcantilever-based technology has emerged as a viable sensing platform due to its many advantages such as small size, high sensitivity, and low cost. However, microcantilevers lack the inherent ability to selectively identify hazardous chemicals (e.g., explosives, chemical warfare agents). The key to overcoming this challenge is to functionalize the top surface of the microcantilever with a receptor material (e.g., a polymer coating) so that selective binding between the cantilever and analyte of interest takes place. Molecularly imprinted polymers (MIPs) can be utilized as artificial recognition elements for target chemical analytes of interest. Molecular imprinting involves arranging polymerizable functional monomers around a template molecule followed by polymerization and template removal. The selectivity for the target analyte is based on the spatial orientation of the binding site and covalent or noncovalent interactions between the functional monomer and the analyte. In this work, thin films of sol-gel-derived xerogels molecularly imprinted for TNT and dimethyl methylphosphonate (DMMP), a chemical warfare agent stimulant, have demonstrated selectivity and stability in combination with a fixed-fixed beam microelectromechanical systems (MEMS)-based gas sensor. The sensor was characterized by parametric bifurcation noise-based tracking.
引用
收藏
页数:14
相关论文
共 35 条
  • [1] STATISTICS OF ATOMIC FREQUENCY STANDARDS
    ALLAN, DW
    [J]. PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1966, 54 (02): : 221 - &
  • [2] Combining resonant piezoelectric micromembranes with molecularly imprinted polymers
    Ayela, Cedric
    Vandevelde, Fanny
    Lagrange, Denis
    Haupt, Karsten
    Nicu, Liviu
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (48) : 9271 - 9274
  • [3] A chemical sensor based on a microfabricated cantilever array with simultaneous resonance-frequency and bending readout
    Battiston, FM
    Ramseyer, JP
    Lang, HP
    Baller, MK
    Gerber, C
    Gimzewski, JK
    Meyer, E
    Güntherodt, HJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 77 (1-2) : 122 - 131
  • [4] Brinker C.J., 1989, Sol Gel Science
  • [5] Burgner CB, 2012, PROC IEEE MICR ELECT
  • [6] Burgner C. B., 2011, ASME 2011 INT DES EN
  • [7] Burgner CB., 2010, SOL STAT SENS ACT MI, DOI [10.31438/trf.hh2010.36, DOI 10.31438/TRF.HH2010.36]
  • [8] Development of multichannel quartz crystal microbalances for MIP-based biosensing
    Croux, Dieter
    Weustenraed, Ans
    Pobedinskas, Paulius
    Horemans, Frederik
    Dilien, Hanne
    Haenen, Ken
    Cleij, Thomas
    Wagner, Patrick
    Thoelen, Ronald
    De Ceuninck, Ward
    [J]. PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2012, 209 (05): : 892 - 899
  • [9] Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
    Ekinci, KL
    Yang, YT
    Roukes, ML
    [J]. JOURNAL OF APPLIED PHYSICS, 2004, 95 (05) : 2682 - 2689
  • [10] Statistics of forced thermally activated escape events out of a metastable state: Most probable escape force and escape-force moments
    Evstigneev, Mykhaylo