Single Breath-Hold T1ρ-Mapping of the Heart for Endogenous Assessment of Myocardial Fibrosis

被引:20
|
作者
van Oorschot, Joep W. M. [1 ,2 ]
Visser, Fredy [2 ]
Eikendal, Anouk L. M. [1 ]
Vonken, Evert-jan P. A. [1 ]
Luijten, Peter R. [1 ]
Chamuleau, Steven A. J. [3 ]
Leiner, Tim [1 ]
Zwanenburg, Jaco J. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Heidelberglaan 100, NL-3508 GA Utrecht, Netherlands
[2] Philips Healthcare, Best, Netherlands
[3] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
关键词
cardiac; T-1; rho-mapping; rho; spin-lock; magnetic resonance imaging; endogenous; nature contrast; black-blood; myocardium; heart; CARDIOVASCULAR MAGNETIC-RESONANCE; IN-VIVO; RELAXATION-TIME; ROTATING-FRAME; INFARCTION CHARACTERIZATION; ARTICULAR-CARTILAGE; CONTRAST-MEDIA; MRI; T-1; ENHANCEMENT;
D O I
10.1097/RLI.0000000000000261
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: In this study, we propose a method to acquire high spatial-resolution T-1 rho-maps, which allows bright and black-blood imaging, in a single breath-hold. To validate this innovative method, the reproducibility was tested in phantoms and volunteers. Lastly, the sensitivity and specificity for infarct detection was compared with the criterion standard late gadolinium enhancement (LGE). Methods: T-1 rho-mapping was performed using a T-1 rho-prepared balanced steady-state free precession sequence at 1.5 T and 3 T. Five images with increasing spin-lock preparation times (spin-lock = 0, 10, 20, 30, 40 milliseconds, amplitude = 500 Hz) were acquired with an interval of 3 beats. Black-blood imaging was performed using a double inversion pulse sequence. The method was tested in 2 times 10 healthy volunteers at 1.5 and 3 T and in 9 myocardial infarction patients at 1.5 T. T-1 rho-maps, and LGE images were scored for presence and extent of myocardial scarring. Results: Phantom results show that the proposed T-1 rho-mapping method gives accurate T-1 rho-values. The mean T-1 rho-relaxation time of the myocardium in healthy controls was 52.8 +/- 1.8 milliseconds at 1.5 T and 46.4 +/- 1.8 milliseconds at 3 T. In patients, the T-1 rho of infarcted myocardium was (82.4 +/- 5.2 milliseconds), and the T-1 rho of remote myocardium was (54.2 +/- 2.8 milliseconds; P < 0.0001). Sensitivity of infarct detection on a T-1 rho-map was 70%, with a specificity of 94%, compared with LGE. Conclusions: In this study, we have investigated a method to acquire high spatial-resolution T-1 rho-maps of the heart in a single breath-hold. This method proved to be reproducible and had high specificity compared with LGE and can thus be used for the endogenous detection of myocardial fibrosis in patients with ischemic cardiomyopathy.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 50 条
  • [31] T1 mapping for detection of left ventricular myocardial fibrosis in hypertrophic cardiomyopathy: A preliminary study
    Lu, Minjie
    Zhao, Shihua
    Yin, Gang
    Jiang, Shiliang
    Zhao, Tao
    Chen, Xiuyu
    Tian, Liangxin
    Zhang, Yan
    Wei, Yunqing
    Liu, Qiong
    He, Zuoxiang
    Xue, Hui
    An, Jing
    Shah, Saurabh
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : E225 - E231
  • [32] Native T1 Mapping and Extracellular Volume Mapping for the Assessment of Diffuse Myocardial Fibrosis in Dilated Cardiomyopathy
    Nakamori, Shiro
    Dohi, Kaoru
    Ishida, Masaki
    Goto, Yoshitaka
    Imanaka-Yoshida, Kyoko
    Omori, Taku
    Goto, Itaru
    Kumagai, Naoto
    Fujimoto, Naoki
    Ichikawa, Yasutaka
    Kitagawa, Kakuya
    Yamada, Norikazu
    Sakuma, Hajime
    Ito, Masaaki
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 48 - 59
  • [33] Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment
    Taigang He
    Paul Kirk
    David N Firmin
    Wynnie M Lam
    Winnie CW Chu
    Wing-Yan Au
    Godfrey CF Chan
    Ru San Tan
    Ivy Ng
    Selen Biceroglu
    Yesim Aydinok
    Mark A Fogel
    Alan R Cohen
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 10
  • [34] T1 Mapping for Myocardial Fibrosis by Cardiac Magnetic Resonance Relaxometry - A Comprehensive Technical Review
    Hamilton-Craig, Christian R.
    Strudwick, Mark W.
    Galloway, Graham J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2017, 3
  • [35] T1 Mapping for Diffuse Myocardial Fibrosis A Key Biomarker in Cardiac Disease?
    Moon, James C.
    Treibel, Thomas A.
    Schelbert, Erik B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (14) : 1288 - 1289
  • [36] Adiabatic Inversion Pulses for Myocardial T1 Mapping
    Kellman, Peter
    Herzka, Daniel A.
    Hansen, Michael Schacht
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1428 - 1434
  • [37] Effect of spin-lock frequency on quantitative myocardial T1ρ mapping
    Han, Caiyun
    Xu, Huimin
    Gao, Hui
    Liu, Fang
    Wu, Jian
    Liu, Yan
    Cheng, Yong
    Deng, Wei
    Yue, Xiuzheng
    Wu, Zhigang
    Yu, Yongqiang
    Zhao, Ren
    Han, Yuchi
    Li, Xiaohu
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [38] Histological validation of cardiovascular magnetic resonance T1 mapping markers of myocardial fibrosis in paediatric heart transplant recipients
    Ide, Seiko
    Riesenkampff, Eugenie
    Chiasson, David A.
    Dipchand, Anne I.
    Kantor, Paul F.
    Chaturvedi, Rajiv R.
    Yoo, Shi-Joon
    Grosse-Wortmann, Lars
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19 : 1 - 11
  • [39] Myocardial T1 Mapping in Pediatric and Congenital Heart Disease
    Riesenkampff, Eugenie
    Messroghli, Daniel R.
    Redington, Andrew N.
    Grosse-Wortmann, Lars
    CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (02)
  • [40] Relationship between Measurement Errors in Myocardial T1 Mapping and Heart Rate
    Amano, Yasuo
    Omori, Yuko
    Yanagisawa, Fumi
    Ando, Chisato
    Shinoda, Naoki
    Suzuki, Yasuyuki
    Yamamoto, Hiroshi
    Matsumoto, Naoya
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (04) : 345 - 350