The Influence of Verification Jig on Framework Fit for Nonsegmented Fixed Implant-Supported Complete Denture

被引:45
作者
Ercoli, Carlo [1 ]
Geminiani, Alessandro [2 ]
Feng, Changyong [3 ]
Lee, Heeje [1 ]
机构
[1] Univ Rochester, Div Prosthodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[2] Univ Rochester, Div Periodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[3] Univ Rochester, Dept Biostat & Computat Biol, Rochester, NY 14620 USA
关键词
computer aided prosthetic designs; dental casting technique; instrumentation; dental implants; dental prosthesis; dental prosthesis design; methods; implant-supported; implants restoration; IMPRESSION TECHNIQUES; DENTAL IMPLANTS; PROSTHESES; ACCURACY; BONE; SYSTEM; CAST;
D O I
10.1111/j.1708-8208.2011.00425.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. Materials and Methods: This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. Results: When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Conclusions: Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture.
引用
收藏
页码:e188 / e195
页数:8
相关论文
共 50 条
[31]   Factors associated with edentulous patients' willingness about implant-supported complete denture: a multivariate analysis [J].
Verissimo, Aretha Heitor ;
Ribeiro, Anne Kaline Claudino ;
de Medeiros, Annie Karoline Bezerra ;
de Melo, Laercio Almeida ;
da Fonte Porto Carreiro, Adriana .
CLINICAL ORAL INVESTIGATIONS, 2022, 26 (02) :1835-1842
[32]   Repair of a Multiple Implant-Supported Fixed Superstructure With a Metal-Ceramic Resin-Bonded Fixed Partial Denture: A Clinical Report [J].
Hagiwara, Yoshiyuki ;
Narita, Tatsuya ;
Araki, Masao ;
Sawada, Kunihiko ;
Nakajima, Kiyoshi .
JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 :371-374
[33]   Factors associated with edentulous patients’ willingness about implant-supported complete denture: a multivariate analysis [J].
Aretha Heitor Veríssimo ;
Anne Kaline Claudino Ribeiro ;
Annie Karoline Bezerra de Medeiros ;
Laércio Almeida de Melo ;
Adriana da Fonte Porto Carreiro .
Clinical Oral Investigations, 2022, 26 :1835-1842
[34]   Management of an Implant-Supported Fixed Partial Denture in the Esthetic Zone in a Patient With a Very Limited Mouth Opening: A Case Report [J].
Silvestri, Frederic ;
Stephan, Thomas ;
Mansuy, Charlotte ;
Mense, Chloe .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
[35]   Misfit of Implant Fixed Complete Denture Following Computer-Guided Surgery [J].
Oyama, Kotaro ;
Kan, Joseph Y. K. ;
Kleinman, Alejandro S. ;
Runcharassaeng, Kitichai ;
Lozada, Jaime L. ;
Goodacre, Charles J. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (01) :124-130
[36]   A new material for fixed implant-supported rehabilitations [J].
Di Iorio, E. ;
Berardini, M. .
DENTAL CADMOS, 2016, 84 (05) :320-325
[37]   Effects of attachment type and palatal coverage on oral perception and patient satisfaction in maxillary implant-supported complete denture patients [J].
Kilic, K. ;
Kurtulus, I. L. ;
Eraslan, R. ;
Zararsiz, G. ;
Kesim, B. .
NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (05) :669-674
[38]   Vertical Microgap and Passivity of Fit of Three-Unit Implant-Supported Frameworks Fabricated Using Different Techniques [J].
Berejuk, Halina Massignan ;
Shimizu, Roberto Hideo ;
de Mattias Sartori, Ivete Aparecida ;
Valgas, Laiz ;
Tiossi, Rodrigo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (05) :1064-1070
[39]   Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework [J].
Muhsin S.A. ;
Mohammed E.K. ;
Bander K. .
Journal of Long-Term Effects of Medical Implants, 2024, 34 (04) :33-47
[40]   Intraoral Luting: Modified Prosthetic Design to Achieve Passivity, Precision of Fit, and Esthetics for a Cement-Retained, Implant-Supported Metal-Resin-Fixed Complete Denture [J].
Longoni, Salvatore ;
Sartori, Matteo ;
Maroni, Italo ;
Baldoni, Marco .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (02) :166-170