Single Breath-Hold T1ρ-Mapping of the Heart for Endogenous Assessment of Myocardial Fibrosis

被引:20
|
作者
van Oorschot, Joep W. M. [1 ,2 ]
Visser, Fredy [2 ]
Eikendal, Anouk L. M. [1 ]
Vonken, Evert-jan P. A. [1 ]
Luijten, Peter R. [1 ]
Chamuleau, Steven A. J. [3 ]
Leiner, Tim [1 ]
Zwanenburg, Jaco J. M. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Heidelberglaan 100, NL-3508 GA Utrecht, Netherlands
[2] Philips Healthcare, Best, Netherlands
[3] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
关键词
cardiac; T-1; rho-mapping; rho; spin-lock; magnetic resonance imaging; endogenous; nature contrast; black-blood; myocardium; heart; CARDIOVASCULAR MAGNETIC-RESONANCE; IN-VIVO; RELAXATION-TIME; ROTATING-FRAME; INFARCTION CHARACTERIZATION; ARTICULAR-CARTILAGE; CONTRAST-MEDIA; MRI; T-1; ENHANCEMENT;
D O I
10.1097/RLI.0000000000000261
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: In this study, we propose a method to acquire high spatial-resolution T-1 rho-maps, which allows bright and black-blood imaging, in a single breath-hold. To validate this innovative method, the reproducibility was tested in phantoms and volunteers. Lastly, the sensitivity and specificity for infarct detection was compared with the criterion standard late gadolinium enhancement (LGE). Methods: T-1 rho-mapping was performed using a T-1 rho-prepared balanced steady-state free precession sequence at 1.5 T and 3 T. Five images with increasing spin-lock preparation times (spin-lock = 0, 10, 20, 30, 40 milliseconds, amplitude = 500 Hz) were acquired with an interval of 3 beats. Black-blood imaging was performed using a double inversion pulse sequence. The method was tested in 2 times 10 healthy volunteers at 1.5 and 3 T and in 9 myocardial infarction patients at 1.5 T. T-1 rho-maps, and LGE images were scored for presence and extent of myocardial scarring. Results: Phantom results show that the proposed T-1 rho-mapping method gives accurate T-1 rho-values. The mean T-1 rho-relaxation time of the myocardium in healthy controls was 52.8 +/- 1.8 milliseconds at 1.5 T and 46.4 +/- 1.8 milliseconds at 3 T. In patients, the T-1 rho of infarcted myocardium was (82.4 +/- 5.2 milliseconds), and the T-1 rho of remote myocardium was (54.2 +/- 2.8 milliseconds; P < 0.0001). Sensitivity of infarct detection on a T-1 rho-map was 70%, with a specificity of 94%, compared with LGE. Conclusions: In this study, we have investigated a method to acquire high spatial-resolution T-1 rho-maps of the heart in a single breath-hold. This method proved to be reproducible and had high specificity compared with LGE and can thus be used for the endogenous detection of myocardial fibrosis in patients with ischemic cardiomyopathy.
引用
收藏
页码:505 / 512
页数:8
相关论文
共 50 条
  • [1] Endogenous Assessment of Diffuse Myocardial Fibrosis in Patients With T1ρ-Mapping
    van Oorschot, Joep W. M.
    Guclu, Fatih
    de Jong, Sanne
    Chamuleau, Steven A. J.
    Luijten, Peter R.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (01) : 132 - 138
  • [2] Endogenous assessment of chronic myocardial infarction with T1ρ-mapping in patients
    van Oorschot, Joep W. M.
    El Aidi, Hamza
    Sanne J. Jansen of Lorkeers
    Gho, Johannes M. I. H.
    Froeling, Martijn
    Visser, Fredy
    Chamuleau, Steven A. J.
    Doevendans, Pieter A.
    Luijten, Peter R.
    Leiner, Tim
    Zwanenburg, Jaco J. M.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [3] Simultaneous multislice imaging for native myocardial T1 mapping: Improved spatial coverage in a single breath-hold
    Weingaertner, Sebastian
    Moeller, Steen
    Schmitter, Sebastian
    Auerbach, Edward
    Kellman, Peter
    Shenoy, Chetan
    Akcakaya, Mehmet
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) : 462 - 471
  • [4] Single breath-hold 3D cardiac T1 mapping using through-time spiral GRAPPA
    Chen, Yong
    Lo, Wei-Ching
    Hamilton, Jesse I.
    Barkauskas, Kestutis
    Saybasili, Haris
    Wright, Katherine L.
    Batesole, Joshua
    Griswold, Mark A.
    Gulani, Vikas
    Seiberlich, Nicole
    NMR IN BIOMEDICINE, 2018, 31 (06)
  • [5] Clinical feasibility of 3D-QALAS - Single breath-hold 3D myocardial T1 and T2-mapping
    Kvernby, Sofia
    Warntjes, Marcel
    Engvall, Jan
    Carlhall, Carl-Johan
    Ebbers, Tino
    MAGNETIC RESONANCE IMAGING, 2017, 38 : 13 - 20
  • [6] Magnetic resonance fingerprinting for simultaneous renal T1 and T2*mapping in a single breath-hold
    Hermann, Ingo
    Chacon-Caldera, Jorge
    Brumer, Irene
    Rieger, Benedikt
    Weingartner, Sebastian
    Schad, Lothar R.
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 1940 - 1948
  • [7] Endogenous assessment of chronic myocardial infarction with T1ρ-mapping in patients
    Joep WM van Oorschot
    Hamza El Aidi
    Sanne J Jansen of Lorkeers
    Johannes MIH Gho
    Martijn Froeling
    Fredy Visser
    Steven AJ Chamuleau
    Pieter A Doevendans
    Peter R Luijten
    Tim Leiner
    Jaco JM Zwanenburg
    Journal of Cardiovascular Magnetic Resonance, 16
  • [8] Confounder-corrected T1 mapping in the liver through simultaneous estimation of T1, PDFF, R2* , and B1+ in a single breath-hold acquisition
    Roberts, Nathan T.
    Tamada, Daiki
    Muslu, Yavuz
    Hernando, Diego
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2186 - 2203
  • [9] Single breath-hold saturation recovery 3D cardiac T1 mapping via compressed SENSE at 3T
    Ferreira da Silva, Tiago
    Galan-Arriola, Carlos
    Montesinos, Paula
    Lopez-Martin, Gonzalo Javier
    Desco, Manuel
    Fuster, Valentin
    Ibanez, Borja
    Sanchez-Gonzalez, Javier
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2020, 33 (06) : 865 - 876
  • [10] Fat-saturated dark-blood cardiac T2 mapping in a single breath-hold
    Hu, Chenxi
    Huber, Steffen
    Nguyen, Vinh
    Baldassarre, Lauren
    Mojibian, Hamid
    Peters, Dana
    MAGNETIC RESONANCE IMAGING, 2021, 81 : 24 - 32