A randomized controlled trial comparing autologous radiolabeled in vivo platelet (PLT) recoveries and survivals of 7-day-stored PLT-rich plasma and buffy coat PLTs from the same subjects

被引:17
作者
Dumont, Larry J. [1 ]
Dumont, Deborah F.
Unger, Zoe M.
Siegel, Alan
Szczepiorkowski, Zbigniew M.
Corson, Jill S.
Jones, Mary Kay
Christoffel, Todd
Pellham, Esther
Bailey, S. Lawrence
Slichter, Sherrill J.
机构
[1] Dartmouth Hitchcock Med Ctr, Ctr Transfus Med Res, Dept Pathol, Lebanon, NH 03756 USA
关键词
STORAGE; VARIABLES; TESTS; VITRO;
D O I
10.1111/j.1537-2995.2010.03007.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: A recent review concluded that there was inadequate evidence to show a difference between buffy coat (BC) and platelet (PLT)-rich plasma (PRP) PLT concentrates prepared from whole blood. We hypothesized that 7-day-stored BC-PLTs would have superior autologous recoveries and survivals compared to PRP-PLTs and that both would meet the Food and Drug Administration (FDA) criteria for poststorage viability. STUDY DESIGN AND METHODS: This was a randomized, crossover study design in healthy subjects who provided informed consent. Each participant donated a unit of whole blood on two occasions. In random order, either BC-PLTs or PC-PLTs were prepared after a 20 +/- 2 degrees C overnight hold of the whole blood. PLTs were stored under standard conditions. On Day 7, fresh PLTs were prepared from 43 mL of autologous whole blood. The fresh PLTs paired with either BC-PLTs or PRP-PLTs were alternately labeled with In-111 or Cr-51 and simultaneously reinfused to determine recoveries and survivals. In vitro assays were performed on Days 1 and 7. RESULTS: Fourteen subjects completed the study at two sites. No differences in poststorage PLT viabilities were observed between BC-PLTs and PRP-PLTs; recovery differences averaged 3.7 +/- 2.4% (+/- SE, p = 0.15) and survival differences averaged 0.48 +/- 0.56 days (p = 0.41). Neither type of PLTs met the current FDA criteria for either poststorage PLT recoveries or survivals. CONCLUSION: We were unable to demonstrate that single-unit BC-PLTs stored for 7 days have superior poststorage viability compared to PRP-PLTs. Failure to meet the minimum FDA criteria for poststorage PLT viability raises questions regarding the acceptance thresholds of these metrics.
引用
收藏
页码:1241 / 1248
页数:8
相关论文
共 21 条
[1]   In vitro and in vivo evaluation of leukoreduced platelets stored for 7 days in CLX containers [J].
AuBuchon, JP ;
Taylor, H ;
Holme, S ;
Nelson, E .
TRANSFUSION, 2005, 45 (08) :1356-1361
[2]   Platelet radiolabeling procedure [J].
AuBuchon J.P. .
TRANSFUSION, 2006, 46 (03) :59S-66S
[3]  
BRECHER ME, 2005, TECHNICAL MANUAL AM, P815
[4]   WBC content of platelet concentrates prepared by the buffy coat method using different processing procedures and storage solutions [J].
de Wildt-Eggen, J ;
Schrijver, JG ;
Bins, M .
TRANSFUSION, 2001, 41 (11) :1378-1383
[5]   Analysis and reporting of platelet kinetic studies [J].
Dumont, Larry J. .
TRANSFUSION, 2006, 46 (03) :67S-73S
[6]   Platelet surface P-selectin measurements in platelet preparations: An international collaborative study [J].
Dumont, LJ ;
VandenBroeke, T ;
Ault, KA .
TRANSFUSION MEDICINE REVIEWS, 1999, 13 (01) :31-42
[7]  
*FOOD DRUG ADM CTR, 2004, WORKSH US RAD PLAT A
[8]   Comparing the efficacy and safety of apheresis and whole blood-derived platelet transfusions: a systematic review [J].
Heddle, Nancy M. ;
Arnold, Donald M. ;
Boye, Diana ;
Webert, Kathryn E. ;
Resz, Ilona ;
Dumont, Larry J. .
TRANSFUSION, 2008, 48 (07) :1447-1458
[9]   A multi-laboratory evaluation of in vitro platelet assays: the tests for extent of shape change and response to hypotonic shock [J].
Holme, S ;
Moroff, G ;
Murphy, S .
TRANSFUSION, 1998, 38 (01) :31-40
[10]   PAIRED COMPARISON OF PLATELET CONCENTRATES PREPARED FROM PLATELET-RICH PLASMA AND BUFFY COATS USING A NEW TECHNIQUE WITH IN-111 AND CR-51 [J].
KEEGAN, T ;
HEATON, A ;
HOLME, S ;
OWENS, M ;
NELSON, E ;
CARMEN, R .
TRANSFUSION, 1992, 32 (02) :113-120