Biological variation data for kidney function related parameter: serum beta trace protein, creatinine and cystatin C from 22 apparently healthy Turkish subjects

被引:6
作者
Baysoy, Anil [1 ]
Karakoyun, Inanc [1 ]
Arslan, Fatma Demet [1 ]
Basok, Banu Isbilen [1 ]
Colak, Ayfer [1 ]
Duman, Can [2 ]
机构
[1] Univ Hlth Sci, Tepecik Training & Res Hosp, Dept Med Biochem, Gaziler St 468, TR-35170 Izmir, Turkey
[2] Univ Demokrasi, Dept Med Biochem, Izmir, Turkey
关键词
beta trace protein; biological variation; glomerular filtration rate; reference change values; GLOMERULAR-FILTRATION-RATE; INTRAINDIVIDUAL VARIATION; CLINICAL-CHEMISTRY; CRITICAL-APPRAISAL; MARKER; GFR; CHECKLIST; STANDARD; PROJECT; DISEASE;
D O I
10.1515/cclm-2021-0543
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Biological variation is defined as the variation in analytical concentration between and within individuals, and being aware of this biological variation is important for understanding disease dynamics. The aim of our study is to calculate the within-subject (CVI) and between-subject (CVG) biological variations of serum creatinine, cystatin C and Beta trace protein (BTP), as well as the reference change value (RCV) and individuality indexes (II), which are used to calculate the glomerular filtration rate while evaluating kidney damage. Methods Blood samples were collected from 22 healthy volunteers for 10 consecutive weeks and stored at -80 degrees C until the day of analysis. While the analysis for serum creatinine was performed colorimetrically with the kinetic jaffe method, the nephelometric method was employed for cystatin C and BTP measurements. All analyses were carried out in a single session for each test. Results Analytical coefficient of variation (CVA) for serum creatinine, cystatin C and beta trace protein was 5.56, 3.48 and 5.37%, respectively. CVI and CVG: for serum creatinine: 3.31, 14.50%, respectively, for cystatin C: 3.15, 12.24%, respectively, for BTP: 9.91, 14.36%, respectively. RCV and II were calculated as 17.94%, 0.23 for serum creatinine, 13.01%, 0.26 for cystatin C, 31.24%, 0.69 for BTP, respectively. Conclusions According to the data obtained in our study, serum creatinine and cystatin C show high individuality, therefore we think that the use of RCV instead of reference ranges would be appropriate. Although II is found to be low for BTP, more studies are needed to support this finding.
引用
收藏
页码:584 / 592
页数:9
相关论文
共 37 条
[1]   The Biological Variation Data Critical Appraisal Checklist: A Standard for Evaluating Studies on Biological Variation [J].
Aarsand, Aasne K. ;
Roraas, Thomas ;
Fernandez-Calle, Pilar ;
Ricos, Carmen ;
Diaz-Garzon, Jorge ;
Jonker, Niels ;
Perich, Carmen ;
Gonzalez-Lao, Elisabet ;
Carobene, Anna ;
Minchinela, Joana ;
Coskun, Abdurrahman ;
Simon, Margarita ;
Alvarez, Virtudes ;
Bartlett, William A. ;
Fernandez-Fernandez, Pilar ;
Boned, Beatriz ;
Braga, Federica ;
Corte, Zoraida ;
Aslan, Berna ;
Sandberg, Sverre .
CLINICAL CHEMISTRY, 2018, 64 (03) :501-514
[2]  
Aarsand AK., EFLM BIOL VARIATION
[3]   Intra-individual variation in creatinine and cystatin C [J].
Bandaranayake, Niluka ;
Ankrah-Tetteh, Thelma ;
Wijeratne, Sethsiri ;
Swaminathan, Ramasamyiyer .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (09) :1237-1239
[4]   A checklist for critical appraisal of studies of biological variation [J].
