Three-dimensional teleradiology for surveillance following endovascular aortic aneurysm repair:: A feasibility study

被引:5
作者
Kaspersen, JH
Aasland, J
Leira, HO
Odegård, A
Nagelhus, B
Storset, G
Lundbom, J
Rosenlund, TT
Tjora, A
Myhre, HO
机构
[1] SINTEF Hlth Res, Trondheim, Norway
[2] Univ Trondheim Hosp, St Olavs Hosp, Dept Surg, Trondheim, Norway
[3] Univ Trondheim Hosp, St Olavs Hosp, Dept Radiol, Trondheim, Norway
[4] Levanger Hosp, Dept Radiol, Levanger, Norway
[5] Molde Hosp, Dept Radiol, Molde, Norway
[6] Norwegian Univ Sci & Technol, Dept Social & Polit Sci, N-7034 Trondheim, Norway
关键词
abdominal aortic aneurysm; stent-graft; endovascular repair; surveillance; computed tomography; teleradiology;
D O I
10.1583/04-1422.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To study the feasibility of 3-dimensional (3D) teleradiology in surveillance of patients treated with stent-grafts for abdominal aortic aneurysm (AAA). Methods: Between April 2002 and November 2003, 8 AAA patients (7 men; median age 73 years, range 62-84) with stent-grafts had follow-up computed tomograms (CT) performed at their local hospital and transmitted without loss across a broadband connection to the university hospital. On both monitors, the radiologists were presented with the complete CT axial dataset, sagittal and coronal reformatted slices, and a 3D volume-rendered reconstruction. The two radiologists were then able to simultaneously perform measurements and real-time manipulations of the axial and 3D pictures, which were discussed over the telephone or using a videoconferencing unit. Patient satisfaction, the radiologists' evaluation of the method, and the potential cost savings were explored. Results: Twelve follow-up CT scans were performed on the 8 patients. The time for transmission over the teleradiological network averaged 5 minutes, and the evaluation required 15 minutes at the university hospital. The overall technical quality of the images was rated as good by the university radiologist. In 11 studies, the stent-grafts were satisfactory, but a type III endoleak was detected in one 5.5-year-old stent-graft. Neither radiologist had a problem identifying the endoleak. Patients had confidence that the examination at the local hospital was of good quality; they all felt that they received good care and were pleased with avoiding travel to the university hospital. From the economic analysis, an annual savings of 40,000 Euros (US$52,304) was projected, mostly due to avoiding hospital stays and outpatient consultations at the university hospital. Conclusions: The experiences from this study are encouraging, but a larger series will be necessary for a thorough evaluation of 3D teleradiology as a surveillance method for aortic stent-graft patients.
引用
收藏
页码:196 / 199
页数:4
相关论文
共 50 条
  • [31] Aortoenteric fistula following endovascular abdominal aortic aneurysm repair
    White, Alexander B.
    Coffey, Dale D.
    Barzana, Daniel C.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2022, 8 (03): : 438 - 440
  • [32] Percutaneous Drainage of Aortic Aneurysm Sac Abscesses Following Endovascular Aneurysm Repair
    Pryluck, D. S.
    Kovacs, S.
    Maldonado, T. S.
    Jacobowitz, G. R.
    Adelman, M. A.
    Charles, H. C.
    Clark, T. W. I.
    VASCULAR AND ENDOVASCULAR SURGERY, 2010, 44 (08) : 701 - 707
  • [33] Thrombus distribution and changes in aneurysm size following endovascular aortic aneurysm repair
    Armon, MP
    Yusuf, SW
    Whitaker, SC
    Gregson, RHS
    Wenham, PW
    Hopkinson, BR
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (06) : 472 - 476
  • [34] Renal Dysfunction Following Elective Endovascular Aortic Aneurysm Repair
    Radak, Djodje
    Neskovic, Mihailo
    Otasevic, Petar
    Isenovic, Esma R.
    CURRENT VASCULAR PHARMACOLOGY, 2019, 17 (02) : 133 - 140
  • [35] Sizing for Endovascular Aneurysm Repair: Clinical Evaluation of a New Automated Three-Dimensional Software
    Kaladji, Adrien
    Lucas, Antoine
    Kervio, Gaelle
    Haigron, Pascal
    Cardon, Alain
    ANNALS OF VASCULAR SURGERY, 2010, 24 (07) : 912 - 920
  • [36] Endovascular repair of recurrent thoracoabdominal aortic aneurysm
    Khoury, M
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 : 106 - 111
  • [37] Endovascular repair of abdominal aortic aneurysm: An update
    May, J
    ANZ JOURNAL OF SURGERY, 2002, 72 (12) : 908 - 909
  • [38] Endovascular repair of the ruptured abdominal aortic aneurysm
    Norgren, L.
    Larzon, T.
    SCANDINAVIAN JOURNAL OF SURGERY, 2008, 97 (02) : 178 - 181
  • [39] Successful Endovascular Aneurysm Repair for a Ruptured Abdominal Aortic Aneurysm
    Kim, Jang Yong
    Park, Keun Myoung
    Jeon, Yong Sun
    Cho, Soon Gu
    Hong, Kee-Chun
    JOURNAL OF THE KOREAN SURGICAL SOCIETY, 2009, 77 (06): : 429 - 433
  • [40] Proposed Algorithm for Endovascular Aneurysm Repair Surveillance: A Call for Further Research on Personalized Surveillance
    Antoniou, George A.
    Torella, Francesco
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (06) : 968 - 970