Cemented long-stem revision total knee arthroplasty

被引:95
|
作者
Whaley, AL [1 ]
Trousdale, RT [1 ]
Rand, JA [1 ]
Hanssen, AD [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2003年 / 18卷 / 05期
关键词
long-stem; revision total knee arthroplasty;
D O I
10.1016/S0883-5403(03)00200-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
From 1981 to 1989, 38 cemented, posterior, stabilized, revision, total knee arthroplasties (TKAs) were performed at the authors' institution using the stemmed kinematic stabilizer prosthesis of a single design. The mean clinical follow-up after the index procedure was 10.1 years. The Knee Society pain score averaged 17 points before revision and improved to 51 points at last follow-up, and the function score averaged 48 points before revision and improved to 57 at last follow-up. Ten-year component survival free of revision or removal for any reason was 96.7%; 11-year component survival free of revision for aseptic loosening was 95.7%. Cemented stem fixation in revision TKA provides good clinical results with durable fixation at an average of 10 years' follow-up.
引用
收藏
页码:592 / 599
页数:8
相关论文
共 50 条
  • [1] CEMENTED LONG-STEM REVISION TOTAL KNEE ARTHROPLASTY
    MURRAY, PB
    RAND, JA
    HANSSEN, AD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (309) : 116 - 123
  • [2] TREATMENT OF JUXTAARTICULAR NONUNION FRACTURES AT THE KNEE WITH LONG-STEM TOTAL KNEE ARTHROPLASTY
    ANDERSON, SP
    MATTHEWS, LS
    KAUFER, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (260) : 104 - 109
  • [3] Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty?
    Sathappan S. Sathappan
    Hee-Nee Pang
    Alikkal Manoj
    Thambayah Ashwin
    K. Satku
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 179 - 183
  • [4] Does stress shielding occur with the use of long-stem prosthesis in total knee arthroplasty?
    Sathappan, Sathappan S.
    Pang, Hee-Nee
    Manoj, Alikkal
    Ashwin, Thambayah
    Satku, K.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (02) : 179 - 183
  • [5] Periprosthetic fracture between a constrained total knee arthroplasty and a long-stem total hip arthroplasty - Treatment with a novel device
    Lachiewicz, Paul F.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 449 - 452
  • [6] Adverse clinical events during cemented long-stem femoral arthroplasty
    Herrenbruck, T
    Erickson, EW
    Damron, TA
    Heiner, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (395) : 154 - 163
  • [7] Cemented versus Cementless Stems in Revision Total Knee Arthroplasty
    Driesman, Adam S.
    Macaulay, William
    Schwarzkopf, Ran
    JOURNAL OF KNEE SURGERY, 2019, 32 (08) : 704 - 709
  • [8] Total Knee Arthroplasty With Long-Stem Implant: A Case Report of a Patient With Extreme Varus Deformity
    Patil, Vishal S.
    Nair, Vinod
    Todkar, Amogh
    Shah, Meet
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [9] One-stage long-stem total knee arthroplasty for arthritic knees with stress fractures
    Mittal, Amber
    Bhosale, Pradeep B.
    Suryawanshi, Ashish V.
    Purohit, Shaligram
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (02): : 199 - 203
  • [10] Stem length in revision total knee arthroplasty
    Patel A.R.
    Barlow B.
    Ranawat A.S.
    Current Reviews in Musculoskeletal Medicine, 2015, 8 (4) : 407 - 412