Integration of Structures and Circuits for Dosimetry in a Single CMOS Chip

被引:0
作者
Garcia-Inza, M. [1 ,2 ]
Carbonetto, S. [1 ]
Salaya, G. [1 ]
Martinez Vazquez, I. [1 ]
Faigon, A. [1 ,2 ]
机构
[1] Univ Buenos Aires, Fac Ingn, INTECIN, Device Phys Microelect Lab, Av Paseo Colon 850,C1063ACV, Buenos Aires, DF, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
来源
2016 16TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS) | 2016年
关键词
MOSFET Dosimeter; Radiation Effects; CMOS Sensors; Solid-State Detectors;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the design and fabrication in a standard CMOS process of a chip that gathers several structures and circuits for ionizing radiation dosimetry. It includes already tested performance thick gate oxide transistors of different areas and other experimental circuits such as a fully integrated differential dosimeter, floating gate structures, and various types of differential amplifiers. First experimental results are presented.
引用
收藏
页数:5
相关论文
共 19 条
[1]  
*AAPM, 2005, 87 AAPM
[2]  
[Anonymous], 1998, 63 AAPM
[3]  
[Anonymous], 1994, 46 AAPM
[4]  
Carbonetto S, 2015, PROCEEDINGS OF THE 2015 ARGENTINE SCHOOL OF MICRO-NANOELECTRONICS, TECHNOLOGY AND APPLICATIONS (EAMTA), P17, DOI 10.1109/EAMTA.2015.7237372
[5]   CMOS Differential and Amplified Dosimeter with Field Oxide N-Channel MOSFETs [J].
Carbonetto, S. ;
Garcia-Inza, M. ;
Lipovetzky, J. ;
Carra, M. J. ;
Redin, E. ;
Sambuco Salomone, L. ;
Faigon, A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (06) :3466-3471
[6]   Extension of the Measurement Range of MOS Dosimeters Using Radiation Induced Charge Neutralization [J].
Faigon, Adrian ;
Lipovetzky, Jose ;
Redin, E. ;
Krusczenski, Gonzalo .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (04) :2141-2147
[7]   RADIATION-INDUCED CHARGE NEUTRALIZATION AND INTERFACE-TRAP BUILDUP IN METAL-OXIDE-SEMICONDUCTOR DEVICES [J].
FLEETWOOD, DM .
JOURNAL OF APPLIED PHYSICS, 1990, 67 (01) :580-583
[8]   Switched Bias Differential MOSFET Dosimeter [J].
Garcia-Inza, M. ;
Carbonetto, S. ;
Lipovetzky, J. ;
Carra, M. J. ;
Sambuco Salomone, L. ;
Redin, E. G. ;
Faigon, A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) :1407-1413
[9]   Floating Gate CMOS Dosimeter With Frequency Output [J].
Garcia-Moreno, E. ;
Isern, E. ;
Roca, M. ;
Picos, R. ;
Font, J. ;
Cesari, J. ;
Pineda, A. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (02) :373-378
[10]   SPACE-CHARGE DOSIMETER - GENERAL PRINCIPLES OF A NEW METHOD OF RADIATION DETECTION [J].
HOLMESSI.A .
NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01) :169-179