Scapulohumeral rhythm in shoulders with reverse shoulder arthroplasty

被引:51
作者
Walker, David [1 ]
Matsuki, Keisuke [2 ]
Struk, Aimee M. [3 ]
Wright, Thomas W. [3 ]
Banks, Scott A. [1 ]
机构
[1] Univ Florida, Dept Mech Engn, Gainesville, FL 32611 USA
[2] Teikyo Univ, Chiba Med Ctr, Dept Orthopaed Surg, Ichihara, Chiba, Japan
[3] Univ Florida, Dept Orthopaed & Rehabil, Gainesville, FL USA
关键词
Reverse total shoulder arthroplasty; rehabilitation; implant design; surgical technique; shoulder motion; scapulohumeral rhythm; CUFF TEAR ARTHROPATHY; IMPINGEMENT; PROSTHESIS; ARTHRITIS; DESIGN; MOTION; REPLACEMENT; KINEMATICS; ELEVATION; SENSORS;
D O I
10.1016/j.jse.2014.11.043
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Little is known about kinematic function of reverse total shoulder arthroplasty (RTSA). Scapulohumeral rhythm (SHR) is a common metric for assessing muscle function and shoulder joint motion. The purpose of this study was to compare SHR in shoulders with RTSA to normal shoulders. Methods: Twenty-eight subjects, more than 12 months after unilateral RTSA, were recruited for an Institutional Review Board-approved study. Subjects performed arm abduction in the coronal plane with and without a 1.4-kg hand-held weight. Three-dimensional model-image registration techniques were used to measure orientation and position for the humerus and scapula from fluoroscopic images. Analysis of variance and Tukey tests were used to assess groupwise and pairwise differences. Results: SHR in RTSA shoulders (1.3: 1) was significantly lower than in normal shoulders (3: 1). Below 30 degrees abduction, RTSA and normal shoulders show a wide range of SHR (1.3: 1 to 17: 1). Above 30 degrees abduction, SHR in RTSA shoulders was 1.3: 1 for unweighted abduction and 1.3: 1 for weighted abduction. Maximum RTSA shoulder abduction in weighted trials was lower than in unweighted trials. SHR variability in RTSA shoulders decreased with increasing arm elevation. Conclusion: RTSA shoulders show kinematics that are significantly different from normal shoulders. SHR in RTSA shoulders was significantly lower than in normal shoulders, indicating that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm. With these observations, it may be possible to improve rehabilitation protocols, with particular attention to the periscapular muscles, and implant design or placement to optimize functional outcomes in shoulders with RTSA. Level of evidence: Basic Science, Kinesiology. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1129 / 1134
页数:6
相关论文
共 26 条
[1]   Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[2]   Grammont reverse prosthesis: Design, rationale, and biomechanics [J].
Boileau, P ;
Watkinson, DJ ;
Hatzidakis, AM ;
Balg, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :147S-161S
[3]   Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplasty [J].
Boileau, Pascal ;
Watkinson, Duncan ;
Hatzidakis, Armodios M. ;
Hovorka, Istvan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) :527-540
[4]  
Cordasco Frank A, 2010, HSS J, V6, P30, DOI 10.1007/s11420-009-9127-6
[5]   Kinematic evaluation of patients with total and reverse shoulder arthroplasty during rehabilitation exercises with different loads [J].
de Toledo, Joelly Mahnic ;
Loss, Jefferson Fagundes ;
Janssen, Thomas W. ;
van der Scheer, Jan W. ;
Alta, Tjarco D. ;
Willems, W. Jaap ;
Veeger, DirkJan .
CLINICAL BIOMECHANICS, 2012, 27 (08) :793-800
[6]   Shoulder prostheses treating cuff tear arthropathy: a comparative biomechanical study [J].
De Wilde, LF ;
Audenaert, EA ;
Berghs, BM .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) :1222-1230
[7]   Range of Impingement-Free Abduction and Adduction Deficit After Reverse Shoulder Arthroplasty Hierarchy of Surgical and Implant-Design-Related Factors [J].
Gutierrez, Sergio ;
Comiskey, Charles A., IV ;
Luo, Zong-Ping ;
Pupello, Derek R. ;
Frankle, Mark A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) :2606-2615
[8]   Initial glenoid component fixation in "reverse" total shoulder arthroplasty: A biomechanical evaluation [J].
Harman, M ;
Frankle, M ;
Vasey, M ;
Banks, S .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :162S-167S
[9]  
Inman VT, 1944, J BONE JOINT SURG, V26, P1
[10]   How does scapula motion change after reverse total shoulder arthroplasty? - a preliminary report [J].
Kim, Myung-Sun ;
Lim, Keun-Young ;
Lee, Dong-Hyun ;
Kovacevic, David ;
Cho, Nam-Young .
BMC MUSCULOSKELETAL DISORDERS, 2012, 13