Real-time reduction of motion artefacts using k-space weighting in magnetic resonance imaging

被引:2
作者
Sinkus, R [1 ]
Bornert, P [1 ]
机构
[1] Philips Res Labs, Div Tech Syst, D-22335 Hamburg, Germany
关键词
abdominal MRI; artefact reduction; diminishing variance algorithm; k-space weighting; motion adapted gating; respiratory motion;
D O I
10.1016/S0165-5817(98)00009-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
An improved version of motion-adapted gating useful in MR imaging is presented. Compared to other gating approaches, this advances method shows an improved ability to suppress motion artefacts at a reduced scan time. It is based on a k-space dependent weighting function and a realtime system feedback. During MR data acquisition patient motion is monitored and only those profiles are accepted whose respiratory motion induced displacements are below a pre-defined threshfold (gating) function. The displacements are measured relative to a reference position, which is automatically determined during the initial phase of the MR scan. While MR data are acquired, the object motion is statistically analysed in parallel by calculating the histogram of the displacement distribution for consecutive time intervals. This information can be used to interfere with the measurement process in the case that motion statistics changes during the scan. Initial in-vivo results are presented and compared to conventional techniques.
引用
收藏
页码:339 / 352
页数:14
相关论文
共 15 条
  • [1] RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING
    BAILES, DR
    GILDERDALE, DJ
    BYDDER, GM
    COLLINS, AG
    FIRMIN, DN
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) : 835 - 838
  • [2] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [3] HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
  • [4] FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES
    HAASE, A
    FRAHM, J
    MATTHAEI, D
    HANICKE, W
    MERBOLDT, KD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) : 258 - 266
  • [5] RAPID NMR CARDIOGRAPHY WITH A HALF-ECHO M-MODE METHOD
    HARDY, CJ
    PEARLMAN, JD
    MOORE, JR
    ROEMER, PB
    CLINE, HE
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) : 868 - 874
  • [6] A MONITORING, FEEDBACK, AND TRIGGERING SYSTEM FOR REPRODUCIBLE BREATH-HOLD MR-IMAGING
    LIU, YL
    RIEDERER, SJ
    ROSSMAN, PJ
    GRIMM, RC
    DEBBINS, JP
    EHMAN, RL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (04) : 507 - 511
  • [7] MULTI-PLANAR IMAGE-FORMATION USING NMR SPIN ECHOES
    MANSFIELD, P
    [J]. JOURNAL OF PHYSICS C-SOLID STATE PHYSICS, 1977, 10 (03): : L55 - L58
  • [8] PROKSA R, 1995, P SMR 3 ANN M NIC
  • [9] THE DIMINISHING VARIANCE ALGORITHM FOR REAL-TIME REDUCTION OF MOTION ARTIFACTS IN MRI
    SACHS, TS
    MEYER, CH
    IRARRAZABAL, P
    HU, BS
    NISHIMURA, DG
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) : 412 - 422
  • [10] SINKUS R, 1997, P ISMRM 5 ANN M VANC