Bartlett, William A. ;
Braga, Federica ;
Carobene, Anna ;
Coskun, Abdurrahman ;
Prusa, Richard ;
Fernandez-Calle, Pilar ;
Roraas, Thomas ;
Jonker, Neils ;
Sandberg, Sverre .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (06) :879-885
[5]   Comparison of Measured GFR, Serum Creatinine, Cystatin C, and Beta-Trace Protein to Predict ESRD in African Americans With Hypertensive CKD [J].
Bhavsar, Nrupen A. ;
Appel, Lawrence J. ;
Kusek, John W. ;
Contreras, Gabriel ;
Bakris, George ;
Coresh, Josef ;
Astor, Brad C. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2011, 58 (06) :886-893
[6]   β-Trace protein -: A marker of kidney function in children:: "Original research communication-clinical investigation" [J].
Boekenkamp, Arend ;
Franke, Ingo ;
Schlieber, Michael ;
Dueker, Gesche ;
Schmitt, Joachim ;
Buderus, Stefan ;
Lentze, Michael J. ;
Stoffel-Wagner, Birgit .
CLINICAL BIOCHEMISTRY, 2007, 40 (13-14) :969-975
[7]   European Biological Variation Study (EuBIVAS): Within- and Between-Subject Biological Variation Data for 15 Frequently Measured Proteins [J].
Carobene, Anna ;
Aarsand, Aasne K. ;
Guerra, Elena ;
Bartlett, William A. ;
Coskun, Abdurrahman ;
Diaz-Garzon, Jorge ;
Fernandez-Calle, Pilar ;
Jonker, Niels ;
Locatelli, Massimo ;
Sandberg, Sverre ;
Ceriotti, Ferruccio ;
Barla, Gerhard ;
Cajano, Giulia ;
Plebani, Mario ;
Roraas, Thomas ;
Solvik, Una Orvim ;
Sylte, Marit Sverresdorter ;
Serteser, Mustafa ;
Tosato, Francesca ;
Unsal, Ibrahim .
CLINICAL CHEMISTRY, 2019, 65 (08) :1031-1041
[8]   The EuBIVAS Project: Within- and Between-Subject Biological Variation Data for Serum Creatinine Using Enzymatic and Alkaline Picrate Methods and Implications for Monitoring [J].
Carobene, Anna ;
Marino, Irene ;
Coskun, Abdurrahman ;
Serteser, Mustafa ;
Unsal, Ibrahim ;
Guerra, Elena ;
Bartlett, William A. ;
Sandberg, Sverre ;
Aarsand, Aasne Karine ;
Sylte, Marit Sverresdotter ;
Roraas, Thomas ;
Solvik, Una Orvim ;
Fernandez-Calle, Pilar ;
Diaz-Garzon, Jorge ;
Tosato, Francesca ;
Plebani, Mario ;
Jonker, Niels ;
Barla, Gerhard ;
Ceriotti, Ferruccio .
CLINICAL CHEMISTRY, 2017, 63 (09) :1527-1536
[9]   Sample collections from healthy volunteers for biological variation estimates' update: a new project undertaken by the Working Group on Biological Variation established by the European Federation of Clinical Chemistry and Laboratory Medicine [J].
Carobene, Anna ;
Strollo, Marta ;
Jonker, Niels ;
Barla, Gerhard ;
Bartlett, William A. ;
Sandberg, Sverre ;
Sylte, Marit Sverresdotter ;
Roraas, Thomas ;
Solvik, Una Orvim ;
Fernandez-Calle, Pilar ;
Diaz-Garzon, Jorge ;
Tosato, Francesca ;
Plebani, Mario ;
Coskun, Abdurrahman ;
Serteser, Mustafa ;
Unsal, Ibrahim ;
Ceriotti, Ferruccio .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (10) :1599-1608
[10]   Evaluation of the impact of standardization process on the quality of serum creatinine determination in Italian laboratories [J].
Carobene, Anna ;
Ceriotti, Ferruccio ;
Infusino, Ilenia ;
Frusciante, Erika ;
Panteghini, Mauro .
CLINICA CHIMICA ACTA, 2014, 427 :100-106