High-dose-rate effects in the radiolysis of water at elevated temperatures

被引:5
|
作者
Sultana, Abida [1 ,2 ]
Meesungnoen, Jintana [1 ]
Jay-Gerin, Jean-Paul [1 ]
机构
[1] Univ Sherbrooke, Fac Med & Sci Sante, Dept Med Nucl & Radiobiol, 300112e Ave Nord, Sherbrooke, PQ J1H 5N4, Canada
[2] Noakhali Sci & Technol Univ, Dept Appl Chem & Chem Engn, Noakhali 3814, Bangladesh
基金
加拿大自然科学与工程研究理事会;
关键词
liquid water; radiolysis; absorbed dose rate; linear energy transfer (LET); elevated temperatures; Monte Carlo track chemistry simulations; ENERGY-TRANSFER RADIOLYSIS; MONTE-CARLO-SIMULATION; PULSE-RADIOLYSIS; LIQUID WATER; HYDRATED ELECTRON; AQUEOUS-SOLUTIONS; HIGH-INTENSITY; HYDROGEN-PEROXIDE; PROTON TRACKS; YIELDS;
D O I
10.1139/cjc-2021-0012
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Monte Carlo track chemistry simulations were used to study the effects of high dose rates on the radical (e(aq)(-), H-center dot, and (OH)-O-center dot) and molecular (H-2 and H2O2) yields in the low linear energy transfer (LET) radiolysis of liquid water at elevated temperatures between 25 and 350 degrees C. Our simulation model consisted of randomly irradiating water with single pulses of N incident protons of 300 MeV (LET similar to 0.3 keV/lm), which penetrate at the same time perpendicular to this water within the surface of a circle. The effect of dose rate was studied by varying N. Our simulations showed that, at any given temperature, the radical products decrease with increasing dose rate and, at the same time, the molecular products increase, resulting from an increase in the inter-track, radical-radical reactions. Using the kinetics of the decay of hydrated electrons at 25 and 350 degrees C, we determined a critical time (tau(c)) for each value of N, which corresponds to the "onset" of dose-rate effects. For our irradiation model, tau(c) was inversely proportional to N for the two temperatures considered, with tau(c) at 350 degrees C shifted by an order of magnitude to shorter times compared with its values at 25 degrees C. Finally, the data obtained from the simulations for N = 2000 generally agreed with the observation that during the track stage of radiolysis, free radical yields increase, whereas molecular products decrease with increasing temperatures from 25 to 350 degrees C. The exceptions of e(aq)(-) and H-2 to this general pattern are briefly discussed.
引用
收藏
页码:594 / 602
页数:9
相关论文
共 50 条
  • [21] High-strain-rate testing of beryllium copper at elevated temperatures
    Quinlan, MF
    Hillery, MT
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 153 : 1051 - 1057
  • [22] γ-Radiolysis of benzophenone aqueous solution at elevated temperatures up to supercritical condition
    Miyazaki, T
    Katsumura, Y
    Lin, MZ
    Muroya, Y
    Kudo, H
    Asano, M
    Yoshida, M
    RADIATION PHYSICS AND CHEMISTRY, 2006, 75 (02) : 218 - 228
  • [23] Effects of seawater components on radiolysis of water at elevated temperature and subsequent integrity of fuel materials
    Wada, Yoichi
    Tachibana, Masahiko
    Watanabe, Atsushi
    Ishida, Kazushige
    Ota, Nobuyuki
    Shigenaka, Naoto
    Inagaki, Hiromitsu
    Noda, Hiroshi
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2016, 53 (06) : 809 - 820
  • [24] Low LET radiolysis escape yields for reducing radicals and H2 in pressurized high temperature water
    Sterniczuk, Marcin
    Yakabuskie, Pamela A.
    Wren, J. Clara
    Jacob, Jasmine A.
    Bartels, David M.
    RADIATION PHYSICS AND CHEMISTRY, 2016, 121 : 35 - 42
  • [25] Development of a phantom to validate high-dose-rate brachytherapy treatment planning systems with heterogeneous algorithms
    Moura, Eduardo S.
    Micka, John A.
    Hammer, Cliff G.
    Culberson, Wesley S.
    DeWerd, Larry A.
    Rostelato, Maria Elisa C. M.
    Zeituni, Carlos A.
    MEDICAL PHYSICS, 2015, 42 (04) : 1566 - 1574
  • [26] Acid spike effect in spurs/tracks of the low/high linear energy transfer radiolysis of water: potential implications for radiobiology
    Kanike, Vanaja
    Meesungnoen, Jintana
    Jay-Gerin, Jean-Paul
    RSC ADVANCES, 2015, 5 (54): : 43361 - 43370
  • [27] Ultra-high dose-rate (FLASH) radiotherapy: Generation of early, transient, strongly acidic spikes in the irradiated tumor environment
    Jay-Gerin, J-P
    CANCER RADIOTHERAPIE, 2020, 24 (04): : 332 - 334
  • [28] Temperature dependence of the Fricke dosimeter and spur expansion time in the low-LET high-temperature radiolysis of water up to 350 °C: a Monte-Carlo simulation study
    Sanguanmith, Sunuchakan
    Muroya, Yusa
    Tippayamontri, Thititip
    Meesungnoen, Jintana
    Lin, Mingzhang
    Katsumura, Yosuke
    Jay-Gerin, Jean-Paul
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (22) : 10690 - 10698
  • [29] A novel conformal superficial high-dose-rate brachytherapy device for the treatment of nonmelanoma skin cancer and keloids
    Ferreira, Clara
    Johnson, Daniel
    Rasmussen, Karl
    Leinweber, Clinton
    Ahmad, Salahuddin
    Jung, Jae Won
    BRACHYTHERAPY, 2017, 16 (01) : 215 - 222
  • [30] Molecular Dynamics Simulation Reveals a Change in the Structure of Liquid Water Near 150 °C, which May Explain Apparent Anomalies in High-Temperature Water Radiolysis
    Assomo, J. G. G. Ndongo
    Ebrahimi, S.
    Muroya, Y.
    Jay-Gerin, J-P
    Soldera, A.
    CHEMISTRY AFRICA-A JOURNAL OF THE TUNISIAN CHEMICAL SOCIETY, 2023, 6 (01): : 375 - 381