Structural and mechanical characterisation of the peri-prosthetic tissue surrounding loosened hip prostheses. An explorative study

被引:7
作者
Moerman, Astrid [1 ,2 ]
Zadpoor, Amir A. [2 ]
Oostlander, Angela [1 ]
Schoeman, Monique [1 ]
Moshtagh, Parisa Rahnamay [2 ,3 ]
Pouran, Behdad [2 ,3 ]
Valstar, Edward [1 ,2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, Leiden, Netherlands
[2] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, Delft, Netherlands
[3] Univ Med Ctr Utrecht, Dept Orthopaed, Utrecht, Netherlands
关键词
Hip replacement; Peri-prosthetic tissue; Histology; Tissue biomechanics; ATOMIC-FORCE MICROSCOPY; ARTICULAR-CARTILAGE; POLARIZED-LIGHT; ELASTIC-MODULUS; COLLAGEN; REPLACEMENT; INTERFACE; NANOINDENTATION; ORGANIZATION; MEMBRANE;
D O I
10.1016/j.jmbbm.2016.04.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Very little is known about the structure and properties of peri-prosthetic fibrous tissue that is found around loose orthopaedic implants. We describe a method for characterizing the structural organisation (histology, confocal microscopy) as well as the nano-and micro scale mechanical behaviour (atomic force microscopy, nanoindentation) of peri-prosthetic fibrous tissue. The tissue was collected from 11 patients undergoing revision surgery due to aseptic loosening. Sirius Red and Movat histological staining procedures indicated that the tissue mainly consists of collagen fibres and ground substance. However, large inter-and intra-patient variations in the relative proportions of these tissue components were found, as well as in collagen fibre orientation and possibly also maturation. The nano-scale Young's moduli ranged from 0-950 kPa, but showed large inter-patient variability. When the results per sample were presented in a probability density function, we could roughly discriminate one peak in the 0-100 kPa range and/or one peak in the 100-500 Pa range. These nano-scale moduli seem to respectively present the mechanical properties of glycosaminoglycan (GAG) and collagen molecules. The majority of the micro-scale Young's moduli ranged between 0.5 and 2.0 kPa for all samples. This explorative study provides new insights in (the variations of) structural organisation and mechanical properties of peri-prosthetic tissue. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:456 / 467
页数:12
相关论文
共 2 条
  • [1] The economic impact of surgically treated peri-prosthetic hip fractures on a university teaching hospital in Wales 7.5-year study
    Jones, Andrew R.
    Williams, Tim
    Paringe, Vishal
    White, Simon P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (02): : 428 - 431
  • [2] Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography
    Tang, Hao
    Huang, Xingjian
    Cheng, Xiaoguang
    Yang, Dejin
    Huang, Yong
    Zhou, Yixin
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (09) : 1786 - 1800