The Influence of Verification Jig on Framework Fit for Nonsegmented Fixed Implant-Supported Complete Denture

被引:45
作者
Ercoli, Carlo [1 ]
Geminiani, Alessandro [2 ]
Feng, Changyong [3 ]
Lee, Heeje [1 ]
机构
[1] Univ Rochester, Div Prosthodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[2] Univ Rochester, Div Periodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[3] Univ Rochester, Dept Biostat & Computat Biol, Rochester, NY 14620 USA
关键词
computer aided prosthetic designs; dental casting technique; instrumentation; dental implants; dental prosthesis; dental prosthesis design; methods; implant-supported; implants restoration; IMPRESSION TECHNIQUES; DENTAL IMPLANTS; PROSTHESES; ACCURACY; BONE; SYSTEM; CAST;
D O I
10.1111/j.1708-8208.2011.00425.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. Materials and Methods: This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. Results: When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Conclusions: Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture.
引用
收藏
页码:e188 / e195
页数:8
相关论文
共 50 条
[21]   Peri-Implant Diseases and Biologic Complications at Implant-Supported Fixed Dental Prostheses in Partially Edentulous Patients [J].
Tsigarida, Alexandra ;
Chochlidakis, Konstantinos ;
Fraser, David ;
Lampraki, Evangelia ;
Einarsdottir, Erna R. ;
Barmak, Abdul Basir ;
Papaspyridakos, Panos ;
Ercoli, Carlo .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (05) :429-435
[22]   Simplified fabrication of an implant-supported framework with luted abutment cylinders [J].
Stumpel, Lambert J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (01) :5-9
[23]   Digital analysis of fabrication accuracy and fit in additively and subtractively manufactured implant-supported fixed complete dentures [J].
Maldonado, Paola ;
Donmez, Mustafa Borga ;
Guven, Mehmet Esad ;
Schimmel, Martin ;
Revilla-Leon, Marta ;
Cakmak, Gulce ;
Yilmaz, Burak .
JOURNAL OF DENTISTRY, 2024, 150
[24]   A Stereophotogrammetry Face Study Between Dentate and Edentulous Adults Rehabilitated with Either a Conventional Complete or an Implant-Supported Fixed Complete Denture [J].
Pucciarelli, Maria Giulia R. ;
Toyoshima, Guilherme Hideki L. ;
Neppelenbroek, Karin H. ;
Sforza, Chiarella ;
Oliveira, Thais M. ;
Soares, Simone .
EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2023, 31 (04) :407-415
[25]   A Method for Fabrication of Implant-Supported Fixed Partial Dentures [J].
Zafiropoulos, Gregory-George ;
Hoffmann, Oliver ;
Deli, Georgio .
JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) :271-279
[26]   Treatment of a mandibular discontinuity defect by using a fibula free flap and an implant-supported fixed complete denture fabricated with a PEKK framework: A clinical report [J].
Oh, Kyung Chul ;
Park, Ji-Hyun ;
Lee, Joon-hee ;
Moon, Hong Seok .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06) :1021-1024
[27]   The Precision of Fit of Cast and Milled Full-Arch Implant-Supported Restorations [J].
Paniz, Gianluca ;
Stellini, Edoardo ;
Meneghello, Roberto ;
Cerardi, Andrea ;
Gobbato, Edoardo Alvise ;
Bressan, Eriberto .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) :687-693
[28]   Fit and Stability of Screw-Retained Implant-Supported Frameworks Under Masticatory Simulation: Influence of Cylinder Type [J].
Brilhante Bhering, Claudia Lopes ;
Vieira Marques, Isabella da Silva ;
Ferreira Koyama Takahashi, Jessica Mie ;
Ricardo Barao, Valentim Adelino ;
Xediek Consani, Rafael Leonardo ;
Mesquita, Marcelo Ferraz .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (06) :459-465
[29]   The Use of Zirconia for Implant-Supported Fixed Complete Dental Prostheses: A Narrative Review [J].
Cinquini, Chiara ;
Alfonsi, Fortunato ;
Marchio, Vincenzo ;
Gallo, Francesco ;
Zingari, Francesco ;
Bolzoni, Alessandro Remigio ;
Romeggio, Stefano ;
Barone, Antonio .
DENTISTRY JOURNAL, 2023, 11 (06)
[30]   Impact of Replacing Conventional Complete Dentures with Implant-Supported Fixed Complete Dentures [J].
Compagnoni, Marco Antonio ;
Paeari, Andre Gustavo ;
Rodriguez, Larissa Santana ;
Giro, Gabriela ;
Mendoza Marin, Danny Omar ;
Pero, Ana Carolina .
INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (06) :833-839