Simultaneous liver iron and fat measures by magnetic resonance imaging in patients with hyperferritinemia

被引:24
|
作者
Galimberti, Stefania [1 ]
Trombini, Paola [2 ]
Bernasconi, Davide Paolo [1 ]
Redaelli, Irene [3 ]
Pelucchi, Sara [4 ]
Bovo, Giorgio [5 ]
Di Gennaro, Filiberto [6 ]
Zucchini, Nicola [5 ]
Paruccini, Nicoletta [3 ]
Piperno, Alberto [4 ,7 ]
机构
[1] Univ Milano Bicocca, Dept Hlth Sci, Ctr Biostat Clin Epidemiol, Monza, Italy
[2] ICP Sesto S Giovanni Hosp, Internal Med Unit, Milan, Italy
[3] S Gerardo Hosp, Med Phys Unit, Monza, Italy
[4] Univ Milano Bicocca, Dept Hlth Sci, Monza, Italy
[5] S Gerardo Hosp, Clin Pathol Unit, Monza, Italy
[6] S Gerardo Hosp, Clin Radiol Unit, Monza, Italy
[7] S Gerardo Hosp, Ctr Hemochromatosis & Iron Metab Disorders, Monza, Italy
关键词
ferritin; iron; liver; magnetic resonance imaging; steatosis; HEPATIC STEATOSIS; NONINVASIVE ASSESSMENT; METABOLIC SYNDROME; OVERLOAD; DISEASE; MRI; DIAGNOSIS; HEMOCHROMATOSIS; T2-ASTERISK; HISTOLOGY;
D O I
10.3109/00365521.2014.940380
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective. Hyperferritinemia is frequent in chronic liver diseases of any cause, but the extent to which ferritin truly reflects iron stores is variable. In these patients, both liver iron and fat are found in variable amount and association. Liver biopsy is often required to quantify liver fat and iron, but sampling variability and invasiveness limit its use. We aimed to assess single breath-hold multiecho magnetic resonance imaging (MRI) for the simultaneous lipid and iron quantification in patients with hyperferritinemia. Material and methods. We compared MRI results for both iron and fat with their respective gold standards - liver iron concentration and computer-assisted image analysis for steatosis on biopsy. We prospectively studied 67 patients with hyperferritinemia and other 10 consecutive patients were used for validation. We estimated two linear calibration equations for the prediction of iron and fat based on MRI. The agreement between MRI and biopsy was evaluated. Results. MRI showed good performances in both the training and validation samples. MRI information was almost completely in line with that obtained from liver biopsy. Conclusion. Single breath-hold multiecho MRI is an accurate method to obtain a valuable measure of both liver iron and steatosis in patients with hyperferritinemia.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [31] Evaluating the Volumetric Liver Fat Fraction in Patients Referred for Investigation of Hyperferritinemia
    Dervin, Aoife
    Eleftheriou, Perla
    Suri, Deepak
    Trompeter, Sara
    Garbowski, Maciej W.
    St Pierre, Tim
    Porter, John B.
    Drasar, Emma
    BLOOD, 2019, 134
  • [32] Narrative review of magnetic resonance imaging in quantifying liver iron load
    Feng, Qing
    Yi, Jixing
    Li, Tao
    Liang, Bumin
    Xu, Fengming
    Peng, Peng
    FRONTIERS IN MEDICINE, 2024, 11
  • [33] Role of liver magnetic resonance imaging in hyperferritinaemia and the diagnosis of iron overload
    Axel, Ruefer
    Christine, Bapst
    Rudolf, Benz
    Jens, Bremerich
    Nathan, Cantoni
    Laura, Infanti
    Kaveh, Samii
    Mathias, Schmid
    Jean-Paul, Vallee
    SWISS MEDICAL WEEKLY, 2017, 147
  • [34] Measurement and mapping of liver iron concentrations using magnetic resonance imaging
    St Pierre, TG
    Clark, PR
    Chua-Anusorn, W
    COOLEY'S ANEMIA EIGHTH SYMPOSIUM, 2005, 1054 : 379 - 385
  • [35] A robust method for assessment of iron overload in liver by magnetic resonance imaging
    Positano, Vincenzo
    Salani, Benedetta
    Scattini, Barbara
    Santarelli, Maria F.
    Ramazzotti, Anna
    Pepe, Alessia
    Lombardi, Massimo
    Landini, Luigi
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2895 - +
  • [36] Use of magnetic resonance imaging to assess liver iron in a provincial hospital
    Devalia, V.
    Tudor, G.
    Yapp, T.
    Constable, G.
    AMERICAN JOURNAL OF HEMATOLOGY, 2007, 82 (06) : 600 - 601
  • [37] Measurement of liver iron by magnetic resonance imaging in the UK Biobank population
    McKay, Andy
    Wilman, Henry R.
    Dennis, Andrea
    Kelly, Matt
    Gyngell, Michael L.
    Neubauer, Stefan
    Bell, Jimmy D.
    Banerjee, Rajarshi
    Thomas, E. Louise
    PLOS ONE, 2018, 13 (12):
  • [38] Fat and Water Magnetic Resonance Imaging
    Bley, Thorsten A.
    Wieben, Oliver
    Francois, Christopher J.
    Brittain, Jean H.
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 4 - 18
  • [39] Liver iron concentration evaluated by two magnetic methods: Magnetic resonance imaging and magnetic susceptometry
    Carneiro, AAO
    Fernandes, JP
    de Araujo, DB
    Elias, J
    Martinelli, ALC
    Covas, DT
    Zago, MA
    Angulo, IL
    St Pierre, TG
    Baffa, O
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 122 - 128
  • [40] Proton density fat fraction: magnetic resonance imaging applications beyond the liver
    Idilman, Ilkay S.
    Yildiz, A. Elcin
    Karaosmanoglu, Ali Devrim
    Ozmen, Mustafa N.
    Akata, Deniz
    Karcaaltincaba, Musturay
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2022, 28 (01) : 83 - 91