Theoretical analysis of a novel integrated energy system formed by a microturbine and a exhaust fired single-double effect absorption chiller

被引:0
|
作者
Medrano, M [1 ]
Mauzey, J [1 ]
McDonell, V [1 ]
Samuelsen, S [1 ]
Boer, D [1 ]
机构
[1] Univ Calif Irvine, Adv Power & Energy Program, Irvine, CA 92697 USA
来源
Proceedings of ECOS 2005, Vols 1-3: SHAPING OUR FUTURE ENERGY SYSTEMS | 2005年
关键词
Integrated Energy Systems; distributed generation; thermally activated technologies; microturbine; absorption chiller; exhaust fired chiller; single effect-double effect cycle; model;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Integrated Energy Systems (IES) combine a distributed power generation system (DG) such as a microturbine generator (MTG) or a fuel cell with thermally activated technologies (TAT) such as absorption cooling. This integration maximizes the efficiency of energy use by utilizing on-site most of the waste heat generated by DG, and reduces harmful emissions to the environment. This study investigates the energy and exergy performance of an IES. This system is comprised of an MTG with internal recuperator and a novel absorption cooling cycle. The absorption cycle is a single effect-double effect exhaust fired cycle, which increases the heat exchanged from the MTG exhaust gases using two generators at two different levels of temperature. The selection of the DG element, the TAT element and their internal configurations is based upon a real IES commercial unit that has been tested in the APEP-UCI DG testing facilities in Irvine, California. This unit has an electrical power capacity of 28 kW and a cooling capacity of 14 refrigeration tons (49.2 kW). Inputs for the thermodynamic models developed for the MTG and for the absorption cycle are derived from experimental variables that will be controlled in the testing phase. The MTG model is using empirical correlations for key model parameters (pressure ratio, turbine inlet temperature, etc.) from previous studies in order to predict the observed change in performance with part load operation. The calculated mass flow rate and temperature of the exhaust gases are inputs for the absorption cycle model, together with cooling and chilled water inlet temperatures and flow rates. Heat and mass transfer efficiencies along with heat transfer coefficients for the suite of heat exchangers comprising the single-double effect absorption cycle are determined from proprietary testing data provided by the manufacturers.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 50 条
  • [1] Theoretical Analysis of a Novel Integrated Energy System Formed by a Microturbine and an Exhaust Fired Single-Double Effect Absorption Chiller
    Medrano, Marc
    Mauzey, Josh
    McDonell, Vince
    Samuelsen, Scott
    Boer, Dieter
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2006, 9 (01) : 29 - 36
  • [2] Experimental results of a novel integrated energy system formed by a microturbine and an exhaust fired single-double effect absorption chiller
    Nogues, Miquel
    Mauzey, Josh
    Freeman, Aaron
    McDonell, Vince
    Samuelsen, Scott
    Proceedings of the ASME Turbo Expo 2006, Vol 5, Pts A and B, 2006, : 477 - 482
  • [3] Air-Conditioning System Using Single-Double Effect Combined Absorption Chiller
    Yabase, Hajime
    Hirai, Akira
    ADVANCES IN THERMOFLUIDS, 2013, 388 : 133 - +
  • [4] Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller
    Hwang, YH
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 816 - 829
  • [5] ENERGY SAVING ON SOLAR AIR-CONDITIONING SYSTEM USING SINGLE-DOUBLE EFFECT COMBINED ABSORPTION CHILLER AT UNIVERSITAS INDONESIA
    Alhamid, M. Idrus
    Yabase, Hajime
    Saito, Kiyoshi
    Hirai, Akira
    Arnas
    Nasruddin
    Dantoku, Tatsuo
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 1214 - 1221
  • [6] PERFORMANCE ANALYSIS FOR THE CHARACTERISTICS OF DOUBLE/SINGLE EFFECT HYBRID TYPE ABSORPTION CHILLER
    Park, Chan Woo
    You, Da Young
    Kim, Hyoung Jin
    Im, Ik-Tae
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (01) : 23 - 29
  • [7] Operation strategy of a solar-gas fired single/double effect absorption chiller for space cooling in Indonesia
    Alhamid, M., I
    Coronas, Alberto
    Lubis, Arnas
    Ayou, Dereje S.
    Nasruddin
    Saito, Kiyoshi
    Yabase, Hajime
    APPLIED THERMAL ENGINEERING, 2020, 178
  • [8] Theoretical analysis and optimization of a double-effect series-flow-type absorption chiller
    Xu, GP
    Dai, YQ
    Tou, KW
    Tso, CP
    APPLIED THERMAL ENGINEERING, 1996, 16 (12) : 975 - 987
  • [9] Theoretical analysis and optimization of a double-effect parallel-flow-type absorption chiller
    Xu, GP
    Dai, YQ
    APPLIED THERMAL ENGINEERING, 1997, 17 (02) : 157 - 170
  • [10] Energy, exergy, thermoeconomic analysis of a novel multi-generation system based on geothermal, kalina, double effect absorption chiller, and LNG regasification
    Zhang, Lei
    Ahmad, Sayed Fayaz
    Cui, Zhenti
    Al Razgan, Muna
    Awwad, Emad Marous
    Ayassrah, Ahmad Y. A. Bani Ahmad
    Shi, Kwanho
    DESALINATION, 2024, 586