Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations

被引:217
作者
Guirao, A [1 ]
Williams, DR
Cox, IG
机构
[1] Univ Murcia, Dept Fis, Lab Opt, E-30071 Murcia, Spain
[2] Univ Rochester, Ctr Visual Sci, Rochester, NY 14627 USA
[3] Bausch & Lomb Inc, Rochester, NY 14692 USA
来源
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION | 2001年 / 18卷 / 05期
关键词
D O I
10.1364/JOSAA.18.001003
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
ideal correcting method, such as a customized contact lens, laser refractive surgery, or adaptive optics, that corrects higher-order aberrations as well as defocus and astigmatism could improve vision. The benefit achieved with this ideal method will be limited by decentration. To estimate the significance of this potential limitation we studied the effect on image quality expected when an ideal correcting method translates or rotates with respect to the eye's pupil. Actual wave aberrations were obtained from ten human eyes for a 7.3-mm pupil with a Shack-Hartmann sensor. We computed the residual aberrations that appear as a result of translation or rotation of an otherwise ideal correction. The model is valid for adaptive optics, contact lenses, and phase plates, but it constitutes only a first approximation to the laser refractive surgery case where tissue removal occurs. Calculations suggest that the typical decentrations will reduce only slightly the optical benefits expected from an ideal correcting method. For typical decentrations the ideal correcting method offers a benefit in modulation 2-4 times higher (1.5-2 times in white light) than with a standard correction of defocus and astigmatism We obtained analytical expressions that show the impact of translation and rotation on individual Zernike terms. These calculations also reveal which aberrations are most beneficial to correct. We provided practical rules to implement a selective correction depending on the amount of decentration. An experimental study was performed with an aberrated artificial eve corrected with an adaptive optics system, validating the theoretical predictions. The results in a keratoconic subject, also corrected with adaptive optics, showed that important benefits are obtained despite decentrations in highly aberrated eyes. (C) 2001 Optical Society of America.
引用
收藏
页码:1003 / 1015
页数:13
相关论文
共 51 条
  • [1] ALVAREZ LW, 1978, J AM OPTOM ASSOC, V49, P24
  • [2] [Anonymous], BIOPHYSICS
  • [3] APPLEGATE RA, 1995, INVEST OPHTH VIS SCI, V36, P36
  • [4] ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY
    ARTAL, P
    MARCOS, S
    NAVARRO, R
    WILLIAMS, DR
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02): : 195 - 201
  • [5] MONOCHROMATIC MODULATION TRANSFER-FUNCTION OF THE HUMAN EYE FOR DIFFERENT PUPIL DIAMETERS - AN ANALYTICAL EXPRESSION
    ARTAL, P
    NAVARRO, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (01): : 246 - 249
  • [6] ARTAL P, 1999, 1999 OSA TECHNICAL D, P232
  • [7] Positioning tolerances for phase plates compensating aberrations of the human eye
    Bará, S
    Mancebo, T
    Moreno-Barriuso, E
    [J]. APPLIED OPTICS, 2000, 39 (19) : 3413 - 3420
  • [8] OPTICAL QUALITY OF HUMAN EYE
    CAMPBELL, FW
    GUBISCH, RW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1966, 186 (03): : 558 - +
  • [9] CHARMAN WN, 1983, PROGR RETINAL RES, V2, pCH1
  • [10] Influence of myopia and aging on the optimal spherical aberration of soft contact lenses
    Chateau, N
    Blanchard, A
    Baude, D
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (09): : 2589 - 2596