Electrochemical Determination of Oxidative Damaged DNA with High Sensitivity and Stability Using a Nanocarbon Film

被引:21
作者
Kato, Dai [1 ]
Komoriya, Mayuri [2 ]
Nakamoto, Kohei [2 ]
Kurita, Ryoji [1 ]
Hirono, Shigeru [3 ]
Niwa, Osamu [3 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058566, Japan
[2] Univ Tsukuba, Tsukuba, Ibaraki 3058571, Japan
[3] MES Afty Corp, Tokyo 1920918, Japan
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; SPUTTERED CARBON-FILM; 8-HYDROXY-2'-DEOXYGUANOSINE; 8-OXO-2-DEOXYGUANOSINE; METHODOLOGY; GUANOSINE; ELECTRODE; LESIONS; STRESS; 8-OHDG;
D O I
10.2116/analsci.27.703
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe the electrochemical determination of oxidative damaged DNA by using a nanocarbon film electrode combined with a high performance liquid chromatography (HPLC) system. The nanocarbon film was formed by employing the electron cyclotron resonance sputtering method, and has a nano-crystalline sp(2) and sp(3) mixed bond structure with an atomically flat surface. This film electrode provided the high electrode activity and stability needed to quantitatively detect oxidative damaged DNA, 8-hydroxy-2'-deoxyguanosine (8-OHdG), by direct electrochemical oxidation. The coefficient of variation (C.V.) value of 1 mu M 8-OHdG at our film electrode was 0.75% (n = 12), which constitutes superior reproducibility to that of a conventional glassy carbon (GC) electrode (9.28%, n = 12) in flow-injection analysis. This was because the nanocarbon film suppressed fouling for the oxidized product of 8-OHdG owing to its hydrophilically ultraflat and chemically stable surface. We also investigated the performance of HPLC with an electrochemical detection (HPLC-ECD) system using our nanocarbon film electrode. The detection limit for 8-OHdG at the nanocarbon film electrode was 3 nM, which was superior to the detection limit of the GC electrode (7.2 nM). Furthermore, this electrode was more suitable for use in a urinary 8-OHdG experiment than the GC electrode. The concentration of urinary 8-OHdG in the urinary sample was 8.30 nM. These results indicate that this HPLC-ECD system with our nanocarbon film electrode enables us to realize an accurate, sensitive, reproducible and easy to use analysis technique.
引用
收藏
页码:703 / 707
页数:5
相关论文
共 31 条
[1]   Assessing biomarkers of oxidative stress: Analysis of guanosine and oxidized guanosine nucleotide triphosphates by high performance liquid chromatography with electrochemical detection [J].
Bolin, Celeste ;
Cardozo-Pelaez, Fernando .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2) :121-130
[2]   Increased oxidative DNA damage, as assessed by urinary 8-hydroxy-2′-deoxyguanosine concentrations, and serum redox status in persons exposed to mercury [J].
Chen, CY ;
Qu, LY ;
Li, B ;
Xing, L ;
Jia, G ;
Wang, TC ;
Gao, YX ;
Zhang, PQ ;
Li, M ;
Chen, W ;
Chai, ZF .
CLINICAL CHEMISTRY, 2005, 51 (04) :759-767
[3]  
Cooke MS, 2008, FREE RADICAL RES, V42, pS102
[4]   Measurement and meaning of oxidatively modified DNA lesions in urine [J].
Cooke, Marcus S. ;
Olinski, Ryszard ;
Loft, Steffen .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2008, 17 (01) :3-14
[5]   DNA repair is responsible for the presence of oxidatively damaged DNA lesions in urine [J].
Cooke, MS ;
Evans, MD ;
Dove, R ;
Rozalski, R ;
Gackowski, D ;
Siomek, A ;
Lunec, J ;
Olinski, R .
MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 2005, 574 (1-2) :58-66
[6]   Methodology for urinary 8-hydroxy-2′-deoxyguanosine analysis by HPLC with electrochemical detection [J].
de Martinis, BS ;
Bianchi, MDLP .
PHARMACOLOGICAL RESEARCH, 2002, 46 (02) :129-131
[7]   Assay for the determination of urinary 8-hydroxy-2'deoxyguanosine by high-performance liquid chromatography with electrochemical detection [J].
Germadnik, D ;
Pilger, A ;
Rudiger, HW .
JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (02) :399-403
[8]   Direct electrochemical detection of DNA methylation for retinoblastoma and CpG fragments using a nanocarbon film [J].
Goto, Keisuke ;
Kato, Dai ;
Sekioka, Naoyuki ;
Ueda, Akio ;
Hirono, Shigeru ;
Niwa, Osamu .
ANALYTICAL BIOCHEMISTRY, 2010, 405 (01) :59-66
[9]   A reliable assessment of 8-oxo-2-deoxyguanosine levels in nuclear and mitochondrial DNA using the sodium iodide method to isolate DNA [J].
Hamilton, ML ;
Guo, ZM ;
Fuller, CD ;
Van Remmen, H ;
Ward, WF ;
Austad, SN ;
Troyer, DA ;
Thompson, I ;
Richardson, A .
NUCLEIC ACIDS RESEARCH, 2001, 29 (10) :2117-2126
[10]   Analysis of 8-hydroxy-2′-deoxyguanosine in urine using high-performance liquid chromatography-electrospray tandem mass spectrometry [J].
Harri, Minna ;
Kasai, Hiroshi ;
Mori, Toshiaki ;
Tornaeus, Jarkko ;
Savela, Kirsti ;
Peltonen, Kimmo .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2) :242-246