Range of motion of standard and high-flexion posterior stabilized total knee prostheses

被引:215
作者
Kim, YH [1 ]
Sohn, KS [1 ]
Kim, JS [1 ]
机构
[1] Ewha Womans Univ, Dong Dae Mun Hosp, Ctr Joint Replacement, Seoul 110783, South Korea
关键词
D O I
10.2106/JBJS.D.02707
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The restoration of posterior femoral translation has been shown to be an important factor in enhancing knee flexion after total knee arthroplasty. The purpose of this study was to compare the ranges of motion associated with standard and high-flexion posterior stabilized total knee prostheses in patients managed with simultaneous bilateral total knee arthroplasty. Methods: Fifty patients (mean age, sixty-eight years) received a standard fixed-bearing knee prosthesis in one knee and a high-flexion fixed-bearing knee prosthesis in the contralateral knee. Two patients were men, and forty-eight were women. At a mean of 2.1 years postoperatively, the patients were assessed clinically and radiographically with use of the knee-rating systems of the Knee Society and The Hospital for Special Surgery. Results: The mean postoperative Hospital for Special Surgery knee score was 90 points for the knees treated with the standard fixed-bearing prosthesis and 89.4 points for those treated with the high-flexion prosthesis. At the time of the final follow-up, the knees with the standard prosthesis had a mean range of motion of 135.8 degrees (range, 1050 to 1500) and those with a high-flexion prosthesis had a mean range of motion of 138.6 degrees (range, 105 degrees to 150 degrees) (p = 0.41). No knee had aseptic loosening, revision, or osteolysis. Conclusions: After a minimum duration of follow-up of two years, we found no significant differences between the groups with regard to range of motion or clinical and radiographic parameters, except for posterior femoral condylar offset.
引用
收藏
页码:1470 / 1475
页数:6
相关论文
共 13 条
  • [1] Andriacchi T P, 1988, J Arthroplasty, V3 Suppl, pS13, DOI 10.1016/S0883-5403(88)80003-2
  • [2] Anouchi YS, 1996, CLIN ORTHOP RELAT R, P87
  • [3] Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset
    Bellemans, J
    Banks, S
    Victor, J
    Vandenneucker, H
    Moemans, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 50 - 53
  • [4] EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
  • [5] Radiographic analysis of low contact stress meniscal bearing total knee replacements
    Hartford, JM
    Banit, D
    Hall, K
    Kaufer, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (02) : 229 - 234
  • [6] COMPARISON OF 4 MODELS OF TOTAL KNEE-REPLACEMENT PROSTHESES
    INSALL, JN
    RANAWAT, CS
    AGLIETTI, P
    SHINE, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (06) : 754 - 765
  • [7] Comparison of anterior-posterior-glide and rotating-platform low contact stress mobile-bearing total knee arthroplasties
    Kim, YH
    Kim, JS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06) : 1239 - 1247
  • [8] Kim YH, 2001, CLIN ORTHOP RELAT R, P101
  • [9] Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: An in vitro robotic experimental investigation
    Li, G
    Most, E
    Sultan, PG
    Schule, S
    Zayontz, S
    Park, SE
    Rubash, HE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08) : 1721 - 1729
  • [10] LI G, 2003, ADULT KNEE, V2, P1233