Prediction of permeability of regular scaffolds for skeletal tissue engineering: A combined computational and experimental study

被引:178
作者
Truscello, S. [1 ,3 ]
Kerckhofs, G. [2 ,3 ]
Van Bael, S. [1 ,3 ]
Pyka, G. [2 ,3 ]
Schrooten, J. [2 ,3 ]
Van Oosterwyck, H. [1 ,3 ]
机构
[1] Katholieke Univ Leuven, Div Biomech & Engn Design, B-3001 Heverlee, Belgium
[2] Katholieke Univ Leuven, Dept Met & Mat Engn, B-3001 Heverlee, Belgium
[3] Katholieke Univ Leuven, Div Skeletal Tissue Engn Leuven, B-3000 Louvain, Belgium
基金
比利时弗兰德研究基金会;
关键词
Bone tissue engineering; Computational fluid dynamics; Scaffold; Laser manufacturing; MICRO-CT; BONE; FLOW;
D O I
10.1016/j.actbio.2011.12.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Scaffold permeability is a key parameter combining geometrical features such as pore shape, size and interconnectivity, porosity and specific surface area. It can influence the success of bone tissue engineering scaffolds, by affecting oxygen and nutrient transport, cell seeding efficiency, in vitro three-dimensional (3D) cell culture and, ultimately, the amount of bone formation. An accurate and efficient prediction of scaffold permeability would be highly useful as part of a scaffold design process. The aim of this study was (i) to determine the accuracy of computational fluid dynamics (CFD) models for prediction of the permeability coefficient of three different regular Ti6Al4V scaffolds (each having a different porosity) by comparison with experimentally measured values and (ii) to verify the validity of the semi-empirical Kozeny equation to calculate the permeability analytically. To do so, five CFD geometrical models per scaffold porosity were built, based on different geometrical inputs: either based on the scaffold's computer-aided design (CAD) or derived from 3D microfocus X-ray computed tomography (micro-CT) data of the additive manufactured (AM) scaffolds. For the latter the influence of the spatial image resolution and the image analysis algorithm used to determine the scaffold's architectural features on the predicted permeability was analysed. CFD models based on high-resolution micro-CT images could predict the permeability coefficients of the studied scaffolds: depending on scaffold porosity and image analysis algorithm, relative differences between measured and predicted permeability values were between 2% and 27%. Finally, the analytical Kozeny equation was found to be valid. A linear correlation between the ratio Phi(3)/S-5(2) and the permeability coefficient k was found for the predicted (by means of CFD) as well as measured values (relative difference of 16.4% between respective Kozeny coefficients), thus resulting in accurate and efficient calculation of the permeability of regular AM scaffolds. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1648 / 1658
页数:11
相关论文
共 41 条
[1]   Microcellular polyHIPE polymer supports osteoblast growth and bone formation in vitro [J].
Akay, G ;
Birch, MA ;
Bokhari, MA .
BIOMATERIALS, 2004, 25 (18) :3991-4000
[2]  
[Anonymous], 2009, SOIL MECH FDN ENG
[3]   Tissue engineered bone: Measurement of nutrient transport in three-dimensional matrices [J].
Botchwey, EA ;
Dupree, MA ;
Pollack, SR ;
Levine, EM ;
Laurencin, CT .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (01) :357-367
[4]   A tissue engineering approach to bone repair in large animal models and in clinical practice [J].
Cancedda, Ranieri ;
Giannoni, Paolo ;
Mastrogiacomo, Maddalena .
BIOMATERIALS, 2007, 28 (29) :4240-4250
[5]  
Carman P.C., 1956, FLOW GASES POROUS ME
[6]   Multiscale modeling of bone tissue with surface and permeability control [J].
Coelho, Pedro Goncalves ;
Fernandes, Paulo Rui ;
Rodrigues, Helder Carrico .
JOURNAL OF BIOMECHANICS, 2011, 44 (02) :321-329
[7]   Comparison of microcomputed tomographic and microradiographic measurements of cortical bone porosity [J].
Cooper, DML ;
Matyas, JR ;
Katzenberg, MA ;
Hallgrimsson, B .
CALCIFIED TISSUE INTERNATIONAL, 2004, 74 (05) :437-447
[8]  
Darcy H., 1856, The Public Fountains of the City of Dijon
[9]   Bi-Modular Flow Characterization in Tissue Engineering Scaffolds Using Computational Fluid Dynamics and Particle Imaging Velocimetry [J].
De Boodt, Sebastian ;
Truscello, Silvia ;
Ozcan, Sezin Eren ;
Leroy, Toon ;
Van Oosterwyck, Hans ;
Berckmans, Daniel ;
Schrooten, Jan .
TISSUE ENGINEERING PART C-METHODS, 2010, 16 (06) :1553-1564
[10]  
Dennis J E, 1992, Cell Transplant, V1, P23