A gold nanoparticle-dye/poly(3-aminobenzylamine)/two dimensional MoSe2/graphene oxide electrode towards label-free electrochemical biosensor for simultaneous dual-mode detection of cancer antigen 15-3 and microRNA-21

被引:57
作者
Pothipor, Chammari [1 ,2 ,3 ]
Bamrungsap, Suwussa [4 ]
Jakmunee, Jaroon [1 ,3 ,5 ]
Ounnunkad, Kontad [1 ,3 ,5 ,6 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Grad Sch, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Fac Sci, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
[4] Natl Sci & Technol Dev Agcy NSTDA, Natl Nanotechnol Ctr NANOTEC, Pathum Thani 12120, Thailand
[5] Chiang Mai Univ, Res Ctr Chem Dev Hlth Promoting Prod Northern Res, Chiang Mai 50200, Thailand
[6] Chiang Mai Univ, Ctr Excellence Mat Sci & Technol, Chiang Mai 50200, Thailand
关键词
Breast cancer biomarker; Label-free electrochemical biosensor; Simultaneous detection; Dual-mode biosensor; TUMOR-MARKERS; CARBON ELECTRODE; BIOMARKERS; IMMUNOSENSOR; IMMUNOASSAY; SPECTROSCOPY; FILM; CEA;
D O I
10.1016/j.colsurfb.2021.112260
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A dual-mode electrochemical biosensor is successfully developed for simultaneous detection of two different kinds of breast cancer biomarkers, namely cancer antigen 15-3 (CA 15-3) and microRNA-21 (miRNA-21), for the first time. The sensor composes of a poly(3-aminobenzylamine)/two-dimensional (2D) molybdenum selenide/graphene oxide nanocomposite modified two-screen-printed carbon electrode array (dual electrode), functionalized individually with 2,3-diaminophenazine-gold nanoparticles and toluidine blue-gold nanoparticles. Both kinds of the redox probe-gold nanoparticles are employed as signaling molecules and supports for immobilization of anti-CA 15-3 antibodies and capture DNA-21 probes, respectively. Due to the good conductivity and high surface-to-volume ratio of the nanocomposite, high amount of the antibodies and capture probes can be immobilized on the modified dual-electrode, giving the efficient duplex detection. Consequently, the biosensor provides good selectivity, and high sensitivity for the dual target analyte detection. The experimental results show that this label-free biosensor exhibits good linear responses to the concentrations of both target analytes with the limits of detection (LODs) of 0.14 U mL(-1) and 1.2 fM for CA 15-3 and miRNA-21, respectively. This assay strategy has a great potential to be further developed for the simultaneous detection of a variety of miRNAs and protein biomarkers for point-of-care (POC) diagnostic applications.
引用
收藏
页数:9
相关论文
共 60 条
[1]   An electrochemical biosensor based on a graphene oxide modified pencil graphite electrode for direct detection and discrimination of double-stranded DNA sequences [J].
Ahmadi, Mehran ;
Ahour, Fatemeh .
ANALYTICAL METHODS, 2020, 12 (37) :4541-4550
[2]   Ultrasensitive electrochemiluminescence immunoassay for simultaneous determination of CA125 and CA15-3 tumor markers based on PAMAM-sulfanilic acid-Ru(bpy)32+ and PAMAM-CdTe@CdS nanocomposite [J].
Babamiri, Bahareh ;
Hallaj, Rahman ;
Salimi, Abdollah .
BIOSENSORS & BIOELECTRONICS, 2018, 99 :353-360
[3]   Two-Dimensional Materials in Biosensing and Healthcare: From In Vitro Diagnostics to Optogenetics and Beyond [J].
Bolotsky, Adam ;
Butler, Derrick ;
Dong, Chengye ;
Gerace, Katy ;
Glayin, Nicholas R. ;
Muratore, Christopher ;
Robinson, Joshua A. ;
Ebrahimi, Aida .
ACS NANO, 2019, 13 (09) :9781-9810
[4]   A Bifunctional Nanosilver-Reduced Graphene Oxide Nanocomposite for Label-Free Electrochemical Immunosensing [J].
Chanarsa, Supakeit ;
Jakmunee, Jaroon ;
Ounnunkad, Kontad .
FRONTIERS IN CHEMISTRY, 2021, 9
[5]   Electrochemical detection of the disease marker human chitinase-3-like protein 1 by matching antibody-modified gold electrodes as label-free immunosensors [J].
Chaocharoen, Wethaka ;
Suginta, Wipa ;
Limbut, Warakorn ;
Ranok, Araya ;
Numnuam, Apon ;
Khunkaewla, Panida ;
Kanatharana, Proespichaya ;
Thavarungkul, Panote ;
Schulte, Albert .
BIOELECTROCHEMISTRY, 2015, 101 :106-113
[6]   Simply and sensitively simultaneous detection hepatocellular carcinoma markers AFP and miRNA-122 by a label-free resonance light scattering sensor [J].
Chen, Feng ;
Zhang, Feng ;
Liu, Yi ;
Cai, Changqun .
TALANTA, 2018, 186 :473-480
[7]   Multiplexed electrochemical immunoassay of biomarkers using chitosan nanocomposites [J].
Chen, Xia ;
Ma, Zhanfang .
BIOSENSORS & BIOELECTRONICS, 2014, 55 :343-349
[8]   Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites [J].
Chen, Xia ;
Jia, Xinle ;
Han, Jingman ;
Ma, Jie ;
Ma, Zhanfang .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :356-361
[9]   Electrochemically controlled detection of adrenaline on poly(2-aminobenzylamine) thin films by surface plasmon resonance spectroscopy and quartz crystal microbalance [J].
Chuekachang, Sopis ;
Janmanee, Rapiphun ;
Baba, Akira ;
Phanichphant, Sukon ;
Sriwichai, Saengrawee ;
Shinbo, Kazunari ;
Kato, Keizo ;
Kaneko, Futao ;
Fukuda, Nobuko ;
Ushijima, Hirobumi .
SURFACE AND INTERFACE ANALYSIS, 2013, 45 (11-12) :1661-1666
[10]   Fabrication of Thin Film from Conducting Polymer/Single Wall Carbon Nanotube Composites for the Detection of Uric Acid [J].
Chuekachang, Sopis ;
Janmanee, Rapiphun ;
Baba, Akira ;
Phanichphant, Sukon ;
Sriwichai, Saengrawee ;
Shinbo, Kazunari ;
Kato, Keizo ;
Kaneko, Futao ;
Fukuda, Nobuko ;
Ushijima, Hirobumi .
MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2013, 580 (01) :1-6