Passivity-Based Control of Water Pumping System Using BLDC Motor Drive Fed by Solar PV Array with Battery Storage System

被引:6
作者
Shchur, Ihor [1 ]
Lis, Marek [2 ]
Biletskyi, Yurii [1 ]
机构
[1] Lviv Polytech Natl Univ, Dept Elect Mechatron & Comp Controlled Electromec, UA-79013 Lvov, Ukraine
[2] Czestochowa Tech Univ, Fac Elect Engn, PL-35959 Czestochowa, Poland
关键词
solar water pumping system (SWPS); photovoltaic array; brushless DC motor (BLDCM); battery energy storage system (BESS); energy management strategy (EMS); passivity-based control (PBC); interconnection and damping assignment (IDA); ENERGY MANAGEMENT; INTERCONNECTION;
D O I
10.3390/en14238184
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In remote locations, it is advisable to combine solar water pumping with electric energy storage and power supply for other forms of consumption. In such complex systems, individual subsystems feature their own local control, and the general automatic control of the system in different modes of its operation is carried out in accordance with an energy management strategy (EMS). In this paper, the functions of local and general control of the solar water pumping system with battery storage and external power supply are combined in the system of passivity-based control (PBC). The EMS is constructed in such a way that for all modes, only two PBC systems are developed, which are switched depending on the battery's state of charge and the current levels of the two main disturbances-solar irradiation and electrical consumption. For each system, two control influence former (CIF) structures were synthesized and their operation was investigated by computer simulation. Despite the simplicity of CIFs' implementation, due to the introduced interconnection and damping coefficients, such control allows the provision of the required voltage regulation with a static error up to 1%, sufficient quality of transients during disturbances and switching of the system structure, as well as system asymptotic stability.
引用
收藏
页数:25
相关论文
共 34 条
[1]   A review of solar-powered water pumping systems [J].
Aliyu, Mansur ;
Hassan, Ghassan ;
Said, Syed A. ;
Siddiqui, Muhammad U. ;
Alawami, Ali T. ;
Elamin, Ibrahim M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 87 :61-76
[2]  
[Anonymous], 2012, P 2012 ASIA PACIFIC
[3]  
Becherif M., 2010, 2010 IEEE International Energy Conference (ENERGYCON 2010), P664, DOI 10.1109/ENERGYCON.2010.5771764
[4]   Experimental study of energy management of FC/SC hybrid system using the Passivity Based Control [J].
Benmouna, A. ;
Becherif, M. ;
Depature, C. ;
Boulon, L. ;
Depernet, D. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (25) :11583-11592
[5]   Novel Energy Management Technique for Hybrid Electric Vehicle via Interconnection and Damping Assignment Passivity Based Control [J].
Benmouna, Amel ;
Becherif, Mohamed ;
Depernet, Daniel ;
Ebrahim, Mohamed A. .
RENEWABLE ENERGY, 2018, 119 :116-128
[6]  
Benzaouia M., 2020, P 2 INT C EL ENG REN, P855, DOI [10.1007/978-981-15-6259-489, DOI 10.1007/978-981-15-6259-4_89]
[7]  
Durgaprasad R., 2018, INT J ENG RES TECHNO, V7, P389
[8]  
Harsh K., 2020, INT J ENG RES TECHNO, V9, P635, DOI [10.17577/IJERTV9IS060478, DOI 10.17577/IJERTV9IS060478]
[9]   Performance Evaluation of Maximum Power Point Tracking Approaches and Photovoltaic Systems [J].
Islam, Haidar ;
Mekhilef, Saad ;
Shah, Noraisyah Binti Mohamed ;
Soon, Tey Kok ;
Seyedmahmousian, Mehdi ;
Horan, Ben ;
Stojcevski, Alex .
ENERGIES, 2018, 11 (02)
[10]   Optimally Tuned Interleaved Luo Converter for PV Array Fed BLDC Motor Driven Centrifugal Pumps Using Whale Optimization Algorithm-A Resilient Solution for Powering Agricultural Loads [J].
Jegha, A. Darcy Gnana ;
Subathra, M. S. P. ;
Kumar, Nallapaneni Manoj ;
Ghosh, Aritra .