Biomechanical analysis of supra-acetabular insufficiency fracture using finite element analysis

被引:3
作者
Tanaka, Hidetatsu [1 ]
Yamako, Go [2 ]
Kurishima, Hiroaki [1 ]
Yamashita, Shutaro [2 ]
Mori, Yu [1 ]
Chiba, Daisuke [1 ]
Chosa, Etsuo [3 ]
Itoi, Eiji [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Orthopaed Surg, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
[2] Univ Miyazaki, Fac Engn, Dept Mech Design Syst, 1-1 Gakuen Kibana Dai Nishi, Miyazaki 8892192, Japan
[3] Univ Miyazaki, Dept Med Sensory & Motor Organs, Div Orthoped Surg, Fac Med, Miyazaki 8891692, Japan
基金
日本学术振兴会;
关键词
HIP-JOINT; HUMAN PELVIS; BONE; MODELS;
D O I
10.1016/j.jos.2018.04.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Supra-acetabular insufficiency fractures (SAIFs) occur in the upper acetabulum and are rare compared with insufficiency sacral, femoral head, or ischial fractures. However, SAIFs are known to occur in low grade trauma, and the underlying mechanism is still remained unclear. Methods: We performed biomechanical analysis using finite element analysis to clarify the mechanisms underlying the development of SAIFs. Patient-specific models and bone mineral density (BMD) were derived from pelvic computed tomography data from two patients with SAIF (unaffected side) and two healthy young adults. The bone was assumed to be an isotropic, linearly elastic body. We assigned Young's modulus of each element to the pelvis based on the BMD, and reported the relationships for BMD-modulus. Clinically relevant loading conditions-walking and climbing stairs-were applied to the models. We compared the region of failure risk in each acetabulum using a maximum principal strain criterion. Results: The average supra-acetabular BMD was less than that of the hemi-pelvis and femoral head, but was higher than that of the femoral neck and greater trochanter. Greater minimum principal strain was concentrated in the supra-acetabular portion in both the SAIF and healthy models. In the SAIF models, the higher region of the failure risk matched the fracture site on the acetabulum. Conclusions: Relative fragility causes compressive strain to concentrate in the upper acetabulum when walking and climbing stairs. When presented with a patient complaining of hip pain without apparent trauma or abnormal X-ray findings, physicians should consider the possibility of SAIF and perform magnetic resonance imaging for the diagnosis of SAIF. (C) 2018 Published by Elsevier B.V. on behalf of The Japanese Orthopaedic Association.
引用
收藏
页码:825 / 833
页数:9
相关论文
共 50 条
  • [41] Biomechanical evaluation of lumbar spondylolysis repair with various fixation options: A finite element analysis
    Ye, Yuchen
    Jin, Shichang
    Zou, Yang
    Fang, Yuekun
    Xu, Panpan
    Zhang, Zhili
    Wu, Nan
    Zhang, Changchun
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [42] Influence of Different Boundary Conditions in Finite Element Analysis on Pelvic Biomechanical Load Transmission
    Hu, Pan
    Wu, Tao
    Wang, Hui-zhi
    Qi, Xin-zheng
    Yao, Jie
    Cheng, Xiao-dong
    Chen, Wei
    Zhang, Ying-ze
    ORTHOPAEDIC SURGERY, 2017, 9 (01) : 115 - 122
  • [43] Biomechanical analysis of vertebral wedge deformity in elderly women with quantitative CT-based finite element analysis
    Liu, Jing
    Cheng, Xiaodong
    Wang, Yan
    Zhang, Ping
    Gao, Lei
    Yang, Xingyuan
    He, Shaoqiang
    Liu, Ying
    Zhang, Wei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [44] Finite element analysis of the effect of porosity on biomechanical behaviour of functionally graded dental implant
    Elleuch, Sameh
    Jrad, Hanen
    Wali, Mondher
    Dammak, Fakhreddine
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2023,
  • [45] Establishing the biomechanical properties of the pelvic soft tissues through an inverse finite element analysis using magnetic resonance imaging
    Silva, M. E. T.
    Brandao, S.
    Parente, M. P. L.
    Mascarenhas, T.
    Jorge, R. M. Natal
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (04) : 298 - 309
  • [46] ACETABULAR LOAD-TRANSFER AND MECHANICAL STABILITY: A FINITE ELEMENT ANALYSIS COMPARING DIFFERENT CEMENTLESS SOCKETS
    Pakvis, D. F. M.
    Janssen, D.
    Schreurs, B. W.
    Verdonschot, N.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2014, 14 (05)
  • [47] The risk of tibial eminence avulsion fracture with bi-unicondylar knee arthroplasty A FINITE ELEMENT ANALYSIS
    Stoddart, J. C.
    Garner, A.
    Tuncer, M.
    Cobb, J. P.
    van Arkel, R. J.
    BONE & JOINT RESEARCH, 2022, 11 (08): : 575 - 584
  • [48] Biomechanical Factors Associated with Mandibular Cantilevers: Analysis with Three-Dimensional Finite Element Models
    Gonda, Tomoya
    Yasuda, Daiisa
    Ikebe, Kazunori
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : E275 - E282
  • [49] Biomechanical analysis of the lumbar spine on facet joint force and intradiscal pressure - a finite element study
    Kuo, Ching-Sung
    Hu, Hsuan-Teh
    Lin, Ruey-Mo
    Huang, Kuo-Yuan
    Lin, Po-Chun
    Zhong, Zheng-Cheng
    Hseih, Mu-Lin
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [50] Biomechanical response of lumbar intervertebral disc in daily sitting postures: a poroelastic finite element analysis
    Zheng, Liang-dong
    Cao, Yu-ting
    Yang, Yi-ting
    Xu, Meng-lei
    Zeng, Hui-zi
    Zhu, Shi-jie
    Candito, Antonio
    Chen, Yuhang
    Zhu, Rui
    Cheng, Li-ming
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (16) : 1941 - 1950