The Influence of Verification Jig on Framework Fit for Nonsegmented Fixed Implant-Supported Complete Denture

被引:41
作者
Ercoli, Carlo [1 ]
Geminiani, Alessandro [2 ]
Feng, Changyong [3 ]
Lee, Heeje [1 ]
机构
[1] Univ Rochester, Div Prosthodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[2] Univ Rochester, Div Periodont, Eastman Inst Oral Hlth, Sch Med & Dent, Rochester, NY 14620 USA
[3] Univ Rochester, Dept Biostat & Computat Biol, Rochester, NY 14620 USA
关键词
computer aided prosthetic designs; dental casting technique; instrumentation; dental implants; dental prosthesis; dental prosthesis design; methods; implant-supported; implants restoration; IMPRESSION TECHNIQUES; DENTAL IMPLANTS; PROSTHESES; ACCURACY; BONE; SYSTEM; CAST;
D O I
10.1111/j.1708-8208.2011.00425.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this retrospective study was to assess if there was a difference in the likelihood of achieving passive fit when an implant-supported full-arch prosthesis framework is fabricated with or without the aid of a verification jig. Materials and Methods: This investigation was approved by the University of Rochester Research Subject Review Board (protocol #RSRB00038482). Thirty edentulous patients, 49 to 73 years old (mean 61 years old), rehabilitated with a nonsegmented fixed implant-supported complete denture were included in the study. During the restorative process, final impressions were made using the pickup impression technique and elastomeric impression materials. For 16 patients, a verification jig was made (group J), while for the remaining 14 patients, a verification jig was not used (group NJ) and the framework was fabricated directly on the master cast. During the framework try-in appointment, the fit was assessed by clinical (Sheffield test) and radiographic inspection and recorded as passive or nonpassive. Results: When a verification jig was used (group J, n = 16), all frameworks exhibited clinically passive fit, while when a verification jig was not used (group NJ, n = 14), only two frameworks fit. This difference was statistically significant (p < .001). Conclusions: Within the limitations of this retrospective study, the fabrication of a verification jig ensured clinically passive fit of metal frameworks in nonsegmented fixed implant-supported complete denture.
引用
收藏
页码:e188 / e195
页数:8
相关论文
共 50 条
  • [1] A Luting Technique for Passive Fit of Implant-Supported Fixed Dentures
    Menini, Maria
    Dellepiane, Elena
    Pera, Paolo
    Bevilacqua, Marco
    Pesce, Paolo
    Pera, Francesco
    Tealdo, Tiziano
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (01): : 77 - 82
  • [2] In-office fabrication of a definitive cast and duplication of an interim implant-supported fixed acrylic resin complete denture
    Stumpel, Lambert J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (02) : 135 - 139
  • [3] Accuracy of the Different Materials Used to Fabricate a Verification Jig of Implant-Supported Fixed Complete Dental Prostheses: An In Vitro Study
    Aljohani, Mawaddah S.
    Bukhari, Heba A.
    Alshehri, Mayar
    Alamoudi, Ahmed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [4] Preload evaluation of 2 implant-supported fixed partial denture abutment designs
    Alzoubi, Fawaz M.
    Sabti, Mohammad
    Alsarraf, Esra
    Alshahrani, Faris A.
    Sadowsky, Steven J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05) : 1067.e1 - 1067.e6
  • [5] Marginal Fit of Implant-Supported All-Ceramic Zirconia Frameworks
    Zaghloul, Hanaa Hassan
    Younis, Jihan Farouk
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (04) : 417 - 424
  • [6] The Influence of Connection on the Microleakage Development of Implant-Supported Fixed Bridges
    von Maltzahn, Nadine Freifrau
    Altmayer, Niels
    Kommerein, Nadine
    Stiesch, Meike
    Kohorst, Philipp
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2021, 29 (02) : 112 - 118
  • [7] Stress Analysis of Implant-Supported Removable Partial Denture with Anterior Fixed Prostheses and Conventional Implant-Supported Overdentures in the Edentulous Mandible
    Ozel, Gulsum Sayin
    Ozyilmaz, Ozgun Yusuf
    Inan, Ozgur
    JOURNAL OF ADVANCED ORAL RESEARCH, 2022, 13 (01) : 43 - 52
  • [8] A technique to guide replacement of multiunit abutments supporting an existing implant-supported fixed complete denture
    Hess, Timothy A.
    Van Ramos, Jr
    Buglione, Dana
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03) : 270 - 273
  • [9] Evaluation of two implant-supported fixed partial denture abutment designs: Influence on screw surface characteristics
    Alzoubi, Fawaz M. M.
    Sabti, Mohammad
    Alsarraf, Esra
    Alshahrani, Faris A. A.
    Sadowsky, Steven J. J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (05): : 443 - 451
  • [10] Postmortem evaluation of mandibular implant-supported fixed complete denture after 30 years of service
    Seong, Wook-Jin
    Lee, James
    Delima, Luis
    Prasad, Hari S.
    Conrad, Heather J.
    Tarnow, Dennis
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04) : 489 - 494