Liquid chromatography-tandem mass spectrometry method for quantification of gentamicin and its individual congeners in serum and comparison results with two immunoanalytical methods (fluorescence polarization immunoassay and chemiluminiscent microparticle immunoassay)

被引:5
|
作者
Brozmanova, Hana [1 ,2 ]
Urinovska, Romana [1 ,2 ]
Safarcik, Kristian [3 ,4 ]
Vsiansky, Frantisek [3 ]
Kacirova, Ivana [1 ,2 ]
Grundmann, Milan [1 ]
机构
[1] Univ Ostrava, Fac Med, Inst Clin Pharmacol, Syllabova 19, Ostrava 70300, Czech Republic
[2] Univ Hosp Ostrava, Dept Clin Pharmacol, Dept Lab Med, 17 Listopadu 1790, Ostrava 70852, Czech Republic
[3] Univ Hosp Ostrava, Dept Clin Biochem, Dept Lab Med, 17 Listopadu 1790, Ostrava 70852, Czech Republic
[4] Univ Ostrava, Fac Med, Dept Biomed Sci, Syllabova 19, Ostrava 70300, Czech Republic
关键词
Total gentamicin concentration; LC-MS/MS; Fluorescence polarization immunoassay; Chemiluminiscence microparticle immunoassay; Therapeutic drug monitoring; PLASMA; VANCOMYCIN; AMIKACIN; TISSUES; SAMPLES; URINE;
D O I
10.1016/j.cca.2021.07.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Total gentamicin is a sum of five congeners C1, C1a, C2, C2a and minor C2b, which differ from each other in their methylation on the purpurosamine ring. Liquid chromatography with mass detection (LC-MS/MS) and specified calibration material enables the concentration of total gentamicin and its individual congeners to be analysed. Methods: 50 mu L serum was precipitated with acetonitrile in the presence of 0.5 mol/L formic acid. A RP BEH C18 1.7 mu m 2.1x50 mm column maintained at 30 degrees C and tobramicin as the internal standard were used. Mass detection was performed in positive electrospray. The gentamicin results were compared with fluorescence polarization immunoassay (FPIA) and chemiluminiscent microparticle immunoassay (CMIA). Passing-Bablock regression analysis and Bland-Altman analysis were used. Results: Calibration curves for individual gentamicin congeners were linear with correlation coefficients between 0.997 and 0.998. Recovery was 91.6-102.0% and the coefficients of variation 1.4-8.4%. The total gentamicin concentration was compared with immunoassay FPIA (LC-MSgen = 0.9798xPFIA(gen)) and CMIA (LC MSgen = 0.9835xCMIA(gen)) both with significant correlation (p < 0.001). Conclusion: The LC-MS/MS method is fast and precise and can be applied to routine TDM in patients. Comparing it to immunoassays makes it possible to measure concentration of gentamicin congeners, which may be important in the case of their different pharmacokinetics.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [41] Comparison of liquid chromatography-tandem mass spectrometry with a commercial enzyme-multiplied immunoassay for the determination of plasma MPA in renal transplant recipients and consequences for therapeutic drug monitoring
    Prémaud, A
    Rousseau, A
    Le Meur, Y
    Lachâtre, G
    Marquet, P
    THERAPEUTIC DRUG MONITORING, 2004, 26 (06) : 609 - 619
  • [42] Development and validation of two bioanalysis methods for the determination of etimicin in human serum and urine by liquid chromatography-tandem mass spectrometry: Applications to a human pharmacokinetic and breakpoint study
    Cui, Xinge
    Zheng, Xin
    Ren, Jianwei
    Liu, Hongzhong
    Jia, Yuan
    Wu, Aiguo
    Han, Xiaohong
    FRONTIERS IN PHARMACOLOGY, 2023, 14
  • [43] Performance characteristics and patient comparison of the ARK Diagnostics levetiracetam immunoassay with an ultra-high performance liquid chromatography with tandem mass spectrometry detection method
    Juenke, JoEtta M.
    McGraw, J. Paul
    McMillin, Gwendolyn A.
    Johnson-Davis, Kamisha L.
    CLINICA CHIMICA ACTA, 2012, 413 (3-4) : 529 - 531
  • [44] Comparison of High Performance Liquid Chromatography with Fluorescence Detector and with Tandem Mass Spectrometry Methods for Detection and Quantification of Ochratoxin A in Green and Roasted Coffee Beans
    da Costa Cunha Bandeira, Raquel Duarte
    Uekane, Thais Matsue
    da Cunha, Carolina Passos
    Rodrigues, Janaina Marques
    Campino de la Cruz, Marcus Henrique
    de Oliveira Godoy, Ronoel Luiz
    Fioravante, Andreia de Lima
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2013, 56 (06) : 911 - 920
  • [45] A comparison of liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-multiplied immunoassay technique (EMIT) for the determination of the cyclosporin A concentration in whole blood from Chinese patients
    Li, Wenlong
    Li, Rong
    Liu, Huanjun
    Guo, Xi
    Shaikh, Abdul Sami
    Li, Pingli
    Wang, Benjie
    Guo, Ruichen
    Zhang, Rui
    BIOSCIENCE TRENDS, 2017, 11 (04) : 475 - 482
  • [46] A simple and rapid liquid chromatography-tandem mass spectrometry method for the simultaneous determination of 15 bile acids in human serum and its application to patients with decompensated cirrhosis
    Li, Ying
    Cui, Li
    Liu, Mingli
    Zhao, Furong
    Sun, Hongzhi
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (06)
  • [47] Comparison of ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and enzyme-multiplied immunoassay technique (EMIT) for quantification of voriconazole plasma concentration from Chinese patients
    Yu, Mingjie
    Yang, Jun
    Xiong, Lirong
    Zhan, Shipeng
    Cheng, Lin
    Chen, Yongchuan
    Liu, Fang
    HELIYON, 2023, 9 (11)
  • [48] A Rapid Method for Determination of Serum Methotrexate Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Therapeutic Drug Monitoring
    Tripathy, Naresh Kumar
    Mishra, Shravan Kumar
    Nathan, Gopi
    Srivastava, Shreya
    Gupta, Anshul
    Lingaiah, Raghavendra
    JOURNAL OF LABORATORY PHYSICIANS, 2023, 15 (03) : 344 - 353
  • [49] A validated simultaneous quantification method for vonoprazan (TAK-438F) and its 4 metabolites in human plasma by the liquid chromatography-tandem mass spectrometry
    Yoneyama, Tomoki
    Teshima, Koichiro
    Jinno, Fumihiro
    Kondo, Takahiro
    Asahi, Satoru
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1015 : 42 - 49
  • [50] Development and validation of a liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of tamoxifen, anastrozole, and letrozole in human plasma and its application to a clinical study
    Beer, Beate
    Schubert, Birthe
    Oberguggenberger, Anne
    Meraner, Verena
    Hubalek, Michael
    Oberacher, Herbert
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (04) : 1791 - 1800