Effect of absorption of solar radiation in glass-cover(s) on heat transfer coefficients in upward heat flow in single and double glazed flat-plate collectors

被引:39
作者
Akhtar, Naiem [1 ]
Mullick, S. C. [2 ]
机构
[1] Aligarh Muslim Univ, Dept Mech Engn, ZH Coll Engn & Technol, Aligarh 202002, Uttar Pradesh, India
[2] Indian Inst Technol, Ctr Energy Studies, New Delhi 110016, India
关键词
Absorption of solar radiation in glass cover(s); Heat transfer coefficients; Single and double glazed flat plate collectors; GLASS-COVER; TEMPERATURES; COMPUTATION;
D O I
10.1016/j.ijheatmasstransfer.2011.08.048
中图分类号
O414.1 [热力学];
学科分类号
摘要
Absorption of solar radiation in the glass cover(s) of a flat plate solar collector increases the temperature of cover(s) and hence changes the values of convective and radiative heat transfer coefficients. The governing equations for the case of single as well as double glazed collector have been solved for inner and outer surface temperatures of glass cover(s) with/without including the effect of absorption of solar radiation in the glass cover(s), with appropriate boundary conditions. The effects of absorption of solar radiation on inner and outer surface temperatures and consequently on convective and radiative heat transfer coefficients have been studied over a wide range of the independent variables. The values of glass cover temperatures obtained from numerical solutions of heat balance equations with and without including the effect of absorption of solar radiation in the glass cover(s) are compared. For a single glazed collector the increase in glass cover temperature due to absorption of solar radiation could be as high as 6 degrees. The increase in temperatures of first and second glass covers of a double glazed collector could be as high as 14 degrees and 11 degrees, respectively. The effect on the convective heat transfer coefficient between the absorber plate and the first glass cover is substantial. The difference in the values of the convective heat transfer coefficients between the absorber plate and the first glass cover (h(cp1)) of a double glazed collector for the two cases: (i) including the effect of absorption and (ii) neglecting the effect of absorption in glass cover, could be as high as 49%. Correlations for computing the temperatures of inner and outer surfaces of the glass cover(s) of single and double glazed flat plate collectors are developed. The relations developed enable incorporation of the effect of absorption of solar radiation in glass cover(s) in the relations for inner and outer surface temperatures in a simple manner. By making use of the relations developed for inner and outer surface temperatures of glass cover(s) the convective and radiative heat transfer coefficients can be calculated so close to those obtained by making use of surface temperatures of glass cover(s) obtained by numerical solutions of heat balance equations that numerical solutions of heat balance equations are not required. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:125 / 132
页数:8
相关论文
共 10 条
[1]   Computation of glass-cover temperatures and top heat loss coefficient of flat-plate solar collectors with double glazing [J].
Akhtar, N. ;
Mullick, S. C. .
ENERGY, 2007, 32 (07) :1067-1074
[2]   Correlations for surface temperatures of the glass cover for estimation of heat-transfer coefficients in upward heat-flow in solar collectors with single glazing [J].
Akhtar, N ;
Mullick, SC .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :201-206
[3]   Approximate method for computation of glass cover temperature and top heat-loss coefficient of solar collectors with single glazing [J].
Akhtar, N ;
Mullick, SC .
SOLAR ENERGY, 1999, 66 (05) :349-354
[4]   NATURAL-CONVECTION IN ENCLOSED SPACES - REVIEW OF APPLICATION TO SOLAR-ENERGY COLLECTION [J].
BUCHBERG, H ;
CATTON, I ;
EDWARDS, DK .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (02) :182-188
[5]   WIND-RELATED HEAT-LOSSES OF A FLAT-PLATE COLLECTOR [J].
FRANCEY, JLA ;
PAPAIOANNOU, J .
SOLAR ENERGY, 1985, 35 (01) :15-19
[6]  
Hollands K.G.T., 1976, ASME J HEAT TRANSFER, V98, P89
[7]  
Hottel H.C., 1942, T ASME, V64, P94
[8]   AN IMPROVED TECHNIQUE FOR COMPUTING THE TOP HEAT-LOSS FACTOR OF A FLAT-PLATE COLLECTOR WITH A SINGLE GLAZING [J].
MULLICK, SC ;
SAMDARSHI, SK .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (04) :262-267
[9]   EMITTANCE FROM STAGNATION TEMPERATURE STUDY [J].
NAGAR, VK ;
VAISHYA, JS ;
BHIDE, VG .
SOLAR ENERGY, 1984, 32 (05) :633-636
[10]   ANALYTICAL EQUATION FOR THE TOP HEAT-LOSS FACTOR OF A FLAT-PLATE COLLECTOR WITH DOUBLE GLAZING [J].
SAMDARSHI, SK ;
MULLICK, SC .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1991, 113 (02) :117-122