Indoor air particles and bioaerosols before and after renovation of moisture-damaged buildings:: The effect on biological activity and microbial flora

被引:31
作者
Huttunen, Kati [1 ]
Rintala, Helena [1 ]
Hirvonen, Maija-Riitta [1 ,2 ]
Vepsalainen, Asko [1 ]
Hyvarinen, Anne [1 ]
Meklin, Teija [1 ,3 ]
Toivola, Mika [1 ,4 ]
Nevalainen, Aino [1 ]
机构
[1] Natl Publ Hlth Inst, Dept Environm Hlth, FI-70701 Kuopio, Finland
[2] Univ Kuopio, Dept Environm Sci, FI-70211 Kuopio, Finland
[3] Technol Ctr Teknia Ltd, FI-70211 Kuopio, Finland
[4] Outotec Res Oy, FI-28101 Pori, Finland
关键词
moisture damage; microbes; particles; inflammation; toxicity;
D O I
10.1016/j.envres.2008.02.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many building-related health problems coincide with moisture damage and mold growth within a building. Their elimination is assumed to improve indoor air quality. The aim of this study was to follow the success of remediation in two individual buildings by analyzing the microbial flora and immunotoxicological activity of filter samples. We compare results from samples collected from indoor air in the moisture-damaged buildings before and after renovation and results from matched reference buildings and outdoor air. The microbial characteristics of the samples were studied by analyzing ergosterol content and determining the composition of fungal flora with quantitative polymerase chain reaction (QPCR). In addition, the concentrations of particles were monitored with optical particle counter (OPC). The immunotoxicological activity of collected particle samples was tested by exposing mouse macrophages (RAW264.7) for 24h to particle suspension extracted from the filters, and measuring the viability of the exposed cells (MTT-test) and production of inflammatory mediators (nitric oxide, IL-6 and TNF alpha) in cell culture medium by enzyme-linked immunoassay (ELISA). The results show that for Location I the renovation decreased the immunotoxicological activity of the particles collected from damaged building, whereas no difference was detected in the corresponding samples collected from the reference building. Interestingly, only slight differences were seen in the concentration of fungi. In the Location 2, a decrease was seen in the concentration of fungi after the renovation, whereas no effect on the immunotoxicological responses was detected. In this case, the immunotoxicological responses to the indoor air samples were almost identical to those caused by the samples from outdoor air. This indicates that the effects of remediation on the indoor air quality may not necessarily be readily measurable either with microbial or toxicological parameters. This may be associated with different spectrum of harmful agents in different mold and moisture-damaged buildings. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 35 条
[1]   Improved health after intervention in a school with moisture problems [J].
Åhman, M ;
Lundin, A ;
Musabasic, V ;
Söderman, E .
INDOOR AIR, 2000, 10 (01) :57-62
[2]   Inflammatory potential of dust from waste handling facilities measured as IL-8 secretion from lung epithelial cells in vitro [J].
Allermann, L ;
Poulsen, OM .
ANNALS OF OCCUPATIONAL HYGIENE, 2000, 44 (04) :259-269
[3]   Fungal fragments as indoor air biocontaminants [J].
Górny, RL ;
Reponen, T ;
Willeke, K ;
Schmechel, D ;
Robine, E ;
Boissier, M ;
Grinshpun, SA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2002, 68 (07) :3522-3531
[4]   Airborne fungal fragments and allergenicity [J].
Green, Brett J. ;
Tovey, Euan R. ;
Sercombe, Jason K. ;
Blachere, Francoise M. ;
Beezhold, Donald H. ;
Schmechel, Detlef .
MEDICAL MYCOLOGY, 2006, 44 :S245-S255
[5]   ANALYSIS OF NITRATE, NITRITE, AND [N-15]-LABELED NITRATE IN BIOLOGICAL-FLUIDS [J].
GREEN, LC ;
WAGNER, DA ;
GLOGOWSKI, J ;
SKIPPER, PL ;
WISHNOK, JS ;
TANNENBAUM, SR .
ANALYTICAL BIOCHEMISTRY, 1982, 126 (01) :131-138
[6]   DUST AND THE SICK BUILDING SYNDROME [J].
GYNTELBERG, F ;
SUADICANI, P ;
NIELSEN, JW ;
SKOV, P ;
VALBJORN, O ;
NIELSEN, PA ;
SCHNEIDER, T ;
JORGENSEN, O ;
WOLKOFF, P ;
WILKINS, CK ;
GRAVESEN, S ;
NORN, S .
INDOOR AIR, 1994, 4 (04) :223-238
[7]   Quantitative PCR analysis of selected Aspergillus, Penicillium and Paecilomyces species [J].
Haugland, RA ;
Varma, M ;
Wymer, LJ ;
Vesper, SJ .
SYSTEMATIC AND APPLIED MICROBIOLOGY, 2004, 27 (02) :198-210
[8]   Nitric oxide and proinflammatory cytokines in nasal lavage fluid associated with symptoms and exposure to moldy building microbes [J].
Hirvonen, MR ;
Ruotsalainen, M ;
Roponen, M ;
Hyvärinen, A ;
Husman, T ;
Kosma, VM ;
Komulainen, H ;
Savolainen, K ;
Nevalainen, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (06) :1943-1946
[9]  
Husman T, 1996, SCAND J WORK ENV HEA, V22, P5, DOI 10.5271/sjweh.103
[10]   Production of proinflammatory mediators by indoor air bacteria and fungal spores in mouse and human cell lines [J].
Huttunen, K ;
Hyvärinen, A ;
Nevalainen, A ;
Komulainen, H ;
Hirvonen, MR .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2003, 111 (01) :85-92