Microbiological surveillance of flexible bronchoscopes after a high-level disinfection with peracetic acid: preliminary results from an Italian teaching hospital

被引:9
作者
Troiano, G. [1 ]
Lo Nostro, A. [2 ]
Calonico, C. [2 ]
Nante, N. [1 ]
Magistri, L. [3 ]
Pulci, M. B. [3 ]
Niccolini, F. [3 ]
机构
[1] Univ Siena, Dept Mol & Dev Med, Area Publ Hlth, Via A Moro 2, I-53100 Siena, Italy
[2] Univ Florence, Hlth Sci Dept, Florence, Italy
[3] Hosp Careggi, Hyg & Hlth Org, Florence, Italy
来源
ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITA | 2019年 / 31卷 / 01期
关键词
Bronchoscopes; disinfection; healthcare-associated infections; INFECTION; STERILIZATION; CONTAMINATION; TRANSMISSION; PREVENTION; GUIDELINES; OUTBREAKS;
D O I
10.7416/ai.2019.2254
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background. Flexible bronchoscopes are heat labile, complex and difficult to clean, and some nosocomial outbreaks related to bronchoscopy have been reported in literature. The aim of our study was to determine, through a systematic monitoring, whether bronchoscopes' cleaning and disinfection procedures have been correctly adopted by health operators. Methods. We conducted a 19 months-long prospective study in the Unit of Pulmonology at Careggi Teaching Hospital (Florence, Italy), analyzing endoscopes that were reprocessed through a high-level disinfection procedure. Samples collection was performed weekly by two trained operators. Results were organized in a database and then exported for descriptive and inferential statistical analysis. Results. From February 2016 to September 2017 we collected 218 samples from bronchoscopes' valves (N=109) and from their inner channels (N=109). Staphylococci were found in 34 samples (15.69% of all samples). Pseudomonas was found in 11 samples (5.04% of all samples). Pseudomonas aeruginosa wasn't found in any sample. Conclusions. Our results came out to be better than similar studies in literature and demonstrated that a correct endoscopes' hygiene should be part of a more complex strategy of surveillance and control of healthcare-associated infections. However, a continuous monitoring of endoscopes could provide a wider view about this problem, and more reliable results.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 25 条
[1]   Contamination of bronchoscopes with Mycobacterium tuberculosis and successful sterilization by low-temperature hydrogen peroxide plasma sterilization [J].
Bär, W ;
de Bär, GM ;
Naumann, A ;
Rüsch-Gerdes, S .
AMERICAN JOURNAL OF INFECTION CONTROL, 2001, 29 (05) :306-311
[2]   Outbreaks of contaminated broncho-alveolar lavage related to intrinsically defective bronchoscopes [J].
Cêtre, JC ;
Nicolle, MC ;
Salord, H ;
Pérol, M ;
Tigaud, S ;
David, G ;
Bourjault, M ;
Vanhems, P .
JOURNAL OF HOSPITAL INFECTION, 2005, 61 (01) :39-45
[3]  
Favero M.S., 1991, DISINFECTION STERILI, P617
[4]   Microbiological monitoring of flexible bronchoscopes after high-level disinfection and flushing channels with alcohol: Results and costs [J].
Gayalda, Laura ;
Rosa Otmo, Ana ;
Hernandez, Raquel ;
Angeles Dominguez, M. ;
Robert Salamonsen, Mathew ;
Ayats, Josefina ;
Alcaide, Fernando ;
Soriano, Ana ;
Rosell, Antoni .
RESPIRATORY MEDICINE, 2015, 109 (08) :1079-1085
[5]   SURVIVAL OF BACTERIA UNDER DRY CONDITIONS - FROM A VIEWPOINT OF NOSOCOMIAL INFECTION [J].
HIRAI, Y .
JOURNAL OF HOSPITAL INFECTION, 1991, 19 (03) :191-200
[6]   Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy [J].
Kovaleva, Julia ;
Peters, Frans T. M. ;
van der Mei, Henny C. ;
Degener, John E. .
CLINICAL MICROBIOLOGY REVIEWS, 2013, 26 (02) :231-254
[7]   Swab Type, Moistening, and Preenrichment for Staphylococcus aureus on Environmental Surfaces [J].
Landers, Timothy F. ;
Hoet, Armando ;
Wittum, Thomas E. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (06) :2235-2236
[8]   American College of Chest Physicians and American Association for Bronchoscopy Consensus Statement - Prevention of flexible bronchoscopy-associated infection [J].
Mehta, AC ;
Prakash, UBS ;
Garland, R ;
Haponik, E ;
Moses, L ;
Schaffner, W ;
Silvestri, G .
CHEST, 2005, 128 (03) :1742-1755
[9]   Inconsistencies in endoscope-reprocessing and infection-control guidelines: The importance of endoscope drying [J].
Muscarella, Lawrence F. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (09) :2147-2154
[10]  
Muscarella LF, 1996, INFECT CONT HOSP EP, V17, P183