Biosensors based on cholinesterase inhibition for insecticides, nerve agents and aflatoxin B1 detection (review)

被引:123
作者
Arduini, Fabiana [1 ,2 ]
Amine, Aziz [3 ]
Moscone, Danila [1 ,2 ]
Palleschi, Giuseppe [1 ,2 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Consorzio Interuniv Biostrutture Biosistemi INBB, I-00136 Rome, Italy
[3] Fac Sci & Tech, Mohammadia, Morocco
关键词
Biosensors; Inhibition; Insecticides; Cholinesterase; Nerve agents; Aflatoxin; SCREEN-PRINTED ELECTRODES; FIELD-EFFECT TRANSISTORS; NIPPOSTRONGYLUS-BRASILIENSIS ACETYLCHOLINESTERASE; ORGANOPHOSPHATE PESTICIDE DETECTION; SURFACE-PLASMON RESONANCE; SELF-ASSEMBLED MONOLAYER; CHEMICAL WARFARE AGENTS; FLOW-INJECTION ANALYSIS; DURUM-WHEAT SAMPLES; ENZYME-INHIBITION;
D O I
10.1007/s00604-010-0317-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present review reports the research carried out during last 9 years on biosensors based on cholinesterase inhibition for nerve agents, organophosphorus and carbammic insecticides, and aflatoxin B-1 detection. Relative applications in environmental and food areas are also reported. Special attention is paid to the optimization of parameters such as enzyme immobilization, substrate concentration, and incubation time in the case of reversible inhibition by aflatoxin B-1 or irreversible inhibition by organophosphorus and carbamic insecticides, and nerve agents in order to optimize and improve the analytical performances of the biosensor. Evaluation of selectivity of the system is also discussed.
引用
收藏
页码:193 / 214
页数:22
相关论文
共 213 条
[1]   GAS-CHROMATOGRAPHIC ANALYSIS OF ORGANOPHOSPHORUS PESTICIDES OF HORTICULTURAL CONCERN [J].
AGUERA, A ;
CONTRERAS, M ;
FERNANDEZALBA, AR .
JOURNAL OF CHROMATOGRAPHY A, 1993, 655 (02) :293-300
[2]   Thick-film biosensors for pesticides produced by screen-printing of graphite-epoxy composite and biocomposite pastes [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :48-57
[3]   Enzyme inhibition-based biosensors for food safety and environmental monitoring [J].
Amine, A ;
Mohammadi, H ;
Bourais, I ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1405-1423
[4]   Electrochemical immunosensor for determination of aflatoxin B1 in barley [J].
Ammida, NHS ;
Micheli, L ;
Palleschi, G .
ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) :159-164
[5]   Development of highly sensitive sensor based on bioengineered acetylcholinesterase immobilized by affinity method [J].
Andreescu, S ;
Fournier, D ;
Marty, JL .
ANALYTICAL LETTERS, 2003, 36 (09) :1865-1885
[6]   Detection of organophosphorus insecticides with immobilized acetylcholinesterase - comparative study of two enzyme sensors [J].
Andreescu, S ;
Avramescu, A ;
Bala, C ;
Magearu, V ;
Marty, JL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (01) :39-45
[7]   Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents [J].
Andreescu, S ;
Noguer, T ;
Magearu, V ;
Marty, JL .
TALANTA, 2002, 57 (01) :169-176
[8]   Immobilization of acetylcholinesterase on screen-printed electrodes: comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides [J].
Andreescu, S ;
Barthelmebs, L ;
Marty, JL .
ANALYTICA CHIMICA ACTA, 2002, 464 (02) :171-180
[9]   Immobilization of enzymes on screen-printed sensors via an histidine tail. Application to the detection of pesticides using modified cholinesterase [J].
Andreescu, S ;
Magearu, V ;
Lougarre, A ;
Fournier, D ;
Marty, JL .
ANALYTICAL LETTERS, 2001, 34 (04) :529-540
[10]  
Andreescu S., 2006, IMMOBILIZATION ENZYM